Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

The Rochester Conferences on Coherence and Quantum Optics and the Quantum Information and Measurement meeting

Dispersion-cancellation in a classical interferometer

Kevin J. Resch, Prabakar Puvanathasan, Jeff S. Lundeen, Morgan W. Mitchell, Kostadinka K. Bizheva

Published Jan 1, 2007• 0 citations
Publisher

Abstract

Even-order dispersion cancellation—an effect previously identified with entanglement—is demonstrated using a spectrally-resolved white-light Mach-Zehnder interferometer. This simplifies an important interferometric measurement technique and clarifies the role of entanglement in quantum metrology.
DOI
10.1364/cqo.2007.csua39

Related papers

Even- and odd-order dispersion cancellation effects in a two-photon interferometer

Jing Qiu, Jian-Song Pan, Guo‐Yong Xiang +3 more

Dispersion cancellation effects have attracted much attention in both classical and quantum worlds. In this paper, we show that by implementing a delicate design in a Mach–Zehnder (MZ) interferometer, we can observe the cancellation of even- and odd-order dispersion by twisting the polarizers placed in front of two single-photon detectors. This polarization post-selection scheme demonstrates that the classical and quantum interferogram can be obtained in different cases in a single MZ interferometer.

Journal of the Optical Society of America B•Apr 24, 2015•1 citation

Classical dispersion-cancellation interferometry

Kevin J. Resch, P. Puvanathasan, Jeff S. Lundeen +2 more

Even-order dispersion cancellation, an effect previously identified with frequency-entangled photons, is demonstrated experimentally for the first time with a linear, classical interferometer. A combination of a broad bandwidth laser and a high resolution spectrometer was used to measure the intensity correlations between anti-correlated optical frequencies. Only 14% broadening of the correlation signal is observed when significant material dispersion, enough to broaden the regular interferogram by 4250%, is introduced into one arm of the interferometer.

arXiv:0704.3938•Optics Express•Jan 1, 2007•58 citations

Even-order dispersion-cancellation in low coherence interferometry

Kostadinka K. Bizheva, Prabakar Puvanathasan, Jeff S. Lundeen +2 more

Even-order dispersion cancellation, an effect previously identified with frequency-entanglement, is demonstrated using a broadband low coherence interferometer and a spectrometer. This interferometer signal broadens by 14% when enough dispersion is introduced to broaden a standard interferogram by 4250%.

Frontiers in Optics•Jan 1, 2007•0 citations

Dispersion cancellation in a triple Laue interferometer

Hartmut Lemmel

The concept of dispersion cancellation has been established in light optics to improve the resolution of interferometric measurements on dispersive media. Odd order dispersion cancellation allows to measure phase shifts without defocusing the interferometer due to wave packet displacements, while even order dispersion cancellation allows to measure time lags without losing resolution due to wave packet spreading. We report that either type of dispersion cancellation can be realized very easily in a triple Laue interferometer. Such interferometers are Mach–Zehnder interferometers based on Bragg diffraction, and are commonly used for neutrons and x-rays. Although the first x-ray interferometer was built nearly five decades ago, the feature of dispersion cancellation hasnʼt been recognized so far because the concept was hardly known in the neutron and x-ray community. However, it explains right away the surprising decoupling of phase shift and spatial displacement that we have discovered recently in neutron interferometry (Lemmel and Wagh 2010 Phys. Rev. A 82 033626). Furthermore, this article might inspire the light optics community to consider whether a triple Laue interferometer for laser light would be useful and feasible. We explain how dispersion cancellation works in neutron interferometry, and we describe the setup rigorously by solving the Schrodinger equation and by calculating the path integral. We point out, that the latter has to be evaluated with special care since in our setup the beam trajectory moves with respect to the crystal lattice of the interferometer.

Journal of Optics•Sep 4, 2014•1 citation

A Franson Interferometer for Broadband Frequency-Entangled Photon Pairs

Luis Matheis, Sebastian Gstir, Gregor Weihs +1 more

In a Franson interferometer two-photon interference fringes occur despite the photons never encountering each other [1]. This phenomenon is a fundamental demonstration of the nonlocal nature of quantum mechanics. It serves also as a direct proof of frequency-time-entanglement. Furthermore, it can benefit not only from local, but also nonlocal dispersion cancellation techniques [2], which is a very useful property when working with spectrally broad photon pairs. More specifically, one has to distinguish between dispersion occuring before the individual Mach-Zehnder interferometers (MZIs), which constitute the Franson interferometer, and within them. Analysis of influences up to second order has shown that no loss of contrast can be expected from dispersion before the Franson interferometer. Differential second-order dispersion inside the interferometer, however, can cause a reduction of contrast in the interferogram [3].

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 26, 2023•0 citations

Odd- and Even-Order Dispersion Cancellation in Quantum Interferometry

Olga V. Minaeva, Cristian Bonato, Bahaa E. A. Saleh +2 more

We describe a novel effect involving odd-order dispersion cancellation. We demonstrate that odd- and even-order dispersion cancellation may be obtained in different regions of a single quantum interferogram using frequency-anticorrelated entangled photons and a new type of quantum interferometer. This offers new opportunities for quantum communication and metrology in dispersive media.

arXiv:0810.2621•Physical Review Letters•Mar 12, 2009•39 citations
Dispersion cancellation effects have attracted much attention in both classical and quantum worlds. In this paper, we show that by implementing a delicate design in a Mach–Zehnder (MZ) interferometer, we can observe the cancellation of even- and odd-order dispersion by twisting the polarizers placed in front of two single-photon detectors. This polarization post-selection scheme demonstrates that the classical and quantum interferogram can be obtained in different cases in a single MZ interferometer.
Even-order dispersion cancellation, an effect previously identified with frequency-entangled photons, is demonstrated experimentally for the first time with a linear, classical interferometer. A combination of a broad bandwidth laser and a high resolution spectrometer was used to measure the intensity correlations between anti-correlated optical frequencies. Only 14% broadening of the correlation signal is observed when significant material dispersion, enough to broaden the regular interferogram by 4250%, is introduced into one arm of the interferometer.
The concept of dispersion cancellation has been established in light optics to improve the resolution of interferometric measurements on dispersive media. Odd order dispersion cancellation allows to measure phase shifts without defocusing the interferometer due to wave packet displacements, while even order dispersion cancellation allows to measure time lags without losing resolution due to wave packet spreading. We report that either type of dispersion cancellation can be realized very easily in a triple Laue interferometer. Such interferometers are Mach–Zehnder interferometers based on Bragg diffraction, and are commonly used for neutrons and x-rays. Although the first x-ray interferometer was built nearly five decades ago, the feature of dispersion cancellation hasnʼt been recognized so far because the concept was hardly known in the neutron and x-ray community. However, it explains right away the surprising decoupling of phase shift and spatial displacement that we have discovered recently in neutron interferometry (Lemmel and Wagh 2010 Phys. Rev. A 82 033626). Furthermore, this article might inspire the light optics community to consider whether a triple Laue interferometer for laser light would be useful and feasible. We explain how dispersion cancellation works in neutron interferometry, and we describe the setup rigorously by solving the Schrodinger equation and by calculating the path integral. We point out, that the latter has to be evaluated with special care since in our setup the beam trajectory moves with respect to the crystal lattice of the interferometer.
In a Franson interferometer two-photon interference fringes occur despite the photons never encountering each other [1]. This phenomenon is a fundamental demonstration of the nonlocal nature of quantum mechanics. It serves also as a direct proof of frequency-time-entanglement. Furthermore, it can benefit not only from local, but also nonlocal dispersion cancellation techniques [2], which is a very useful property when working with spectrally broad photon pairs. More specifically, one has to distinguish between dispersion occuring before the individual Mach-Zehnder interferometers (MZIs), which constitute the Franson interferometer, and within them. Analysis of influences up to second order has shown that no loss of contrast can be expected from dispersion before the Franson interferometer. Differential second-order dispersion inside the interferometer, however, can cause a reduction of contrast in the interferogram [3].