A dynamic correspondence is set up between the density matrix of the electromagnetic field and an associated classical function. Means of one and two time quantum operators are shown to be obtainable from the corresponding averages of the associated classical random problem. When all atomic response rates are fast compared to photon rates, the equation of motion is obtained for the field density matrix. The associated classical problem is shown to obey a Fokker-Planck equation. Over a broad region that includes the threshold region, the Fokker-Planck equation is reduced to that for the rotating-wave van der Pol oscillator for which exact numerical solutions have been previously obtained by Hempstead and Lax.
A fully quantum-mechanical treatment is given of field and population fluctuations in a homogeneously broadened laser. The field and population reservoirs have been replaced by dissipation coefficients (or transition probabilities) and noncommuting noise sources. The atomic polarization variables are adiabatically eliminated. The mean motion of an arbitrary operator function $M(b, {b}^{\ifmmode\dagger\else\textdagger\fi{}}, {N}_{1}, {N}_{2})$ of the field variables
b, ${b}^{\ifmmode\dagger\else\textdagger\fi{}}$ and the population variables
N1 and
N2 is calculated. The equation of motion for the density matrix $\ensuremath{\rho}(b, {b}^{\ifmmode\dagger\else\textdagger\fi{}}, {N}_{1}, {N}_{2}, t)$ is deduced, as well as the Fokker-Planck equation for the associated classical distribution function $P(\ensuremath{\beta}, {\ensuremath{\beta}}^{*}, {N}_{1}, {N}_{2}, t)$. The diffusion coefficients in the latter equation demonstrate the shot-noise origin of the fluctuations. The Fokker-Planck equation for
P is replaced by Langevin equations for $\ensuremath{\beta}$, ${\ensuremath{\beta}}^{*}$,
N1, and
N2 to facilitate adiabatic elimination of the population variables (when valid). The resulting Langevin equations for $\ensuremath{\beta}$, ${\ensuremath{\beta}}^{*}$ are converted to a Fokker-Planck equation for $P(\ensuremath{\beta}, {\ensuremath{\beta}}^{*}, t)$, to an operator equation for $\ensuremath{\rho}(b, {b}^{\ifmmode\dagger\else\textdagger\fi{}}, t)$, and to an equation for ${\ensuremath{\rho}}_{\mathrm{mn}}$, the field density matrix in the photon-number representation. The transformation $\ensuremath{\beta}={I}^{\frac{1}{2}}{e}^{\ensuremath{-}i\ensuremath{\phi}}$ to an ($I, \ensuremath{\phi}$) representation leads (a) to the steady-state solution
P(I) valid at all operating levels, and (b) to the phase linewidth. The transformation to new variables
N=21(m+n), $k=m\ensuremath{-}n$, permits the equation for ${\ensuremath{\rho}}_{\mathrm{mn}}$ to be replaced by a Fokker-Planck equation for $\ensuremath{\rho}(N, k, t)$. The latter permits a verification of the previously obtained phase linewidth and a solution for the steady-state $\ensuremath{\rho}(N)$.
A generalized Fokker-Planck equation is derived for a system undergoing optical bistability when the dominant source of fluctuations is due to fluctuations in the incident field rather than spontaneous emission. The fluctuations are treated as a time-dependent Gaussian process whose properties are determined by the individual laser's characteristics. Both amplitude and phase fluctuations are included on the incident laser field. The effect of fluctuations of the incident laser on optical bistability are different for amplitude and phase fluctuations and are different for absorptive and dispersive optical bistability. The combination of incident laser phase fluctuations and dispersive optical bistability leads to large amplitude fluctuations near the turning points of the optical bistability curve and causes the system to make a transition from one branch of the optical bistability curve to the other before reaching the mean-field turning points. We take the high-
Q cavity limit of our generalized Fokker-Planck equation, solve the linearized equations, and provide criteria for the magnitude of fluctuations in optical bistability in terms of laser and cavity parameters. The magnitude of incident laser fluctuations are typically orders of magnitude larger than fluctuations due to spontaneous emission and are therefore important for practical applications of optical bistability devices.