Journal of Modern Optics

Squeezed States for Interferometric Gravitational-wave Detectors

Julio R. Gea-Banacloche, Gerd Leuchs

Published Jun 1, 1987• 97 citations
Publisher

Abstract

The possibility of using squeezed states for improving the shot-noise limit of the strain sensitivity of Michelson interferometers is discussed. We find that the spectrum of squeezing required depends on the method of stabilization used in the experiment. Details are given for the widely used phase-modulation technique (which also allows for recycling of the field), where we find an important application for broadband (‘two-mode’) squeezing.

DOI
10.1080/09500348714550751

Related papers

Analysis of a sub-shot-noise power recycled Michelson interferometer

Kirk McKenzie, B. C. Buchler, D. A. Shaddock +2 more

The sensitivity of interferometric gravitational wave detectors is ultimately limited by the 'quantum noise' of light. In this paper we compare results from a bench-top experiment and a theoretical model which show how squeezed states of light may be used to modify the quantum noise behaviour of a power recycled Michelson interferometer. We develop a simple theoretical model of the experiment and find close agreement of theoretical and experimental results. We measure quantum noise suppression of 2.3 dB and demonstrate the lock stability of the experiment for long periods.

Classical and Quantum Gravity•Feb 12, 2004•8 citations

Application of squeezed-state light to high-precision interferometry

Carlton M. Caves

A potential application of squeezed-state light is to improve the sensitivity of high-precision interferometers whose performance is generally limited by photon shot noise or photon-counting statistics. Such interferometers include passive laser gyroscopes and the very sensitive interferometers being developed to detect cosmic gravitational waves. One usually operates a high-precision interferometer in a differential mode, so that noise from the (laser) light source is in principle irrelevant. Operation in a differential mode means that there is a second, normally unused input port. Vacuum noise entering this second port is responsible for the irreducible photon shot noise at the interferometer’s output. Injecting squeezed-state light into the normally unused input port can improve the sensitivity. I discuss the use of squeezed-state light in ring interferometers, delayline Michelson interferometers, and Fabry-Perot interferometers. Included in the discussion are real degrading effects, such as losses, inefficient photodetectors, and laser noise in the presence of nonideal fringe contrast. I explore the compatibility of the squeezed-state technique with other exotic techniques for improving sensitivity, such as Drever's idea for power recycling. Sensitivity estimates for various configurations and techniques are presented.

Annual Meeting Optical Society of America•Jan 1, 1986•1 citation

Generation and detection of low-frequency squeezing for gravitational-wave detection

Michael Stefszky

Gravitational-wave astronomy promises a radically new method of investigating the universe, one that does not detect elementary particles, but rather ripples in space-time itself. One might expect that with this radically new method, our understanding of the universe will make an equally giant leap. One of the most promising methods for the eventual detection of gravitational-waves is that of interferometric gravitational-wave detection. The sensitivity of these devices is nothing short of amazing, and their sensitivity continues to improve. The next generation of detectors are expected reach a point where increasing the laser power, previously used to increase the sensitivity, is no longer expected to provide any benefit. One of the most promising options for further increasing the sensitivity, through reduction of the quantum noise, is via the application of "squeezed states of light". Squeezed states of light are light fields for which the noise of some observable has been reduced below the quantum noise limit. These states have been shown for many years to offer increased sensitivity in interferometers and recently in interferometric gravitational-wave detectors. One of the most challenging tasks to make suitable squeezed light sources for these detectors is to produce low-frequency squeezing, corresponding to the detection band of these interferometers. This thesis details the doubly resonant travelling wave bow-tie squeezer as a source of squeezing for interferometric gravitational-wave detection. This squeezer achieves record results of squeezing in the gravitational-wave detection band. For the first time, 10 dB of shot noise suppression at 10Hz is directly observed and above 200Hz, 11.6 dB is observed. The work presented in this thesis provides evidence that further substantiates previous progress indicating that squeezed states of light are now ready for full-time integration into interferometric gravitational-wave detectors. The new cavity design, described in detail throughout this thesis, is shown to outperform previous designs and provide benefits when integrating squeezing into these detectors, in particular, isolation to backscattered light from the interferometer. The noise sources that typically lead to degradation in squeezing measurements are investigated and discussed. Additionally, a modification to the standard locking technique used to control these vacuum squeezed states, coherent locking, is presented and discussed. The modified technique reduces the required number of locking loops and provides a larger beat note from which to derive an error signal for one of the remaining loops. A squeezer using these design philosophies is then constructed and used to inject squeezing into the LIGO gravitational-wave detector. Injection of the squeezed state provides enhancement of the sensitivity of the detector at frequencies around 200Hz and above. The sensitivity seen was equivalent to approximately 2 dB of shot noise reduction. The enhancement is limited by the loss within the interferometer. Injection of the squeezed state did not show any degradation in the sensitivity of the device below 200Hz, indicating for the first time that noise couplings between the interferometer and the squeezer could be sufficiently suppressed at these frequencies even for the most sensitive detectors.

•Jan 1, 2012•1 citation

Demonstration of a Squeezed-Light-Enhanced Power- and Signal-Recycled Michelson Interferometer

H. Vahlbruch, S. Chelkowski, Boris Hage +3 more

We report on the experimental combination of three advanced interferometer techniques for gravitational wave detection, namely, power recycling, detuned signal recycling, and squeezed field injection. For the first time, we experimentally prove the compatibility of especially the latter two. To achieve a broadband nonclassical sensitivity improvement, we applied a filter cavity for compensation of quadrature rotation. The signal-to-noise ratio was improved by up to 2.8 dB beyond the coherent state's shot noise. The complete setup was stably locked for arbitrary times and characterized by injected single-sideband modulation fields.

arXiv:0707.0166•Physical Review Letters•Nov 16, 2005•123 citations

Squeezed light for gravitational wave astronomy

H. Vahlbruch

During the recent years an international network of interferometric gravitational wave (GW) detectors has been commissioned and searches for various classes of GWsignals are ongoing.Although the observatories are beginning to reach astrophysically interesting sensitivity levels, extensive upgrades are aimed for the next decade bringing us into the era of gravitational wave astronomy.One approach to enhance the detector sensitivity is the injection of squeezed vacuum states of light replacing the vacuum fluctuations entering the detector through its antisymmetric port.In this thesis the unprecedented generation of squeezed vacuum states with a noise power 6.5 dB below vacuum noise within the entire detection bandwidth of ground-based GW-detectors (10 Hz -10 kHz) was experimentally demonstrated at a wavelength of 1064 nm.For the first time a coherent control scheme was employed for comprehensive phase control of the experimental setup.This scheme is directly applicable to future GW-detector topologies.In addition, parasitic interference induced by scattered light was found to be a dominant noise source degrading squeezed states in the audio band.The compatibility of squeezed field injection into a detuned operated dual-recycled Michelson interferometer was demonstrated in a table top experiment.A detected non-classical sensitivity improvement of up to 3.0 dB within the entire detection bandwidth (5 -15 MHz) was accomplished by optimal preparation of the injected squeezing by means of a detuned locked filter cavity.In a further experiment strongly squeezed vacuum states were generated in the MHz-regime.With a maximum measured quantum noise reduction of 11.5 dB below the shot noise limit a new benchmark was set.This was achieved by suppression of phase noise and a remarkable reduction of optical loss in the experimental setup.Based on the squeezed light sources developed in this thesis and the experimental results achieved, a conceptual design of a compact squeezed light source was devised, allowing for a high duty cycle sensitivity improvement of GW-detectors.

•Jan 1, 2008•12 citations

Squeezed light for the interferometric detection of high-frequency gravitational waves

Roman Schnabel, J. Harms, K. A. Strain +1 more

The quantum noise of the light field is a fundamental noise source in interferometric gravitational wave detectors. Injected squeezed light is capable of reducing the quantum noise contribution to the detector noise floor to values that surpass the so-called Standard-Quantum-Limit (SQL). In particular, squeezed light is useful for the detection of gravitational waves at high frequencies where interferometers are typically shot-noise limited, although the SQL might not be beaten in this case. We theoretically analyze the quantum noise of the signal-recycled laser interferometric gravitational-wave detector GEO600 with additional input and output optics, namely frequency-dependent squeezing of the vacuum state of light entering the dark port and frequency-dependent homodyne detection. We focus on the frequency range between 1 kHz and 10 kHz, where, although signal recycled, the detector is still shot-noise limited. It is found that the GEO600 detector with present design parameters will benefit from frequency dependent squeezed light. Assuming a squeezing strength of -6 dB in quantum noise variance, the interferometer will become thermal noise limited up to 4 kHz without further reduction of bandwidth. At higher frequencies the linear noise spectral density of GEO600 will still be dominated by shot-noise and improved by a factor of 10^{6dB/20dB}~2 according to the squeezing strength assumed. The interferometer might reach a strain sensitivity of 6x10^{-23} above 1 kHz (tunable) with a bandwidth of around 350 Hz. We propose a scheme to implement the desired frequency dependent squeezing by introducing an additional optical component to GEO600s signal-recycling cavity.

arXiv:gr-qc/0401119•Classical and Quantum Gravity•Feb 12, 2004•27 citations
The possibility of using squeezed states for improving the shot-noise limit of the strain sensitivity of Michelson interferometers is discussed. We find that the spectrum of squeezing required depends on the method of stabilization used in the experiment. Details are given for the widely used phase-modulation technique (which also allows for recycling of the field), where we find an important application for broadband (‘two-mode’) squeezing.
The sensitivity of interferometric gravitational wave detectors is ultimately limited by the 'quantum noise' of light. In this paper we compare results from a bench-top experiment and a theoretical model which show how squeezed states of light may be used to modify the quantum noise behaviour of a power recycled Michelson interferometer. We develop a simple theoretical model of the experiment and find close agreement of theoretical and experimental results. We measure quantum noise suppression of 2.3 dB and demonstrate the lock stability of the experiment for long periods.
A potential application of squeezed-state light is to improve the sensitivity of high-precision interferometers whose performance is generally limited by photon shot noise or photon-counting statistics. Such interferometers include passive laser gyroscopes and the very sensitive interferometers being developed to detect cosmic gravitational waves. One usually operates a high-precision interferometer in a differential mode, so that noise from the (laser) light source is in principle irrelevant. Operation in a differential mode means that there is a second, normally unused input port. Vacuum noise entering this second port is responsible for the irreducible photon shot noise at the interferometer’s output. Injecting squeezed-state light into the normally unused input port can improve the sensitivity. I discuss the use of squeezed-state light in ring interferometers, delayline Michelson interferometers, and Fabry-Perot interferometers. Included in the discussion are real degrading effects, such as losses, inefficient photodetectors, and laser noise in the presence of nonideal fringe contrast. I explore the compatibility of the squeezed-state technique with other exotic techniques for improving sensitivity, such as Drever's idea for power recycling. Sensitivity estimates for various configurations and techniques are presented.
Gravitational-wave astronomy promises a radically new method of investigating the universe, one that does not detect elementary particles, but rather ripples in space-time itself. One might expect that with this radically new method, our understanding of the universe will make an equally giant leap. One of the most promising methods for the eventual detection of gravitational-waves is that of interferometric gravitational-wave detection. The sensitivity of these devices is nothing short of amazing, and their sensitivity continues to improve. The next generation of detectors are expected reach a point where increasing the laser power, previously used to increase the sensitivity, is no longer expected to provide any benefit. One of the most promising options for further increasing the sensitivity, through reduction of the quantum noise, is via the application of "squeezed states of light". Squeezed states of light are light fields for which the noise of some observable has been reduced below the quantum noise limit. These states have been shown for many years to offer increased sensitivity in interferometers and recently in interferometric gravitational-wave detectors. One of the most challenging tasks to make suitable squeezed light sources for these detectors is to produce low-frequency squeezing, corresponding to the detection band of these interferometers. This thesis details the doubly resonant travelling wave bow-tie squeezer as a source of squeezing for interferometric gravitational-wave detection. This squeezer achieves record results of squeezing in the gravitational-wave detection band. For the first time, 10 dB of shot noise suppression at 10Hz is directly observed and above 200Hz, 11.6 dB is observed. The work presented in this thesis provides evidence that further substantiates previous progress indicating that squeezed states of light are now ready for full-time integration into interferometric gravitational-wave detectors. The new cavity design, described in detail throughout this thesis, is shown to outperform previous designs and provide benefits when integrating squeezing into these detectors, in particular, isolation to backscattered light from the interferometer. The noise sources that typically lead to degradation in squeezing measurements are investigated and discussed. Additionally, a modification to the standard locking technique used to control these vacuum squeezed states, coherent locking, is presented and discussed. The modified technique reduces the required number of locking loops and provides a larger beat note from which to derive an error signal for one of the remaining loops. A squeezer using these design philosophies is then constructed and used to inject squeezing into the LIGO gravitational-wave detector. Injection of the squeezed state provides enhancement of the sensitivity of the detector at frequencies around 200Hz and above. The sensitivity seen was equivalent to approximately 2 dB of shot noise reduction. The enhancement is limited by the loss within the interferometer. Injection of the squeezed state did not show any degradation in the sensitivity of the device below 200Hz, indicating for the first time that noise couplings between the interferometer and the squeezer could be sufficiently suppressed at these frequencies even for the most sensitive detectors.
We report on the experimental combination of three advanced interferometer techniques for gravitational wave detection, namely, power recycling, detuned signal recycling, and squeezed field injection. For the first time, we experimentally prove the compatibility of especially the latter two. To achieve a broadband nonclassical sensitivity improvement, we applied a filter cavity for compensation of quadrature rotation. The signal-to-noise ratio was improved by up to 2.8 dB beyond the coherent state's shot noise. The complete setup was stably locked for arbitrary times and characterized by injected single-sideband modulation fields.
During the recent years an international network of interferometric gravitational wave (GW) detectors has been commissioned and searches for various classes of GWsignals are ongoing.Although the observatories are beginning to reach astrophysically interesting sensitivity levels, extensive upgrades are aimed for the next decade bringing us into the era of gravitational wave astronomy.One approach to enhance the detector sensitivity is the injection of squeezed vacuum states of light replacing the vacuum fluctuations entering the detector through its antisymmetric port.In this thesis the unprecedented generation of squeezed vacuum states with a noise power 6.5 dB below vacuum noise within the entire detection bandwidth of ground-based GW-detectors (10 Hz -10 kHz) was experimentally demonstrated at a wavelength of 1064 nm.For the first time a coherent control scheme was employed for comprehensive phase control of the experimental setup.This scheme is directly applicable to future GW-detector topologies.In addition, parasitic interference induced by scattered light was found to be a dominant noise source degrading squeezed states in the audio band.The compatibility of squeezed field injection into a detuned operated dual-recycled Michelson interferometer was demonstrated in a table top experiment.A detected non-classical sensitivity improvement of up to 3.0 dB within the entire detection bandwidth (5 -15 MHz) was accomplished by optimal preparation of the injected squeezing by means of a detuned locked filter cavity.In a further experiment strongly squeezed vacuum states were generated in the MHz-regime.With a maximum measured quantum noise reduction of 11.5 dB below the shot noise limit a new benchmark was set.This was achieved by suppression of phase noise and a remarkable reduction of optical loss in the experimental setup.Based on the squeezed light sources developed in this thesis and the experimental results achieved, a conceptual design of a compact squeezed light source was devised, allowing for a high duty cycle sensitivity improvement of GW-detectors.
The quantum noise of the light field is a fundamental noise source in interferometric gravitational wave detectors. Injected squeezed light is capable of reducing the quantum noise contribution to the detector noise floor to values that surpass the so-called Standard-Quantum-Limit (SQL). In particular, squeezed light is useful for the detection of gravitational waves at high frequencies where interferometers are typically shot-noise limited, although the SQL might not be beaten in this case. We theoretically analyze the quantum noise of the signal-recycled laser interferometric gravitational-wave detector GEO600 with additional input and output optics, namely frequency-dependent squeezing of the vacuum state of light entering the dark port and frequency-dependent homodyne detection. We focus on the frequency range between 1 kHz and 10 kHz, where, although signal recycled, the detector is still shot-noise limited. It is found that the GEO600 detector with present design parameters will benefit from frequency dependent squeezed light. Assuming a squeezing strength of -6 dB in quantum noise variance, the interferometer will become thermal noise limited up to 4 kHz without further reduction of bandwidth. At higher frequencies the linear noise spectral density of GEO600 will still be dominated by shot-noise and improved by a factor of 10^{6dB/20dB}~2 according to the squeezing strength assumed. The interferometer might reach a strain sensitivity of 6x10^{-23} above 1 kHz (tunable) with a bandwidth of around 350 Hz. We propose a scheme to implement the desired frequency dependent squeezing by introducing an additional optical component to GEO600s signal-recycling cavity.