Japanese Journal of Applied Physics

Real-Time Measurement of the Population Densities in Gd Atomic Vapor Using Diode Laser Absorption Spectroscopy at 394.554 nm

Euo Chang Jung, Kwang-Hoon Ko, Taek-Soo Kim, Duck-Hee Kwon

Published Feb 10, 2004• 3 citations
Publisher

Abstract

The absorption spectra of two transitions originating from 0 and 999 cm -1 for atomic Gd were investigated at 394.554 nm. Newly measured transition probabilities are reported. Because of a narrow spectral difference of approximately 0.195 cm -1 between the two transitions, rapid sweeping of the diode laser wavelength made it possible to record both the absorption spectra simultaneously. The adopted technique enabled the real-time monitoring of the fraction of the Gd vapor at the ground energy level.

DOI
10.1143/jjap.43.822

Related papers

Fast online rubidium DPAL atomic concentration measurement by 420 nm probe laser

Hui-Zi Zhao, Hong-Yan Wang, Hao Tang +5 more

The alkali atom concentration plays an important role in the performance of a diode pumped alkali vapor laser (DPAL). At the rubidium DPAL operational region, the alkali concentration is as high as 1 0 13 − 1 0 14 c m − 3 , which is “optically thick,” or opaque, for the 780 nm or 795 nm doublet D lines when the traditional scanning absorption spectrum method is used for concentration measurement. To solve this problem, we propose the use of a probe laser of 420 nm, which corresponds to the 5 2 S 1 / 2 to 6 2 P 3 / 2 transition and has a lower absorption cross section compared to the D-line doublet. Due to the moderate absorption strength at a fixed 420 nm probe wavelength, we realized fast, online measurement of the Rb concentration in a real-world DPAL. By combining it with the quasi-two-level model, we further provided the population distribution in the lower three energy levels. This fast, online diagnostic method could be well applied in DPAL concentration measurement, and could show the dynamics of a laser’s performance.

Applied Optics•Oct 14, 2021•1 citation

Two-photon two-color diode laser spectroscopy of the Rb 5D5/2state

Timothy T. Grove, V. Sánchez-Villicaña, B C Duncan +2 more

We report on spectroscopic measurements of the Rb 5 D 5/2 state performed using two-photon excitation with a resonant intermediate state. With the two beams (5 S 1/2 → 5 P 3/2 at 780 nm and 5 P 3/2 → 5 D 5/2 at 776 nm) counterpropagating, the spectra are Doppler-free and the signals are very robust, even in a room temperature vapor. This is due to the near match of the transition wavelengths. The 5 D 5/2 hyperfine constants have been measured and compared to previous determinations. We have also performed the excitation in a sample of laser-cooled atoms and compare these results to those obtained at room temperature. The fact that the 5 P 3/2 → 5 D 5/2 transition is narrow, robust, diode-laser accessible, and relatively immune to AC-Stark shifts, may make it a promising candidate for a frequency reference at 776 nm.

Physica Scripta•Sep 1, 1995•74 citations

Rubidium Absorption Spectroscopy

Ignacio E. Olivares

In this chapter, we present a study of laser absorption in neutral rubidium vapor at a wavelength of 780 nm. The experiments were conducted using a tunable external cavity diode laser tuned to the https://www.w3.org/1998/Math/MathML" display="inline"> 85 Rb − D 2 transition line. We modeled the dependence of the laser transmission on the incident intensity using the optical Bloch equations described previously, comparing the theoretical results with the experimental data. Furthermore, the calculations were extended to the regime of saturated absorption spectroscopy, where the theoretical predictions were rigorously compared with the measured saturated absorption spectra.

CRC Press eBooks•Nov 6, 2026•0 citations

Measurement of Gd-atom metastable levels by laser-induced fluorescence spectroscopy

Jianan Y. Qu, Zhiyao Zhou, Zhu Lizhou +4 more

The atomic-beam velocity distribution of Gd atomic metastable levels, 215 cm −1 , 533 cm −1 were measured by means of the laser induced fluorescence method. Their lifetimes are deduced from the change of the velocity distributions at two different probe areas along the beam axis. The experimental results show that this is a very simple, sensitive and effective method to measure the lifetime of atomic metastable level

Acta Physica Sinica•Jan 1, 1992•0 citations

Measurement of Gd atom metastable levels by laser induced fluorescence spectroscopy

Lina Hu

The atomic beam velocity distribution of Gd atomic metastable levels, 215cm-1 533 cm-1 and 999 cm-1 were measured by means of laser induced fluorescence method. Their lifetimes are deduced from the change of the velocity distributions at two different probe areas along the beam axis. The experimental results show that this is a very simple, sensitive and effective method to measure the lifetime of atomic metastable level.

Acta Optica Sinica•Jan 1, 1991•0 citations

Frequency stabilization of diode laser on the wavelength of 5P3/2→5D5/2of rubidium transition

A.Yu. Kalatskiy, Anton E. Afanasiev, Pavel N. Melentiev +1 more

The method of frequency stabilization of diode laser on the wavelength of 5P3/2→5D5/2 of rubidium (776 nm) has been realized. The two-photon absorption spectroscopy of the rubidium vapors is underlie of the suggested scheme. The basic parameters such as the intensity of laser radiation and concentration of the vapors have been investigated. The frequency stability of radiation was about 1 MHz

EPJ Web of Conferences•Dec 13, 2016•0 citations
The absorption spectra of two transitions originating from 0 and 999 cm -1 for atomic Gd were investigated at 394.554 nm. Newly measured transition probabilities are reported. Because of a narrow spectral difference of approximately 0.195 cm -1 between the two transitions, rapid sweeping of the diode laser wavelength made it possible to record both the absorption spectra simultaneously. The adopted technique enabled the real-time monitoring of the fraction of the Gd vapor at the ground energy level.
The alkali atom concentration plays an important role in the performance of a diode pumped alkali vapor laser (DPAL). At the rubidium DPAL operational region, the alkali concentration is as high as 1 0 13 − 1 0 14 c m − 3 , which is “optically thick,” or opaque, for the 780 nm or 795 nm doublet D lines when the traditional scanning absorption spectrum method is used for concentration measurement. To solve this problem, we propose the use of a probe laser of 420 nm, which corresponds to the 5 2 S 1 / 2 to 6 2 P 3 / 2 transition and has a lower absorption cross section compared to the D-line doublet. Due to the moderate absorption strength at a fixed 420 nm probe wavelength, we realized fast, online measurement of the Rb concentration in a real-world DPAL. By combining it with the quasi-two-level model, we further provided the population distribution in the lower three energy levels. This fast, online diagnostic method could be well applied in DPAL concentration measurement, and could show the dynamics of a laser’s performance.
We report on spectroscopic measurements of the Rb 5 D 5/2 state performed using two-photon excitation with a resonant intermediate state. With the two beams (5 S 1/2 → 5 P 3/2 at 780 nm and 5 P 3/2 → 5 D 5/2 at 776 nm) counterpropagating, the spectra are Doppler-free and the signals are very robust, even in a room temperature vapor. This is due to the near match of the transition wavelengths. The 5 D 5/2 hyperfine constants have been measured and compared to previous determinations. We have also performed the excitation in a sample of laser-cooled atoms and compare these results to those obtained at room temperature. The fact that the 5 P 3/2 → 5 D 5/2 transition is narrow, robust, diode-laser accessible, and relatively immune to AC-Stark shifts, may make it a promising candidate for a frequency reference at 776 nm.
In this chapter, we present a study of laser absorption in neutral rubidium vapor at a wavelength of 780 nm. The experiments were conducted using a tunable external cavity diode laser tuned to the https://www.w3.org/1998/Math/MathML" display="inline"> 85 Rb − D 2 transition line. We modeled the dependence of the laser transmission on the incident intensity using the optical Bloch equations described previously, comparing the theoretical results with the experimental data. Furthermore, the calculations were extended to the regime of saturated absorption spectroscopy, where the theoretical predictions were rigorously compared with the measured saturated absorption spectra.