Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review Letters

Superconductors as Quantum Detectors for Microwave and Sub-Millimeter-Wave Radiation

E. Burstein, D. N. Langenberg, Barry N. Taylor

Published Feb 1, 1961• 50 citations
Publisher
DOI
10.1103/physrevlett.6.92

Related papers

Quantum Detection of Microwave- and Submillimeter-Wave Radiation Based on Electron Tunneling in Superconductors

E. Burstein, D. N. Langenberg, Barry N. Taylor

•Jan 1, 1961•0 citations

Millimeter wave radiation detectors of Josephson junctions.

Hiroshi Ohta

応用物理•Jan 1, 1982•1 citation

On-chip radiation detection from stacked Josephson flux-flow oscillators

S. V. Shitov, Alexey Vladimirovich Ustinov, N. N. Iosad +1 more

Radiation measurements with double-junction stacked Josephson flux-flow oscillator on-chip coupled to a superconductor–insulator–superconductor detector are reported. Impedance matching between the oscillator and the detector has been achieved using a broad band coupling circuit. Radiation power in the detector up to 10 nW has been measured in the frequency range between 170 and 410 GHz. Coherent radiation from two stacked junctions has been observed both at the fundamental Josephson frequency and at its second harmonic. The distribution of the radiation power between the first two harmonics allows us to distinguish between mutually coupled in-phase and out-of-phase flux-flow modes in the junctions. Coherent operation of stacked Josephson junction oscillators in the millimeter and sub-millimeter wave band is demonstrated.

Journal of Applied Physics•Dec 15, 1996•10 citations

Superconducting quantum-well device as a millimeter-wave detector

Hiroshi Ota, 太田 浩

•Jul 1, 1993•1 citation

Detection of mm and submm wave radiation from soliton and flux-flow modes in a long Josephson junction

Y.M. Zhang, Dag Winkler, T. Claeson

The authors report on the coupling of millimeter and submillimeter waves from a long (3- mu m*350- mu m) Josephson junction to a small (2- mu m*2- mu m) superconductor-insulator-superconductor (SIS) junction by using a center-fed interdigital capacitor. Coupled power at around 100 GHz and 261 GHz was observed. Experiments confirm that the critical current density j/sub c/ of a long junction determines the fluxon motion. Coupled irradiation (>3nW) at around 100 GHz, which corresponds to resonant soliton oscillations in low j/sub c/ samples (250 A/cm/sup 2/ to 1000 A/cm/sup 2/), is detected by the SIS junction. The incident power to the SIS detector junction could be tuned with only little frequency pulling by adjusting the current bias of the oscillator. For j/sub c/>1000 A/cm/sup 2/, coupled radiation at around 100 GHz (about 3 nW) and 261 GHz (4.6 nW), from flux-flow oscillations, is also clearly seen. Flux-flow radiation at 350 GHz is also observed. It is concluded that a large j/sub c/ value is preferable for high-frequency flux-flow oscillators.>

IEEE Transactions on Applied Superconductivity•Mar 1, 1993•17 citations

Dynamic range of frequency-selective response of high-T/sub c/ Josephson detector to millimeter-wave radiation

V.V. Shirotov, Yu. Ya. Divin, Knut W. Urban

We have studied a voltage dependence of the response /spl Delta/I(V) of high-T/sub c/ Josephson detector to millimeter-wave radiation as a function of power of incident radiation. YBa/sub 2/Cu/sub 3/O/sub 7-x/ grain-boundary junctions with the resistances R/sub n/=0.5-1.5 Ohm and the I/sub c/R/sub n/-product in the range 0.16-0.25 mV at 80 K have been fabricated for this study. Gunn oscillator with the frequency f=86 GHz and a set of calibrated attenuators with total attenuation of 80 dB have been used for the measurements. The dynamic range, i.e. the range of power of electromagnetic radiation at which the response of the detector is directly proportional to radiation power, was found to be around 40 dB above the noise-equivalent power for frequency-selective response at voltages V near hf/2e and >45 dB for the broadband response at low voltages.

IEEE Transactions on Applied Superconductivity•Mar 1, 2001•4 citations
Radiation measurements with double-junction stacked Josephson flux-flow oscillator on-chip coupled to a superconductor–insulator–superconductor detector are reported. Impedance matching between the oscillator and the detector has been achieved using a broad band coupling circuit. Radiation power in the detector up to 10 nW has been measured in the frequency range between 170 and 410 GHz. Coherent radiation from two stacked junctions has been observed both at the fundamental Josephson frequency and at its second harmonic. The distribution of the radiation power between the first two harmonics allows us to distinguish between mutually coupled in-phase and out-of-phase flux-flow modes in the junctions. Coherent operation of stacked Josephson junction oscillators in the millimeter and sub-millimeter wave band is demonstrated.
The authors report on the coupling of millimeter and submillimeter waves from a long (3- mu m*350- mu m) Josephson junction to a small (2- mu m*2- mu m) superconductor-insulator-superconductor (SIS) junction by using a center-fed interdigital capacitor. Coupled power at around 100 GHz and 261 GHz was observed. Experiments confirm that the critical current density j/sub c/ of a long junction determines the fluxon motion. Coupled irradiation (>3nW) at around 100 GHz, which corresponds to resonant soliton oscillations in low j/sub c/ samples (250 A/cm/sup 2/ to 1000 A/cm/sup 2/), is detected by the SIS junction. The incident power to the SIS detector junction could be tuned with only little frequency pulling by adjusting the current bias of the oscillator. For j/sub c/>1000 A/cm/sup 2/, coupled radiation at around 100 GHz (about 3 nW) and 261 GHz (4.6 nW), from flux-flow oscillations, is also clearly seen. Flux-flow radiation at 350 GHz is also observed. It is concluded that a large j/sub c/ value is preferable for high-frequency flux-flow oscillators.>
We have studied a voltage dependence of the response /spl Delta/I(V) of high-T/sub c/ Josephson detector to millimeter-wave radiation as a function of power of incident radiation. YBa/sub 2/Cu/sub 3/O/sub 7-x/ grain-boundary junctions with the resistances R/sub n/=0.5-1.5 Ohm and the I/sub c/R/sub n/-product in the range 0.16-0.25 mV at 80 K have been fabricated for this study. Gunn oscillator with the frequency f=86 GHz and a set of calibrated attenuators with total attenuation of 80 dB have been used for the measurements. The dynamic range, i.e. the range of power of electromagnetic radiation at which the response of the detector is directly proportional to radiation power, was found to be around 40 dB above the noise-equivalent power for frequency-selective response at voltages V near hf/2e and >45 dB for the broadband response at low voltages.