Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Nonlinear χ(2) Mach-Zehnder interferometer: Conditional preparation of maximal microscopic entanglement

Sergey A. Podoshvedov, Jaewan Kim

Published Mar 29, 2007• 5 citations
Publisher

Abstract

A nonlinear ${\ensuremath{\chi}}^{(2)}$ Mach-Zehnder interferometer is proposed as a simple device for conditional preparation of a two-photon maximally entangled state. Successful generation is unambiguously heralded by detection of a single photon in one of the routes of the nonlinear ${\ensuremath{\chi}}^{(2)}$ Mach-Zehnder interferometer. The mechanism of the conditional preparation is based on interference of the pumping modes. The scheme works without photon-number-resolving detection with a high fidelity.

DOI
10.1103/physreva.75.032346

Related papers

Modified nonclassical coherent state: Squeezing, antibunching, sub-Poissonian photon statistics, realization scheme with the χ(2)-nonlinearity, and generation of a macroscopic entangled state

Sergey A. Podoshvedov

The nonlinear χ (2) Mach-Zehnder interferometer is proposed as a device for conditional generation of a modified coherent nonclassical state. We show that the generated macroscopic state exhibits nonclassical effects, such as squeezing, photon antibunching, and sub-Poissonian statistics. The modified coherent state generates a macroscopic entangled state. The scheme works without the photon number resolving detection but requires high-efficiency photodetectors. We explain the mechanism of generation of the modified coherent non-classical state.

Journal of Experimental and Theoretical Physics•Apr 1, 2007•0 citations

Nonlinear interferometer as a resource for maximally entangled photonic states: Application to interferometry

Christopher C. Gerry, Adil Benmoussa, Richard A. Campos

Nonlinear interferometers are Mach-Zehnder interferometers with Kerr media in either one or both arms. We refer to these devices, respectively, as the asymmetric and symmetric nonlinear interferometers. In the asymmetric case, with one input mode in the vacuum, it is possible to generate maximally entangled photonic states or superpositions of such states. We consider the device as a resource of entangled states for applications to Heisenberg-limited interferometry. Interferometry with the maximally entangled states cannot be performed by simply subtracting the output photocounts as in standard interferometry. Instead, one must perform parity measurements on only one of the output beams. We show that the symmetric nonlinear interferometer, with one input mode in the vacuum, may be used to perform such parity measurements. The same device is shown to produce, with an input coherent state and upon projective measurements, even or odd coherent states, examples of the Schr\"odinger-cat states.

Physical Review A•Jul 11, 2002•102 citations

Testing quantum mechanics against macroscopic realism using the output of χ(2) nonlinearity

Sergey A. Podoshvedov, Jaewan Kim

We suggest an all-optical scheme to generate entangled superposition of a single photon with macroscopic entangled states for testing macroscopic realism. The scheme consists of source of single photons, a Mach-Zehnder interferometer in routes of which a system of coupled-down converters with type-I phase matching is inserted, and a beam splitter for the other auxiliary modes of the scheme. We use quantization of the pumping modes, depletion of the coherent states passing through the system, and interference effect in the pumping modes in the process of erasing which-path information of the single-photon on exit from the Mach-Zehnder interferometer. We show the macroscopic fields of the output superposition are distinguishable states. This scheme generates macroscopic entangled state that violates Bell's inequality. Moreover, the detailed analysis concerning change of amplitudes of entangled superposition by means of repeating this process many times is accomplished. We show our scheme works without photon number resolving detection and it is robust to detector inefficiency.

Physical Review A•Sep 15, 2006•15 citations

Generation of macroscopic entangled states by means of x(2) nonlinearity without photon number resolving detection

Sergey A. Podoshvedov

We generalize the scheme of conditional preparation of x (2) macroscopic entangled states [S.A. Podoshvedov, JETP 129 (2006)]. The studied system consists of a system of coupled down converters with type-I phase matching pumped simultaneously by powerful optical fields in coherent states with one auxiliary photon in the superposition state of two input modes and a projective measurement system. The projective measurement system involves two Hadamard gates introduced to generated output modes followed by photodetectors. Identification of macroscopic entangled states is produced by registration of one photon. No photon number resolving detection is required for the studied scheme.

Journal of Experimental and Theoretical Physics Letters•Jun 1, 2006•0 citations

Entangled photon generation using a fiber optic Mach-Zehnder interferometer incorporating the nonlinear effect in a fiber ring resonator

Preecha P. Yupapin, Suebtarkul Suchat

A new system for entangled photon-pair generation using an all-fiber optic scheme consists of a fiber optic Mach-Zehnder interferometer (MZI) incorporating a fiber optic ring resonator. The Kerr nonlinearity effect in the fiber ring resonator is exploited for the generation of two independent squeezed beams. The advantage of such a system is that it requires a simple arrangement without any optical pumping parts or bulky optical components. Polarized light pulse trains are launched randomly into a MZI, and one part of the light is delayed in the longer path. The output pulses from both arms of the MZI enter a fiber optic ring resonator. A polarization controller controls the polarization states of the light pulses while they circulate in the ring resonator. The superposition of the nonlinear light pulses in a fiber optic ring resonator randomly occur. These forms are seen on an avalanche photodetector. The results are in good agreement with previous work.

Journal of Nanophotonics•Jan 1, 2007•35 citations

Mach–Zehnder interferometer with squeezed and EPR entangled optical fields

Xudong Yu, Wei Li, Shi-Yao Zhu +1 more

We study a scheme for Mach–Zehnder (MZ) interferometer as a quantum linear device by injecting two-mode squeezed input states into two ports of interferometer. Two-mode squeezed states can be changed into two types of inputs for MZ interferometer: two squeezed states and Einstein–Podolsky–Rosen (EPR) entangled states. The interference patterns of the MZ interferometer vary periodically as the relative phase of the two arms of the interferometer is scanned, and are measured by the balanced homodyne detection system. Our experiments show that there are different interference patterns and periodicity of the output quantum states for two cases which depend on the relative phase of input optical fields. Since MZ interferometer can be used to realize some quantum operations, this work will have the important applications in quantum information and metrology.

Chinese Physics B•Feb 1, 2016•5 citations
A nonlinear \ensuremathχ(2){\ensuremath{\chi}}^{(2)}\ensuremathχ(2) Mach-Zehnder interferometer is proposed as a simple device for conditional preparation of a two-photon maximally entangled state. Successful generation is unambiguously heralded by detection of a single photon in one of the routes of the nonlinear \ensuremathχ(2){\ensuremath{\chi}}^{(2)}\ensuremathχ(2) Mach-Zehnder interferometer. The mechanism of the conditional preparation is based on interference of the pumping modes. The scheme works without photon-number-resolving detection with a high fidelity.
The nonlinear χ (2) Mach-Zehnder interferometer is proposed as a device for conditional generation of a modified coherent nonclassical state. We show that the generated macroscopic state exhibits nonclassical effects, such as squeezing, photon antibunching, and sub-Poissonian statistics. The modified coherent state generates a macroscopic entangled state. The scheme works without the photon number resolving detection but requires high-efficiency photodetectors. We explain the mechanism of generation of the modified coherent non-classical state.
Nonlinear interferometers are Mach-Zehnder interferometers with Kerr media in either one or both arms. We refer to these devices, respectively, as the asymmetric and symmetric nonlinear interferometers. In the asymmetric case, with one input mode in the vacuum, it is possible to generate maximally entangled photonic states or superpositions of such states. We consider the device as a resource of entangled states for applications to Heisenberg-limited interferometry. Interferometry with the maximally entangled states cannot be performed by simply subtracting the output photocounts as in standard interferometry. Instead, one must perform parity measurements on only one of the output beams. We show that the symmetric nonlinear interferometer, with one input mode in the vacuum, may be used to perform such parity measurements. The same device is shown to produce, with an input coherent state and upon projective measurements, even or odd coherent states, examples of the Schr\"odinger-cat states.
We suggest an all-optical scheme to generate entangled superposition of a single photon with macroscopic entangled states for testing macroscopic realism. The scheme consists of source of single photons, a Mach-Zehnder interferometer in routes of which a system of coupled-down converters with type-I phase matching is inserted, and a beam splitter for the other auxiliary modes of the scheme. We use quantization of the pumping modes, depletion of the coherent states passing through the system, and interference effect in the pumping modes in the process of erasing which-path information of the single-photon on exit from the Mach-Zehnder interferometer. We show the macroscopic fields of the output superposition are distinguishable states. This scheme generates macroscopic entangled state that violates Bell's inequality. Moreover, the detailed analysis concerning change of amplitudes of entangled superposition by means of repeating this process many times is accomplished. We show our scheme works without photon number resolving detection and it is robust to detector inefficiency.
We generalize the scheme of conditional preparation of x (2) macroscopic entangled states [S.A. Podoshvedov, JETP 129 (2006)]. The studied system consists of a system of coupled down converters with type-I phase matching pumped simultaneously by powerful optical fields in coherent states with one auxiliary photon in the superposition state of two input modes and a projective measurement system. The projective measurement system involves two Hadamard gates introduced to generated output modes followed by photodetectors. Identification of macroscopic entangled states is produced by registration of one photon. No photon number resolving detection is required for the studied scheme.
A new system for entangled photon-pair generation using an all-fiber optic scheme consists of a fiber optic Mach-Zehnder interferometer (MZI) incorporating a fiber optic ring resonator. The Kerr nonlinearity effect in the fiber ring resonator is exploited for the generation of two independent squeezed beams. The advantage of such a system is that it requires a simple arrangement without any optical pumping parts or bulky optical components. Polarized light pulse trains are launched randomly into a MZI, and one part of the light is delayed in the longer path. The output pulses from both arms of the MZI enter a fiber optic ring resonator. A polarization controller controls the polarization states of the light pulses while they circulate in the ring resonator. The superposition of the nonlinear light pulses in a fiber optic ring resonator randomly occur. These forms are seen on an avalanche photodetector. The results are in good agreement with previous work.
We study a scheme for Mach–Zehnder (MZ) interferometer as a quantum linear device by injecting two-mode squeezed input states into two ports of interferometer. Two-mode squeezed states can be changed into two types of inputs for MZ interferometer: two squeezed states and Einstein–Podolsky–Rosen (EPR) entangled states. The interference patterns of the MZ interferometer vary periodically as the relative phase of the two arms of the interferometer is scanned, and are measured by the balanced homodyne detection system. Our experiments show that there are different interference patterns and periodicity of the output quantum states for two cases which depend on the relative phase of input optical fields. Since MZ interferometer can be used to realize some quantum operations, this work will have the important applications in quantum information and metrology.