Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Microwave and Optical Technology Letters

Impact of kinetic inductance effect on high‐Tc

A.Z. Kain, J.M. Pond, Harold R. Fetterman, Charles M. Jackson

Published Oct 1, 1993• 9 citations
Publisher

Abstract

Abstract High‐Q transmission high‐Tcsuperconducting coplanar waveguide resonators have been employed to make accurate measurements of the temperature dependence of the penetration depth via the change in phase velocity. Resonators made from several different film thicknesses are well described using a zero temperature penetration depth and a T‐squared temperature dependence using a full‐wave spectral‐domain model of the coplanar waveguide transmission line. © 1993 John Wiley & Sons, Inc.

DOI
10.1002/mop.4650061310

Related papers

Kinetic Inductance of Superconducting Coplanar Waveguides

Koki Watanabe, Keiji Yoshida, Takeshi Aoki Kohjiro

An analytical expression for the kinetic inductance of the superconducting coplanar waveguide is given using the conformal mapping technique. This expression is shown to be in good agreement with experimental results obtained from the temperature dependence of the resonant frequency of the NbN coplanar waveguide resonators, especially in the case of a film thickness smaller than the magnetic penetration depth. It is also shown that the magnetic penetration depth of the superconducting thin films can be evaluated by this method.

Japanese Journal of Applied Physics•Oct 1, 1994•90 citations

Calculation of the characteristics of coplanar resonators for kinetic inductance detectors

Adrian Porch, Philip D. Mauskopf, Simon M. Doyle +1 more

Photon detectors based on the change of kinetic inductance of a thin superconducting film have a number of applications, particularly in astronomy, owing to their high sensitivity and ease of integration into large arrays. Here we discuss in detail the analysis of kinetic inductance detectors that use thin film microwave coplanar resonators. Photon absorption decreases the electron pair density, increasing the magnetic penetration depth /spl lambda/, which causes a decrease in the resonant frequency (or phase) of an irradiated resonator. To quantify this effect, we first compute the resonator current distribution, from which the /spl lambda/-dependent parameters (such as kinetic inductance) are calculated. Optimum responsivity for phase measurement is achieved by using the thinnest film with the narrowest center conductor width at the lowest possible temperature. However, the responsivity is compromised by extrinsic microwave losses, in particular due to residual surface resistance, which is likely to be significant in the thinnest films.

IEEE Transactions on Applied Superconductivity•Jun 1, 2005•19 citations

Measurements of phase shifts in YBCO transmission lines for evaluation of kinetic inductance change

Reiya Ishida, Tokio Goto, Hisashi Shimakage +1 more

Abstract We fabricated a coplanar waveguide (CPW) using high temperature superconductor YBa2Cu3O7-δ (YBCO) and evaluated its characteristics for the realization of a superconducting parametric amplifier. A YBCO thin film with a film thickness of 200 nm was formed by the PLD method using a YAG laser on a 10 × 10 mm MgO substrate. The YBCO thin films were processed into the CPW shape with a line width of 8 μm, a gap width of 8 μm and a line length of 5 mm by photolithography and sputter etching. Using a network analyzer, phase differences of microwave were measured at dc current bias from 0 mA to 14 mA. From the measurement results, it was found that the phase difference decreased with increasing temperature. In addition, it was found that the phase shifts greatly varied near the superconducting transition temperature at each current bias. We observed a maximum phase difference Δθ of -0.08 rad at a bias current of 14.0 mA, which is the closest to the transition temperature. A parametric gain was estimated to be 0.15 dB from the measured maximum phase difference.

Journal of Physics Conference Series•Sep 1, 2019•1 citation

Experimental demonstrations of high-Q superconducting coplanar waveguide resonators

HaiJie Li, YiWen Wang, LianFu Wei +6 more

We successfully designed and fabricated an absorption-type of superconducting coplanar waveguide (CPW) resonators. The resonators are made from a niobium film (about 160 nm thick) on a high-resistance Si substrate, and each resonator is fabricated as a meandered quarter-wavelength transmission line (one end is short to the ground and another end is capacitively coupled to a through feedline). With a vector network analyzer we measured the transmissions of the applied microwave through the resonators at ultra-low temperature. The obtained loaded quality factors are significantly high, i.e. up to ∼10 6 . When the temperature increases slowly from the base temperature (20 mK), the resonance frequencies of the resonators are blue shifted and the quality factors are lowered slightly. In principle, this type of device can integrate a series of CPW resonators with a common feedline, making it a promising candidate as the data bus for coupling distant solid-state qubits and the sensitive detector of single photons.

arXiv:1304.3254•Chinese Science Bulletin•Jul 1, 2013•29 citations

Ultra high quality factor resonators for kinetic inductance detectors

G. Hammer, S. Wünsch, K. Ilin +1 more

The sensitivity of a kinetic inductance detector is determined by the performance of the cavity circuit and therefore a high quality factor and low phase noise are required. We developed superconducting niobium coplanar waveguide resonators for kinetic inductance detectors at a resonance frequency of 6 GHz. The length of the resonators is adjusted to a quarter of a wavelength which corresponds to ≈ 5.3 mm in our geometry. Different layouts with coplanar waveguide transmission line topology for the resonator were designed and simulated. Some parameters of the device fabrication process were varied. The niobium thin films were deposited by magnetron sputtering on sapphire substrates kept at ambient temperature. The resonators were patterned by photolithography and reactive ion etching and measured at helium temperatures. Because of the quarter wave geometry with one shorted end the reflection parameter was measured. We have studied the influence of the coupling capacitances on quality factor. The optimization includes microwave simulations and implementation in different resonator structures. The measurements of optimized devices showed a very high quality factor above one million (10 6 ). The obtained results and perspective on further development of resonators will be discussed.

Journal of Physics Conference Series•Feb 1, 2008•12 citations

Fabrication and Characterization of Superconductive Coplanar Waveguide Resonators

Adem Ergül

The objective of this thesis is to evaluate a generic process for fabrication and characterization of the Superconductive coplanar waveguide (CPW) resonators. Superconductive CPW resonators with various lengths and shapes are designed to investigate their electrical and magnetic properties as well as resonance properties and sensitivities. In the first part of thesis, two different models are introduced in order to estimate the nonlinear kinetic inductance of a superconducting CPW resonator. The first model is based on Bean critical-state model and the second one is based on current dependence of London penetration depth. The existence of a shift in resonant frequency of Superconductive CPW resonator caused by a non-linear kinetic inductance is also shown experimentally. Simulations were carried out to estimate the nonlinear kinetic inductance due to the self- induced magnetic field penetration. The rest of the thesis is concerned with development of very smooth Aluminum (Al) thin films with RMS (Root Mean Square) roughness 1~nm and CAD (Computer Aid Design) of superconductive CPW resonators. Experimental investigation of a generic fabrication technique for superconductive CPW resonator is carried out. Many resonators are fabricated with different design parameters, such as centerline or gap width, film thickness and gap capacitors length. The fabrication process is described in detail. Electron Beam Lithography is used to fabricate Nb and Al CPW resonators which are coupled to outer conductors via gap capacitors. We have fabricated GHz frequency CPW resonators with quality factors, Q up 5X10^5.

•Jan 1, 2009•0 citations
Abstract High‐Q transmission high‐Tcsuperconducting coplanar waveguide resonators have been employed to make accurate measurements of the temperature dependence of the penetration depth via the change in phase velocity. Resonators made from several different film thicknesses are well described using a zero temperature penetration depth and a T‐squared temperature dependence using a full‐wave spectral‐domain model of the coplanar waveguide transmission line. © 1993 John Wiley & Sons, Inc.
An analytical expression for the kinetic inductance of the superconducting coplanar waveguide is given using the conformal mapping technique. This expression is shown to be in good agreement with experimental results obtained from the temperature dependence of the resonant frequency of the NbN coplanar waveguide resonators, especially in the case of a film thickness smaller than the magnetic penetration depth. It is also shown that the magnetic penetration depth of the superconducting thin films can be evaluated by this method.
Photon detectors based on the change of kinetic inductance of a thin superconducting film have a number of applications, particularly in astronomy, owing to their high sensitivity and ease of integration into large arrays. Here we discuss in detail the analysis of kinetic inductance detectors that use thin film microwave coplanar resonators. Photon absorption decreases the electron pair density, increasing the magnetic penetration depth /spl lambda/, which causes a decrease in the resonant frequency (or phase) of an irradiated resonator. To quantify this effect, we first compute the resonator current distribution, from which the /spl lambda/-dependent parameters (such as kinetic inductance) are calculated. Optimum responsivity for phase measurement is achieved by using the thinnest film with the narrowest center conductor width at the lowest possible temperature. However, the responsivity is compromised by extrinsic microwave losses, in particular due to residual surface resistance, which is likely to be significant in the thinnest films.
Abstract We fabricated a coplanar waveguide (CPW) using high temperature superconductor YBa2Cu3O7-δ (YBCO) and evaluated its characteristics for the realization of a superconducting parametric amplifier. A YBCO thin film with a film thickness of 200 nm was formed by the PLD method using a YAG laser on a 10 × 10 mm MgO substrate. The YBCO thin films were processed into the CPW shape with a line width of 8 μm, a gap width of 8 μm and a line length of 5 mm by photolithography and sputter etching. Using a network analyzer, phase differences of microwave were measured at dc current bias from 0 mA to 14 mA. From the measurement results, it was found that the phase difference decreased with increasing temperature. In addition, it was found that the phase shifts greatly varied near the superconducting transition temperature at each current bias. We observed a maximum phase difference Δθ of -0.08 rad at a bias current of 14.0 mA, which is the closest to the transition temperature. A parametric gain was estimated to be 0.15 dB from the measured maximum phase difference.
We successfully designed and fabricated an absorption-type of superconducting coplanar waveguide (CPW) resonators. The resonators are made from a niobium film (about 160 nm thick) on a high-resistance Si substrate, and each resonator is fabricated as a meandered quarter-wavelength transmission line (one end is short to the ground and another end is capacitively coupled to a through feedline). With a vector network analyzer we measured the transmissions of the applied microwave through the resonators at ultra-low temperature. The obtained loaded quality factors are significantly high, i.e. up to ∼10 6 . When the temperature increases slowly from the base temperature (20 mK), the resonance frequencies of the resonators are blue shifted and the quality factors are lowered slightly. In principle, this type of device can integrate a series of CPW resonators with a common feedline, making it a promising candidate as the data bus for coupling distant solid-state qubits and the sensitive detector of single photons.
The sensitivity of a kinetic inductance detector is determined by the performance of the cavity circuit and therefore a high quality factor and low phase noise are required. We developed superconducting niobium coplanar waveguide resonators for kinetic inductance detectors at a resonance frequency of 6 GHz. The length of the resonators is adjusted to a quarter of a wavelength which corresponds to ≈ 5.3 mm in our geometry. Different layouts with coplanar waveguide transmission line topology for the resonator were designed and simulated. Some parameters of the device fabrication process were varied. The niobium thin films were deposited by magnetron sputtering on sapphire substrates kept at ambient temperature. The resonators were patterned by photolithography and reactive ion etching and measured at helium temperatures. Because of the quarter wave geometry with one shorted end the reflection parameter was measured. We have studied the influence of the coupling capacitances on quality factor. The optimization includes microwave simulations and implementation in different resonator structures. The measurements of optimized devices showed a very high quality factor above one million (10 6 ). The obtained results and perspective on further development of resonators will be discussed.
The objective of this thesis is to evaluate a generic process for fabrication and characterization of the Superconductive coplanar waveguide (CPW) resonators. Superconductive CPW resonators with various lengths and shapes are designed to investigate their electrical and magnetic properties as well as resonance properties and sensitivities. In the first part of thesis, two different models are introduced in order to estimate the nonlinear kinetic inductance of a superconducting CPW resonator. The first model is based on Bean critical-state model and the second one is based on current dependence of London penetration depth. The existence of a shift in resonant frequency of Superconductive CPW resonator caused by a non-linear kinetic inductance is also shown experimentally. Simulations were carried out to estimate the nonlinear kinetic inductance due to the self- induced magnetic field penetration. The rest of the thesis is concerned with development of very smooth Aluminum (Al) thin films with RMS (Root Mean Square) roughness 1~nm and CAD (Computer Aid Design) of superconductive CPW resonators. Experimental investigation of a generic fabrication technique for superconductive CPW resonator is carried out. Many resonators are fabricated with different design parameters, such as centerline or gap width, film thickness and gap capacitors length. The fabrication process is described in detail. Electron Beam Lithography is used to fabricate Nb and Al CPW resonators which are coupled to outer conductors via gap capacitors. We have fabricated GHz frequency CPW resonators with quality factors, Q up 5X10^5.