Physical Review A

Test of the optical theory of Mössbauer quantum beats

E. H. du Marchie van Voorthuysen, G. L. Zhang, H. DE WAARD

Published Nov 1, 1984• 14 citations
Publisher

Abstract

Quantum-beat and sideband spectra of recoilless $\ensuremath{\gamma}$ radiation of $^{57}\mathrm{Fe}$ were measured as a function of frequency and the voltage on the quartz crystal on which a $^{57}\mathrm{Co}$ source was deposited. The sideband spectra were analyzed using a Rice distribution of the modulation index. The width of this distribution was shown to depend on the frequency; the narrowest distribution was found at 9.795 MHz. The results of the quantum-beat measurements are in agreement with the optical theory of Monahan and Perlow.

DOI
10.1103/physreva.30.2356

Related papers

QUANTUM BEATS OF RECOIL-FREE γ-RADIATION

G. J. Perlow, James E. Monahan, W. Potzel

The radiation from a Mössbauer source of 57Co in a copper matrix is frequency-modulated by vibrating the source with a quartz piezo-crystal driven by an oscillator. If the radiation passes through a resonant absorber (a "filter"), a time structure containing the oscillator frequency and its harmonics appears in the resulting counting rate. It may be seen by sorting the time of each count with respect to the cross-over time of a subharmonic of the oscillator. These quantum beats are caused by interferences between the frequency components of the photon amplitude, and vanish unless there is some alteration of relative phase or amplitude of the original radiation by the filter. The harmonic constitution of the beats is a sensitive function of the relative shift of source and filter and may be used as a sensitive probe of small shifts. This is demonstrated by measuring the temperature shift in 57Fe-Be. If a velocity spectrum is made with counts collected during only a part of the vibration cycle, prominent dispersion effects are seen, with counting rates higher than background in some portions of the spectrum. A classical optical theory of the phenomenon is presented in summary. It explains the beats, the dispersion effects, and the sensitivity of the harmonic ratios to relative shifts.

Le Journal de Physique Colloques•Jan 1, 1980•3 citations

Mössbauer Spectra and Quantum Beats of γ‐Rays Backscattered from a Resonance Absorber on an Oscillating Quartz

D. Kuhn, H. Jex

Abstract The elastic and inelastic backscattering from a resonance absorber bound to an oscillating quartz crystal is analyzed by means of 57Co Mössbauer γ‐radiation. The experiments are performed in the energy coordinate using the Doppler motion of the source and in the time domain with quantum beat techniques. Examples are presented of modulated backscattering spectra from the energy analysis and quantum beat signals from excitations with frequencies even below the radiation width.

physica status solidi (b)•Jun 1, 1993•0 citations

Theoretical description of quantum beats of recoil-free γ radiation

James E. Monahan, G. J. Perlow

A classical optical theory is given for the phenomenon of $\ensuremath{\gamma}$-ray quantum beats observed by Perlow in a study of the M\"ossbauer effect of a frequency-modulated source. The intensity $I({\ensuremath{\omega}}_{0}\ensuremath{-}{\ensuremath{\omega}}_{0}^{\ensuremath{'}},t)$ of the radiation from such a source transmitted through a resonant absorber is obtained as a function of ${\ensuremath{\omega}}_{0}\ensuremath{-}{\ensuremath{\omega}}_{0}^{\ensuremath{'}}$ and $t$, where ${\ensuremath{\omega}}_{0}^{\ensuremath{'}}$ is the frequency of an absorber resonance, ${\ensuremath{\omega}}_{0}$ is the central frequency of the frequency-modulated source, and $t$ is the laboratory time. An average is taken over the unobserved initial formation time of the excited nuclear state in the source. When viewed at fixed ${\ensuremath{\omega}}_{0}\ensuremath{-}{\ensuremath{\omega}}_{0}^{\ensuremath{'}}$, the calculated intensity displays beats in the time spectrum, and when viewed at fixed $t$, the intensity shows dispersion at appropriate values of ${\ensuremath{\omega}}_{0}\ensuremath{-}{\ensuremath{\omega}}_{0}^{\ensuremath{'}}$, responsible for the observed enhancement of intensity above background. The harmonic content of the quantum beats is calculated explicitly in the thin-absorber limit, and the observed linear variation about ${\ensuremath{\omega}}_{0}\ensuremath{-}{\ensuremath{\omega}}_{0}^{\ensuremath{'}}=0$ of the ratio of Fourier components $\frac{{D}_{1}}{{D}_{2}}$ is explained. The use of $\frac{{D}_{1}}{{D}_{2}}$ to measure small frequency shifts is analyzed by a statistical comparison with the method of switching between steepest points of the line, as used in gravitational-red-shift measurements. The variances are comparable. The effect on $I({\ensuremath{\omega}}_{0}\ensuremath{-}{\ensuremath{\omega}}_{0}^{\ensuremath{'}},t)$ of line broadening due to sample inhomogeneities is calculated for a Lorentz distribution of center frequencies in source and absorber, and a prescription is given for modifying the various terms in $I({\ensuremath{\omega}}_{0}\ensuremath{-}{\ensuremath{\omega}}_{0}^{\ensuremath{'}},t)$ accordingly. Finally, the effect of a distribution of phase and amplitude of the motion of the vibrating source is discussed.

Physical Review A•Oct 1, 1979•64 citations

PHASE COHERENCE OF FREQUENCY MODULATED MÖSSBAUER GAMMA RAYS

John D. Cashion, P.E. Clark

Frequency modulated sidebands in the spectrum of a Mössbauer source mounted on a piezoelectric crystal are known to be symmetrical. It is shown here that inclusion of a frequency modulated resonant filter into the system should result in unequal in tensities of corresponding positive and negative sidebands when the source and filter are modulated in antiphase. This asymmetry has been obtained previously but not commented upon and is more significant at low modulation indices.

Le Journal de Physique Colloques•Mar 1, 1979•3 citations

Interferometry in Energy Space using Mössbauer Radiation

S. L. Popov, G. V. Smirnov, Uwe van Bürck +1 more

Mössbauer radiation from a single-line source was converted into a set of harmonics by transmission through an ultrasound-vibrated SS foil. Energy and time analysis of the radiation revealed characteristic sidebands and quantum beats, respectively. When the radiation was further transmitted through a sample (a second SS foil) at rest, the original quantum beat pattern was shifted in time proportional to the sample thickness. This time beat shift originates from interference in energy space. It is analogous to the spatial fringe shifts in classical interferometry.

Europhysics Letters (EPL)•Nov 20, 1994•6 citations

High-resolution synchronized-quantum-beat spectroscopy using modulation sidebands: measurement of pressure shifts of the hyperfine splitting in sodium 3^2S_1/2

Yukio Fukuda, Kazuki KONDO, M. Tanigawa +1 more

Pressure shifts of the hyperfine splitting in Na 3(2)S((1/2)) that are due to buffer gases have been measured for the first time to our knowledge by all-optical means using the method of synchronized-quantum-beat spectroscopy reported previously [Y. Fukuda et al., Opt. Commun. 38, 357 (1981)]. The substate coherence is excited and detected with amplitude-modulated mode-locked laser pulses tuned to the D(1) line (pulse-repetition frequency, f(p); modulation frequency, f(m)), and the resonances observed at f(0) = nf(p) + ńf(m), (n and n' are integers) are used for the measurement. The pressure-shift coefficients obtained at 210 degrees C are 82, 61, -1, and -47 Hz/Torr for He, N(2), Ar, and Kr, respectively, within an accuracy of +/-3 Hz/Torr.

Optics Letters•Jun 1, 1983•7 citations
Quantum-beat and sideband spectra of recoilless \ensuremathγ\ensuremath{\gamma}\ensuremathγ radiation of 57Fe^{57}\mathrm{Fe}57Fe were measured as a function of frequency and the voltage on the quartz crystal on which a 57Co^{57}\mathrm{Co}57Co source was deposited. The sideband spectra were analyzed using a Rice distribution of the modulation index. The width of this distribution was shown to depend on the frequency; the narrowest distribution was found at 9.795 MHz. The results of the quantum-beat measurements are in agreement with the optical theory of Monahan and Perlow.
The radiation from a Mössbauer source of 57Co in a copper matrix is frequency-modulated by vibrating the source with a quartz piezo-crystal driven by an oscillator. If the radiation passes through a resonant absorber (a "filter"), a time structure containing the oscillator frequency and its harmonics appears in the resulting counting rate. It may be seen by sorting the time of each count with respect to the cross-over time of a subharmonic of the oscillator. These quantum beats are caused by interferences between the frequency components of the photon amplitude, and vanish unless there is some alteration of relative phase or amplitude of the original radiation by the filter. The harmonic constitution of the beats is a sensitive function of the relative shift of source and filter and may be used as a sensitive probe of small shifts. This is demonstrated by measuring the temperature shift in 57Fe-Be. If a velocity spectrum is made with counts collected during only a part of the vibration cycle, prominent dispersion effects are seen, with counting rates higher than background in some portions of the spectrum. A classical optical theory of the phenomenon is presented in summary. It explains the beats, the dispersion effects, and the sensitivity of the harmonic ratios to relative shifts.
A classical optical theory is given for the phenomenon of $\ensuremath{\gamma}$-ray quantum beats observed by Perlow in a study of the M\"ossbauer effect of a frequency-modulated source. The intensity $I({\ensuremath{\omega}}_{0}\ensuremath{-}{\ensuremath{\omega}}_{0}^{\ensuremath{'}},t)$ of the radiation from such a source transmitted through a resonant absorber is obtained as a function of ${\ensuremath{\omega}}_{0}\ensuremath{-}{\ensuremath{\omega}}_{0}^{\ensuremath{'}}$ and ttt, where ${\ensuremath{\omega}}_{0}^{\ensuremath{'}}$ is the frequency of an absorber resonance, ${\ensuremath{\omega}}_{0}$ is the central frequency of the frequency-modulated source, and ttt is the laboratory time. An average is taken over the unobserved initial formation time of the excited nuclear state in the source. When viewed at fixed ${\ensuremath{\omega}}_{0}\ensuremath{-}{\ensuremath{\omega}}_{0}^{\ensuremath{'}}$, the calculated intensity displays beats in the time spectrum, and when viewed at fixed ttt, the intensity shows dispersion at appropriate values of ${\ensuremath{\omega}}_{0}\ensuremath{-}{\ensuremath{\omega}}_{0}^{\ensuremath{'}}$, responsible for the observed enhancement of intensity above background. The harmonic content of the quantum beats is calculated explicitly in the thin-absorber limit, and the observed linear variation about ${\ensuremath{\omega}}_{0}\ensuremath{-}{\ensuremath{\omega}}_{0}^{\ensuremath{'}}=0$ of the ratio of Fourier components D1D2\frac{{D}_{1}}{{D}_{2}}D2​D1​​ is explained. The use of D1D2\frac{{D}_{1}}{{D}_{2}}D2​D1​​ to measure small frequency shifts is analyzed by a statistical comparison with the method of switching between steepest points of the line, as used in gravitational-red-shift measurements. The variances are comparable. The effect on $I({\ensuremath{\omega}}_{0}\ensuremath{-}{\ensuremath{\omega}}_{0}^{\ensuremath{'}},t)$ of line broadening due to sample inhomogeneities is calculated for a Lorentz distribution of center frequencies in source and absorber, and a prescription is given for modifying the various terms in $I({\ensuremath{\omega}}_{0}\ensuremath{-}{\ensuremath{\omega}}_{0}^{\ensuremath{'}},t)$ accordingly. Finally, the effect of a distribution of phase and amplitude of the motion of the vibrating source is discussed.
Mössbauer radiation from a single-line source was converted into a set of harmonics by transmission through an ultrasound-vibrated SS foil. Energy and time analysis of the radiation revealed characteristic sidebands and quantum beats, respectively. When the radiation was further transmitted through a sample (a second SS foil) at rest, the original quantum beat pattern was shifted in time proportional to the sample thickness. This time beat shift originates from interference in energy space. It is analogous to the spatial fringe shifts in classical interferometry.
Pressure shifts of the hyperfine splitting in Na 3(2)S((1/2)) that are due to buffer gases have been measured for the first time to our knowledge by all-optical means using the method of synchronized-quantum-beat spectroscopy reported previously [Y. Fukuda et al., Opt. Commun. 38, 357 (1981)]. The substate coherence is excited and detected with amplitude-modulated mode-locked laser pulses tuned to the D(1) line (pulse-repetition frequency, f(p); modulation frequency, f(m)), and the resonances observed at f(0) = nf(p) + ńf(m), (n and n' are integers) are used for the measurement. The pressure-shift coefficients obtained at 210 degrees C are 82, 61, -1, and -47 Hz/Torr for He, N(2), Ar, and Kr, respectively, within an accuracy of +/-3 Hz/Torr.