Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Study of the Dependence of Frequency Upon Microwave Power of Wall-Coated and Buffer-Gas-Filled Passive Rb87Frequency Standards

Allan S. Risley, Stephen Jarvis, Jaques Vanier

Published Jan 1, 1979• 0 citations
Publisher
DOI
10.1109/freq.1979.200358

Related papers

Possible Avenues of Improvement of the Short and Long Term Stability of Optically Pumped Passive Rubidium Frequency Standards

L.-G. Bernier, Anne Brisson, M. Têtu +2 more

The paper describes work done on the Passive Rubidium Frequency Standard in order to identify and possibly improve its frequency stability in the short and long term region. In relation to the short term region, experiments are described which permit the identification of the major sources of noise and measurements are reported. A theoretical model is developed and conclusions are drawn relative to the optimization of the various parameters. In relation to the long term region, earlier work has shown that the power shift created by inhomogeneous broadening in the presence of a buffer gas and light shift could be a cause of instabilities. To avoid that effect we have started experiments on a wall coated cell without buffer gas and we report results on the wall shift and its temperature dependence. Although that type of cell avoids the power shift, it is observed that the temperature dependence of the wall shift is relatively large. These results are discussed in terms of earlier data obtained on rubidium masers.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jan 1, 1980•2 citations

Saturation and Power Broadening of Microwave Resonance Lines

Paul I. Richards, Hartland S. Snyder

Physical Review•Feb 1, 1948•4 citations

The design of atomic frequency standards and their performance in specific applications

Samuel R. Stein

Progress in Quantum Electronics•Jan 1, 1984•4 citations

Analysis of Dicke Narrowing in Wall Coated and Buffer Gas Filled Cells with Application to Gas Cell Atomic Clocks

R. P. Frueholz, C. H. Volk

Spectral lineshape narrowing of atomic vapor emission in a bufferless, wall-coated absorption cell has been analyzed using the same formalism developed t3 describe sub-Doppler linewidths. Dicke-narrowing, in a buffered cell. Dramatic linewidth reductions in the bufferless cell, compared to the buffered cell, occur because of the high probability that Doppler shifts before and after a particular wall collision will cancel each other. The formalism described allows more physical insight than the classic onedimensional box model previously invoked to explain spectral narrowing in bufferless, wall coated cells. Additionally, this formalism reveals a correlation between post-collision velocities and intercollision times in the buffered cell resulting in modifications of the standard Dicke analysia of these cells. Finally, the computational power of the technique is demonstrated. The effects of varying cell size on Rb and CS hyperfine lineshapes and the results of the presence of an inhomogeneous magnetic field within the cell are analyzed.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jan 1, 1984•0 citations

Narrow 87Rb hyperfine-structure resonances in an evacuated wall-coated cell

H. G. Robinson, C. E. Johnson

Examination of 87Rb δF = 1, δ‖mF‖ = 1 hyperfine resonances in a 200-cm3 evacuated tetracontane wall-coated Pyrex cell which has been sealed since 1968 shows remarkable Dicke-narrowed sub-Doppler Lorentzian line shapes with less than 11 Hz full width. This linewidth is 70 times narrower than that in buffer gas filled cells used in commercial Rb atomic frequency standards. The phase shift per wall collision is 0.058 radians/collision as derived from an observed wall-induced hyperfine frequency shift of −52 Hz at a wall temperature of 26 °C.

Applied Physics Letters•May 1, 1982•84 citations

Certain frequency characteristics of a quantum frequency standard based on Rb37 vapors

M. P. Bespalova, N. N. Bogoslovskii, E. V. Kulagin +3 more

Radiophysics and Quantum Electronics•May 1, 1974•0 citations
The paper describes work done on the Passive Rubidium Frequency Standard in order to identify and possibly improve its frequency stability in the short and long term region. In relation to the short term region, experiments are described which permit the identification of the major sources of noise and measurements are reported. A theoretical model is developed and conclusions are drawn relative to the optimization of the various parameters. In relation to the long term region, earlier work has shown that the power shift created by inhomogeneous broadening in the presence of a buffer gas and light shift could be a cause of instabilities. To avoid that effect we have started experiments on a wall coated cell without buffer gas and we report results on the wall shift and its temperature dependence. Although that type of cell avoids the power shift, it is observed that the temperature dependence of the wall shift is relatively large. These results are discussed in terms of earlier data obtained on rubidium masers.
Spectral lineshape narrowing of atomic vapor emission in a bufferless, wall-coated absorption cell has been analyzed using the same formalism developed t3 describe sub-Doppler linewidths. Dicke-narrowing, in a buffered cell. Dramatic linewidth reductions in the bufferless cell, compared to the buffered cell, occur because of the high probability that Doppler shifts before and after a particular wall collision will cancel each other. The formalism described allows more physical insight than the classic onedimensional box model previously invoked to explain spectral narrowing in bufferless, wall coated cells. Additionally, this formalism reveals a correlation between post-collision velocities and intercollision times in the buffered cell resulting in modifications of the standard Dicke analysia of these cells. Finally, the computational power of the technique is demonstrated. The effects of varying cell size on Rb and CS hyperfine lineshapes and the results of the presence of an inhomogeneous magnetic field within the cell are analyzed.
Examination of 87Rb δF = 1, δ‖mF‖ = 1 hyperfine resonances in a 200-cm3 evacuated tetracontane wall-coated Pyrex cell which has been sealed since 1968 shows remarkable Dicke-narrowed sub-Doppler Lorentzian line shapes with less than 11 Hz full width. This linewidth is 70 times narrower than that in buffer gas filled cells used in commercial Rb atomic frequency standards. The phase shift per wall collision is 0.058 radians/collision as derived from an observed wall-induced hyperfine frequency shift of −52 Hz at a wall temperature of 26 °C.