Physical Review A

Generalized back-action evasion schemes for the detection of weak classical forces

Roberto Onofrio, Franco Bordoni

Published Mar 1, 1991• 7 citations
Publisher

Abstract

After a general review of the analysis already available for back-action evasion schemes a perturbative approach is introduced and applied to a simple case. As a generalization of the back-action evasion schemes the concept of optimal pumping spectrum is introduced: it works for a unified treatment of stroboscopic and continuous quantum nondemolition strategies. Generalized back-action evasion strategies are introduced and studied in simple applications: they open the possibility for developing high-sensitivity schemes for the measurements of small forces. In particular, estimates of the noise figure for generalized back-action evasion transducers are discussed in detail.

DOI
10.1103/physreva.43.2113

Related papers

On the measurement of a weak classical force coupled to a harmonic oscillator: experimental progress

Mark F. Bocko, Roberto Onofrio

Several high-precision physics experiments are approaching a level of sensitivity at which the intrinsic quantum nature of the experimental apparatus is the dominant source of fluctuations limiting the sensitivity of the measurements. This quantum limit is embodied by the Heisenberg uncertainty principle, which prohibits arbitrarily precise simultaneous measurements of two conjugate observables of a system but allows one-time measurements of a single observable with any precision. The dynamical evolution of a system immediately following a measurement limits the class of observables that may be measured repeatedly with arbitrary precision, with the influence of the measurement apparatus on the system being confined strictly to the conjugate observables. Observables having this feature, and the corresponding measurements performed on them have been named quantum nondemolition or back-action evasion observables. In a previous review (Caves et al., 1980, Rev. Mod. Phys. 52, 341) a quantum-mechanical analysis of quantum nondemolition measurements of a harmonic oscillator was presented. The present review summarizes the experimental progress on quantum nondemolition measurements and the classical models developed to describe and guide the development of practical implementations of quantum nondemolition measurements. The relationship between the classical and quantum theoretical models is also reviewed. The concept of quantum nondemolition and back-action evasion measurements originated in the context of measurements on a macroscopic mechanical harmonic oscillator, though these techniques may be useful in other experimental contexts as well, as is discussed in the last part of this review. [S0034-6861(96)00103-1]

Reviews of Modern Physics•Jul 1, 1996•196 citations

Generalized back-action evasion schemes for the detection of weak classical forces

Franco Bordoni, Roberto Onofrio

Unknown eBooks•Jun 1, 1990•0 citations

Multisqueezing of mechanical states and back-action evasion measurements

Franco Bordoni, Roberto Onofrio

A technique is proposed to improve the squeezing of the mechanical noise in a back-action evasion measurement. The scheme is based on the use of a parametric multipump system and, in the limit of many pump components, approaches a stroboscopic measurement. A simple model of the back-action evasion effect for this scheme is developed. Experimental evidence of a significant increase in the squeezing with respect to the two-pump scheme and in accordance with the model is reported.

Physical Review A•Jan 1, 1990•7 citations

Phase-Sensitive Detection and the Back-Action Evasion of Amplifier Force Noise (Measurement Theory, Transducers, Antenna, Gravitational Radiation, Accelerometer).

Gary W. Spetz

Limitations on the sensitivity for detecting a weak classical force acting on a harmonic oscillator are imposed by the quantum mechanical properties associated with a "standard" amplitude-and-phase measurement and, classically, by the back reaction noise associated with the finite noise temperature of the amplifier used to process the measurement. These are known as the "standard quantum limit" and the "standard amplifier limit", respectively. We present the theoretical motivation behind the quest to circumvent these limits, and examine a single-transducer back-action evading measurement scheme designed to perform a phase-sensitive coupling to the oscillator, with the concomitant circumvention of the standard amplifier limit via the "squeezing" of amplifier back reaction noise. The applicability of squeezing in the detection of gravitational radiation is explored via the dependence of detection sensitivity on the physical temperature and quality factor of the resonant-bar gravitational radiation antenna, on the noise temperature of the amplifier, and on the squeezing factor of the back-action evading measurement; the success of back-action evasion in improving upon the optimum amplitude-and-phase detection sensitivities depends critically upon these parameters. Using the LSU superconducting dual-cavity accelerometer as a test platform, we present direct evidence for the establishment of a phase-sensitive coupling to an oscillator, along with a variety of indirect corroborating evidence. This data indicates that our phase-sensitive measurement scheme is indeed more sensitive to one component of the oscillator than to the other component. We also present the first evidence for the existence of back-action evasion of amplifier back reaction noise. We show theoretical expectations and experimental results for the dependence of squeezing on: input signal phases, amplitudes, and frequencies; amplifier back reaction levels; background noise; mechanical oscillator frequency; and coherent carrier contribution at the cavity resonance frequency. Squeezing factors of up to fifteen were achieved by our back-action evading measurement scheme.

Civil War Book Review•Jan 1, 1985•0 citations

Surpassing the Amplifier Limit for Force Detection

Mark F. Bocko, Warren W. Johnson

A force-measuring system composed of a macroscopic harmonic oscillator, mechanical-electrical transducer, and linear amplifier is described and the sensitivity is calculated for a "back-action evasion" mode of operation. It is shown that it is possible to surpass the standard amplifier limit with this device, and the specific requirements to do so are given. These results may also apply to a quantum-limited amplifier and thus give the requirements to perform quantum-nondemolition measurements.

Physical Review Letters•May 17, 1982•38 citations

Back-Action Evasion as an Alternative to Impedance Matching

Bernard Yurke

Back-action evasion is a measurement technique originally devised to overcome certain limits imposed by quantum mechanics on the sensitivity of gravitational radiation detectors. The technique is, however, more generally applicable and can be used to improve the sensitivity of instrumentation with noise floors much greater than the quantum noise floor. The principle of back-action evasion is described here by means of a simple example. A comparison of back-action evasion with impedance matching is made to clarify when back-action evasion may be useful. Back-action evasion allows one to achieve a sensitivity comparable to that achieved by impedance matching.

Science•Apr 26, 1991•4 citations
After a general review of the analysis already available for back-action evasion schemes a perturbative approach is introduced and applied to a simple case. As a generalization of the back-action evasion schemes the concept of optimal pumping spectrum is introduced: it works for a unified treatment of stroboscopic and continuous quantum nondemolition strategies. Generalized back-action evasion strategies are introduced and studied in simple applications: they open the possibility for developing high-sensitivity schemes for the measurements of small forces. In particular, estimates of the noise figure for generalized back-action evasion transducers are discussed in detail.
Several high-precision physics experiments are approaching a level of sensitivity at which the intrinsic quantum nature of the experimental apparatus is the dominant source of fluctuations limiting the sensitivity of the measurements. This quantum limit is embodied by the Heisenberg uncertainty principle, which prohibits arbitrarily precise simultaneous measurements of two conjugate observables of a system but allows one-time measurements of a single observable with any precision. The dynamical evolution of a system immediately following a measurement limits the class of observables that may be measured repeatedly with arbitrary precision, with the influence of the measurement apparatus on the system being confined strictly to the conjugate observables. Observables having this feature, and the corresponding measurements performed on them have been named quantum nondemolition or back-action evasion observables. In a previous review (Caves et al., 1980, Rev. Mod. Phys. 52, 341) a quantum-mechanical analysis of quantum nondemolition measurements of a harmonic oscillator was presented. The present review summarizes the experimental progress on quantum nondemolition measurements and the classical models developed to describe and guide the development of practical implementations of quantum nondemolition measurements. The relationship between the classical and quantum theoretical models is also reviewed. The concept of quantum nondemolition and back-action evasion measurements originated in the context of measurements on a macroscopic mechanical harmonic oscillator, though these techniques may be useful in other experimental contexts as well, as is discussed in the last part of this review. [S0034-6861(96)00103-1]
Limitations on the sensitivity for detecting a weak classical force acting on a harmonic oscillator are imposed by the quantum mechanical properties associated with a "standard" amplitude-and-phase measurement and, classically, by the back reaction noise associated with the finite noise temperature of the amplifier used to process the measurement. These are known as the "standard quantum limit" and the "standard amplifier limit", respectively. We present the theoretical motivation behind the quest to circumvent these limits, and examine a single-transducer back-action evading measurement scheme designed to perform a phase-sensitive coupling to the oscillator, with the concomitant circumvention of the standard amplifier limit via the "squeezing" of amplifier back reaction noise. The applicability of squeezing in the detection of gravitational radiation is explored via the dependence of detection sensitivity on the physical temperature and quality factor of the resonant-bar gravitational radiation antenna, on the noise temperature of the amplifier, and on the squeezing factor of the back-action evading measurement; the success of back-action evasion in improving upon the optimum amplitude-and-phase detection sensitivities depends critically upon these parameters. Using the LSU superconducting dual-cavity accelerometer as a test platform, we present direct evidence for the establishment of a phase-sensitive coupling to an oscillator, along with a variety of indirect corroborating evidence. This data indicates that our phase-sensitive measurement scheme is indeed more sensitive to one component of the oscillator than to the other component. We also present the first evidence for the existence of back-action evasion of amplifier back reaction noise. We show theoretical expectations and experimental results for the dependence of squeezing on: input signal phases, amplitudes, and frequencies; amplifier back reaction levels; background noise; mechanical oscillator frequency; and coherent carrier contribution at the cavity resonance frequency. Squeezing factors of up to fifteen were achieved by our back-action evading measurement scheme.
A force-measuring system composed of a macroscopic harmonic oscillator, mechanical-electrical transducer, and linear amplifier is described and the sensitivity is calculated for a "back-action evasion" mode of operation. It is shown that it is possible to surpass the standard amplifier limit with this device, and the specific requirements to do so are given. These results may also apply to a quantum-limited amplifier and thus give the requirements to perform quantum-nondemolition measurements.
Back-action evasion is a measurement technique originally devised to overcome certain limits imposed by quantum mechanics on the sensitivity of gravitational radiation detectors. The technique is, however, more generally applicable and can be used to improve the sensitivity of instrumentation with noise floors much greater than the quantum noise floor. The principle of back-action evasion is described here by means of a simple example. A comparison of back-action evasion with impedance matching is made to clarify when back-action evasion may be useful. Back-action evasion allows one to achieve a sensitivity comparable to that achieved by impedance matching.