Physical Review A

One-atom maser: Phase-sensitive measurements

Berthold‐Georg Englert, Tserensodnom Gantsog, Axel Schenzle, Christian Wagner, HERBERT WALTHER

Published Jun 1, 1996• 30 citations
Publisher

Abstract

We reconsider a variant of the one-atom-maser setup in which the emerging atoms are probed for coherent superpositions of the two Rydberg states of the maser transition. The statistical properties of the corresponding detector clicks contain information about the temporal evolution of the phase of the quantized electromagnetic field inside the resonator. We derive analytical expressions for certain statistical quantities, such as the mean number of successive clicks of the same kind, or the atom-atom and the photon-photon correlation functions. The latter are closely related if the photon-number distribution in steady state is dominated by a single narrow peak. \textcopyright{} 1996 The American Physical Society.

DOI
10.1103/physreva.53.4386

Related papers

One-atom maser: Statistics of detector clicks

Hans‐Jürgen Briegel, Berthold‐Georg Englert, Nicoletta Sterpi +1 more

We present a general theory for the calculation of various characteristic properties of the beam of atoms emerging from a resonator in one-atom-maser experiments. The beam is described in terms of the statistics of the detector clicks. The evolution of the state of the maser photons between clicks is governed by a nonlinear master equation. The nonlinearity originates in the necessity to account for the atoms that escape detection. Despite the permanent reductions of the photon state, resulting from the detections, the steady state of the conventional linear master equation determines the statistics of the detector clicks. The whole process is ergodic, in the sense that a single run of the experiment contains all reproducible statistical data, provided the duration of the run is much longer than all relevant correlation times. The nonlinear master equation is used to calculate the distribution of waiting times between detector clicks. Other statistical properties of the clicks that are derived include correlation functions and variances of the counting statistics. The formalism is applied to standard one-atom-maser experiments and to parity measurements on both unpumped and pumped cavities. We find that, for the standard one-atom-maser operation, none of the said statistical properties is a simple immediate indicator for a sub-Poissonian variance of the photon number. For example, the detector clicks may be antibunched although the photon distribution has a super-Poissonian variance.

Physical Review A•Apr 1, 1994•83 citations

Single-atom experiments and the test of fundamental quantum physics

HERBERT WALTHER

The work on the one-atom maser is reviewed. The superconducting maser cavity made of niobium and cooled to 0.5 K to exclude thermal photons has a quality factor of 3 X 1010. Velocity-selected Rydberg atoms pump the maser. The field inside the cavity is investigated by probing the atoms leaving the cavity. The dynamics of the Rabi nutation were investigated. Furthermore, the statistics of the photons in the cavity were determined to be sub-Poissonian corresponding to photon-number fluctuations of 70% below the vacuum-state limit. The one-atom maser is the only maser system which leads to nonclassical radiation even when pumping processes with Poissonian statistics are used. Some applications of the one- atom maser to study the quantum measurement process also are discussed.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Oct 28, 1992•0 citations

Validity of the Semiclassical Approximation in Maser Theory

J.H. Shirley

A simple model of a maser or laser consisting of a single-mode field coupled to $N$ identical two-level atoms is considered. The semiclassical approximation is equivalent to neglecting the statistical correlations between the atoms and the field. The accuracy of this approximation is investigated by writing equations of motion for the correlations. To obtain a complete, self-consistent set of equations, it is necessary to include correlations of the field with itself (related to the coherence of the field) and correlations between different atoms. Relaxations and an energy source are introduced phenomenologically into the equations of motion. They are then solved for the case of steady-state oscillation. It is found that the correlations are smaller than the terms kept in the semiclassical theory by the order of 1 over the number of photons present in the field, larger if thermal photons abound, but smaller if the field relaxation is dominant. Expressions are also found for the amplitude and phase fluctuations of the field. The latter yield a linewidth for the maser oscillator in agreement with earlier calculations, but obtained by a different method.

Physical Review•May 10, 1969•19 citations

Experiments with the One-atom-maser

Linas Urbonas

There are only fistful of systems in physics that can be described by an exact theory from first principles and, at the same time, can be investigated under experimental conditions approaching the idealized theoretical ones. The one-atom-maser or micromaser provides such an example, making a detailed study of the fundamental properties of the atom-field interaction possible. The situation realized in a micromaser is very close to the ideal case of a single two-level atom interacting with a single quantized mode of a cavity field. In the micromaser the atoms have a dual purpose of both pumping the field and also probing it via measurements of the outgoing atoms. Any other means of measuring the field inside the resonator has the detrimental effect of lowering its Q-factor and thereby the photon storage time. The long photon storage time of the resonator allows for the decay of the field to be negligible during the passage of an atom and its interaction with the field. The behavior of atoms in a cavity is governed by the oscillatory exchange of energy between the atoms and the field, which is called Rabi oscillation. For cavity fields in the vacuum and few photon number states (Fock states), Rabi oscillations have been measured in the past. To prevent thermal effects from polluting the pure number states these experiments were performed at low temperatures (below 1 K). However, the observed resolution of the Rabi oscillations measurements was quite disappointing (only about 2% of the predicted theoretical value) and precluded more ambitious experiments like atom-atom correlations or time resolved investigations of the maser field dynamics. The observed contrast of Rabi oscillations can be considered as a figure of merit for the experimental resolution of quantum features of a maser field. Therefore, a high resolution in the measurements of Rabi oscillations is crucial. This thesis describes the methods and improvements applied to enhance the resolution of Rabi oscillations by a factor of 8. The following upgrades and developments proved to be crucial in this work: 1) The base temperature of the cryogenic system was lowered to 0.3 K, i.e. one third of the original value. At the same time, the time during which the system remains at the base temperature was improved by almost of an order of magnitude (to more than 12 h). 2) For the promotion of the atoms to the Rydberg regime new three-step diode laser setup was constructed. The excitation efficiency compared to the old dye laser was increased by two orders. Using top-of-fringe stabilization with new spectroscopic methods, specially designed error detection and feedback schemes as well as state-of-the-art PID regulators the continuous locking of lasers is about 8 h (compared to about 20 min with the old dye laser system). 3) The flexibility of using the three step excitation allows to excite different maser states and for the first time to investigate pure maser transition. 4) Various improvements on the atomic oven and the channeltron detection unit led to the reliable and stable production and detection of the atomic beam. Observed distribution of the atomic beam statistics reaches to within 6% the Poisson limit which is expected in the absence of experimental imperfections. 5) New developed techniques in magnetic field compensation allow to perform such measurements with two orders of magnitude better accuracy compared to the previous experiments. To demonstrate the new capabilities of the apparatus and to apply its improved resolution of quantum fields we performed a previously impossible in-depth analysis of mean photon number and the atomic inversion produced by a micromaser for various detunings between the cavity- and atomic resonance frequency.

•Jan 1, 2009•0 citations

Theory of detection in the micromaser

Rebecca R. McGowan, William C. Schieve

The field in the micromaser cavity, the atoms which both pump and probe the micromaser, and the detectors that determine the outgoing states of the atoms are treated as a single system in order to derive a nonlinear master equation for the field in the micromaser cavity which takes the effect of undetected atoms into account. Analytic solutions for this master equation are found for both phase-insensitive and phase-sensitive detection. These solutions can be used to explicitly show the back-action effects that measurement has on the spectrum of the micromaser. In addition, these solutions are used to find analytic expressions for the mean number of successive detector clicks of the same kind as well as atom-atom and photon-photon correlation functions. In this way, the analytic solutions are linked to experimentally accessible data.

Physical Review A•Jan 1, 1999•6 citations

The One-Atom Maser and the Generation of Nonclassical Light

Gerhard Rempe, Marlan O. Scully, HERBERT WALTHER

We review our recent work on the nonclassical radiation field of a one-atom maser. The maser cavity is cooled to 0.5 K to exclude thermal photons and has a quality factor of 3 × 10 10 . Velocity-selected Rydberg atoms pump the maser. The field inside the cavity is measured via the fluctuations in the number of atoms leaving the cavity in the lower maser level which are up to 40% below the Poisson level. This corresponds to photon-number fluctuations 70% below the vacuum-state limit. The one-atom maser is the only maser system which leads to nonclassical radiation even when pumping processes with Poissonian statistics are used. We analyse and propose new experiments based on the one-atom maser leading to new studies of the quantum measurement process.

Physica Scripta•Jan 1, 1991•25 citations
We reconsider a variant of the one-atom-maser setup in which the emerging atoms are probed for coherent superpositions of the two Rydberg states of the maser transition. The statistical properties of the corresponding detector clicks contain information about the temporal evolution of the phase of the quantized electromagnetic field inside the resonator. We derive analytical expressions for certain statistical quantities, such as the mean number of successive clicks of the same kind, or the atom-atom and the photon-photon correlation functions. The latter are closely related if the photon-number distribution in steady state is dominated by a single narrow peak. \textcopyright{} 1996 The American Physical Society.
We present a general theory for the calculation of various characteristic properties of the beam of atoms emerging from a resonator in one-atom-maser experiments. The beam is described in terms of the statistics of the detector clicks. The evolution of the state of the maser photons between clicks is governed by a nonlinear master equation. The nonlinearity originates in the necessity to account for the atoms that escape detection. Despite the permanent reductions of the photon state, resulting from the detections, the steady state of the conventional linear master equation determines the statistics of the detector clicks. The whole process is ergodic, in the sense that a single run of the experiment contains all reproducible statistical data, provided the duration of the run is much longer than all relevant correlation times. The nonlinear master equation is used to calculate the distribution of waiting times between detector clicks. Other statistical properties of the clicks that are derived include correlation functions and variances of the counting statistics. The formalism is applied to standard one-atom-maser experiments and to parity measurements on both unpumped and pumped cavities. We find that, for the standard one-atom-maser operation, none of the said statistical properties is a simple immediate indicator for a sub-Poissonian variance of the photon number. For example, the detector clicks may be antibunched although the photon distribution has a super-Poissonian variance.
The work on the one-atom maser is reviewed. The superconducting maser cavity made of niobium and cooled to 0.5 K to exclude thermal photons has a quality factor of 3 X 1010. Velocity-selected Rydberg atoms pump the maser. The field inside the cavity is investigated by probing the atoms leaving the cavity. The dynamics of the Rabi nutation were investigated. Furthermore, the statistics of the photons in the cavity were determined to be sub-Poissonian corresponding to photon-number fluctuations of 70% below the vacuum-state limit. The one-atom maser is the only maser system which leads to nonclassical radiation even when pumping processes with Poissonian statistics are used. Some applications of the one- atom maser to study the quantum measurement process also are discussed.
A simple model of a maser or laser consisting of a single-mode field coupled to NNN identical two-level atoms is considered. The semiclassical approximation is equivalent to neglecting the statistical correlations between the atoms and the field. The accuracy of this approximation is investigated by writing equations of motion for the correlations. To obtain a complete, self-consistent set of equations, it is necessary to include correlations of the field with itself (related to the coherence of the field) and correlations between different atoms. Relaxations and an energy source are introduced phenomenologically into the equations of motion. They are then solved for the case of steady-state oscillation. It is found that the correlations are smaller than the terms kept in the semiclassical theory by the order of 1 over the number of photons present in the field, larger if thermal photons abound, but smaller if the field relaxation is dominant. Expressions are also found for the amplitude and phase fluctuations of the field. The latter yield a linewidth for the maser oscillator in agreement with earlier calculations, but obtained by a different method.
There are only fistful of systems in physics that can be described by an exact theory from first principles and, at the same time, can be investigated under experimental conditions approaching the idealized theoretical ones. The one-atom-maser or micromaser provides such an example, making a detailed study of the fundamental properties of the atom-field interaction possible. The situation realized in a micromaser is very close to the ideal case of a single two-level atom interacting with a single quantized mode of a cavity field. In the micromaser the atoms have a dual purpose of both pumping the field and also probing it via measurements of the outgoing atoms. Any other means of measuring the field inside the resonator has the detrimental effect of lowering its Q-factor and thereby the photon storage time. The long photon storage time of the resonator allows for the decay of the field to be negligible during the passage of an atom and its interaction with the field. The behavior of atoms in a cavity is governed by the oscillatory exchange of energy between the atoms and the field, which is called Rabi oscillation. For cavity fields in the vacuum and few photon number states (Fock states), Rabi oscillations have been measured in the past. To prevent thermal effects from polluting the pure number states these experiments were performed at low temperatures (below 1 K). However, the observed resolution of the Rabi oscillations measurements was quite disappointing (only about 2% of the predicted theoretical value) and precluded more ambitious experiments like atom-atom correlations or time resolved investigations of the maser field dynamics. The observed contrast of Rabi oscillations can be considered as a figure of merit for the experimental resolution of quantum features of a maser field. Therefore, a high resolution in the measurements of Rabi oscillations is crucial. This thesis describes the methods and improvements applied to enhance the resolution of Rabi oscillations by a factor of 8. The following upgrades and developments proved to be crucial in this work: 1) The base temperature of the cryogenic system was lowered to 0.3 K, i.e. one third of the original value. At the same time, the time during which the system remains at the base temperature was improved by almost of an order of magnitude (to more than 12 h). 2) For the promotion of the atoms to the Rydberg regime new three-step diode laser setup was constructed. The excitation efficiency compared to the old dye laser was increased by two orders. Using top-of-fringe stabilization with new spectroscopic methods, specially designed error detection and feedback schemes as well as state-of-the-art PID regulators the continuous locking of lasers is about 8 h (compared to about 20 min with the old dye laser system). 3) The flexibility of using the three step excitation allows to excite different maser states and for the first time to investigate pure maser transition. 4) Various improvements on the atomic oven and the channeltron detection unit led to the reliable and stable production and detection of the atomic beam. Observed distribution of the atomic beam statistics reaches to within 6% the Poisson limit which is expected in the absence of experimental imperfections. 5) New developed techniques in magnetic field compensation allow to perform such measurements with two orders of magnitude better accuracy compared to the previous experiments. To demonstrate the new capabilities of the apparatus and to apply its improved resolution of quantum fields we performed a previously impossible in-depth analysis of mean photon number and the atomic inversion produced by a micromaser for various detunings between the cavity- and atomic resonance frequency.
The field in the micromaser cavity, the atoms which both pump and probe the micromaser, and the detectors that determine the outgoing states of the atoms are treated as a single system in order to derive a nonlinear master equation for the field in the micromaser cavity which takes the effect of undetected atoms into account. Analytic solutions for this master equation are found for both phase-insensitive and phase-sensitive detection. These solutions can be used to explicitly show the back-action effects that measurement has on the spectrum of the micromaser. In addition, these solutions are used to find analytic expressions for the mean number of successive detector clicks of the same kind as well as atom-atom and photon-photon correlation functions. In this way, the analytic solutions are linked to experimentally accessible data.
We review our recent work on the nonclassical radiation field of a one-atom maser. The maser cavity is cooled to 0.5 K to exclude thermal photons and has a quality factor of 3 × 10 10 . Velocity-selected Rydberg atoms pump the maser. The field inside the cavity is measured via the fluctuations in the number of atoms leaving the cavity in the lower maser level which are up to 40% below the Poisson level. This corresponds to photon-number fluctuations 70% below the vacuum-state limit. The one-atom maser is the only maser system which leads to nonclassical radiation even when pumping processes with Poissonian statistics are used. We analyse and propose new experiments based on the one-atom maser leading to new studies of the quantum measurement process.