We discuss the detection of field quadrature fluctuations in conditional homodyne detection experiments and possible sources of error in such an experiment. We also present modifications to these experiments to help eliminate such errors and extend their range of applicability.
Summary form only given. The squeezing of an optical field is normally observed in the frequency domain using balanced homodyne detection to measure the fluctuation variance of a selected quadrature amplitude. The scheme amounts to a measurement of sub-Poissonian photon statistics and is sensitive to efficiencies as any such unconditional measurement is. Conditional measurements are independent of efficiencies. We propose a conditional homodyne detection scheme for observing the amplitude fluctuations of squeezed light. The central idea is to sample the photocurrent by triggering on a photon count and hence realize an efficiency independent measurement that resolves the quantum fluctuations in time. Our scheme directly measures the correlation function.
A simple but rigorous analysis of the important sources of noise in homodyne detection is presented. Output noise and signal-to-noise ratios are compared for direct detection, conventional (one-port) homodyning, and two-port homodyning, in which one monitors both output ports of a 50-50 beam splitter. It is shown that two-port homodyning is insensitive to local-oscillator quadrature-phase noise and hence provides (1) a means of detecting reduced quadrature-phase fluctuations (squeezing) that is perhaps more practical than one-port homodyning and (2) an output signal-to-noise ratio that can be a modest to significant improvement over that of one-port homodyning and direct detection.