Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Hyperfine Interactions

Designing an RFQ ring trap for antiproton confinement and trapping and laser cooling Mg+ ions

Xu Feng, M. Rathlev, Jeffrey Scott Hangst, Helge V. Knudsen, Michael H. Holzscheiter

Published Dec 1, 1996• 2 citations
Publisher
DOI
10.1007/bf02059935

Related papers

Towards sympathetic cooling of trapped ions with laser-cooled Mg + ions for mass spectrometry and laser spectroscopy

Radu Cazan, Christopher Geppert, W. Nörtershäuser +1 more

Springer eBooks•Jan 1, 2010•0 citations

Laser Cooling of Mg+ Ions and First Experimental Observation of Resonant Particle Transport in a Penning Trap

Jin Yu, Michel Desaintfuscien, F. Plumelle

Springer series in optical sciences/SPringer series in optical sciences•Jan 1, 1987•0 citations

Studies of trapped and laser cooled magnesium ions

David John Bate

•Jan 1, 1991•0 citations

Laser cooling of externally produced Mg ions in a Penning trap for sympathetic cooling of highly charged ions

Zoran Andelkovic, Radu Cazan, W. Nörtershäuser +7 more

We have performed laser cooling of Mg${}^{+}$ ions confined in a Penning trap. The externally produced ions were captured in flight, stored, and laser cooled. Laser-induced fluorescence was observed perpendicular to the cooling laser axis. Optical detection down to the single-ion level together with the electronic detection of the ion oscillations inside the Penning trap have been used to acquire information on the ion storage time, ion number, and ion temperature. Evidence for the formation of ion crystals has been observed. These investigations are an important prerequisite for the sympathetic cooling of simultaneously stored highly charged ions and the precision laser spectroscopy of forbidden transitions in these.

arXiv:1211.2106•Physical Review A•Mar 27, 2013•48 citations

Cooling and Mass-Analysis of Molecules Using Laser-Cooled Atoms

Takashi Baba, Izumi Waki

This paper presents the first sympathetic cooling of molecular ions using laser-cooled atomic ions. To this end, we developed a novel combination of sympathetic cooling and in situ mass spectroscopy that allows the use of laser-cooled atomic ions to detect sympathetically-cooled molecular ions non-destructively. We demonstrate this technique by cooling and mass-analysing ions of ultra-high-vacuum residual gas and externally introduced air in situ with less than 80 ions each, confined in a radio-frequency quadrupole (RFQ). This capability to detect and identify sympathetically-cooled molecules with potentially-high sensitivity in situ in an RFQ should be useful for molecular spectroscopy, chemical analysis and study of cold molecules and clusters.

Japanese Journal of Applied Physics•Sep 1, 1996•85 citations

Towards trapping and laser cooling Ba and La ions

Jessie Hankes, Amanda Nelson, Patrick Banner +1 more

Bulletin of the American Physical Society•Jun 8, 2017•0 citations
We have performed laser cooling of Mg+{}^{+}+ ions confined in a Penning trap. The externally produced ions were captured in flight, stored, and laser cooled. Laser-induced fluorescence was observed perpendicular to the cooling laser axis. Optical detection down to the single-ion level together with the electronic detection of the ion oscillations inside the Penning trap have been used to acquire information on the ion storage time, ion number, and ion temperature. Evidence for the formation of ion crystals has been observed. These investigations are an important prerequisite for the sympathetic cooling of simultaneously stored highly charged ions and the precision laser spectroscopy of forbidden transitions in these.
This paper presents the first sympathetic cooling of molecular ions using laser-cooled atomic ions. To this end, we developed a novel combination of sympathetic cooling and in situ mass spectroscopy that allows the use of laser-cooled atomic ions to detect sympathetically-cooled molecular ions non-destructively. We demonstrate this technique by cooling and mass-analysing ions of ultra-high-vacuum residual gas and externally introduced air in situ with less than 80 ions each, confined in a radio-frequency quadrupole (RFQ). This capability to detect and identify sympathetically-cooled molecules with potentially-high sensitivity in situ in an RFQ should be useful for molecular spectroscopy, chemical analysis and study of cold molecules and clusters.