Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Direct Measurement of the Group Velocity of Light

Hans Günter Danielmeyer, Heinz P Weber

Published May 1, 1971• 20 citations
Publisher

Abstract

We propose and demonstrate a method to directly measure with high accuracy the group velocity of light. We make use of the natural fluctuations of light and determine in a correlation experiment the coincidence of fluctuations of light passing through a sample path and a reference path with known delay. It is shown that this coincidence can be detected by using amplitude interferometers such as a Michelson interferometer, or intensity interferometers. Accuracies of the order of ${10}^{\ensuremath{-}6}$ are practically possible. That is orders of magnitude better than previous methods allow. Using a Nd:glass laser as light source and an intensity interferometer for detecting coincidence, we demonstrate our method by measuring the group velocity of light in water within 2 \ifmmode\times\else\texttimes\fi{} ${10}^{\ensuremath{-}4}$ using a sample length of only 15 cm. The limitations of this new method caused by second-order dispersion are discussed quantitatively; higher-order effects are discussed qualitatively.

DOI
10.1103/physreva.3.1708

Related papers

Measurement of coherence time by fourth-order Interference

Z. Y. Ou, E. C. Gage, Brian E. Magill +1 more

By using an intensity correlation, or photon coincidence, technique and a Mach-Zehnder interferometer with artificially applied phase fluctuations in one arm, we measured the coherence time of a thermal light beam. The light was derived from the filtered fluorescence of a rhodamine 6G dye solution. The two-photon coincidence rate was measured as a function of path difference and was found to dip 50% when the two arms of the interferometer are balanced. The coherence time of ~100 fs is determined from the measured width of the dip and is consistent with the passband of the filters. The method does not require the stability needed in second-order interference measurements, and its time resolution can be much shorter than that of the photodetectors. The theory of this type of fourth-order interference technique is discussed.

Annual Meeting Optical Society of America•Jan 1, 1988•0 citations

Dispersion cancellation in a measurement of the single-photon propagation velocity in glass

Aephraim M. Steinberg, Paul G. Kwiat, R. Y. Chiao

We have demonstrated for the first time that single photons in glass travel at the group velocity, and have observed a novel, nonlocal dispersion-cancellation effect. We used a two-photon interferometer in which a conjugate pair of photons produced in parametric fluorescence travel separate paths and are detected in coincidence after being recombined at a beam splitter. A piece of glass was placed in the path of one of the photons, and a variable delay was adjusted to precisely compensate for it. The single-photon propagation time was thus measured to within approximately 4 fsec.

Physical Review Letters•Apr 20, 1992•271 citations

Simultaneous measurement of group and phase delay between two photons

David A. Branning, Alan L. Migdall, Alexander V. Sergienko

We report on an experiment to determine both the group and phase delays experienced by orthogonally polarized photon pairs traveling through a birefringent medium. Both types of delay are determined from the same set of coincidence-counting data. The experiment is based on an interference technique using two-photon multipath indistinguishability to produce an interference feature. Earlier work has shown that this interference feature can be used to measure the group velocity of single-photon wave packets in dielectric media. In the current work, the two-photon interferometer has been modified to produce an additional interference feature that is sensitive to the phase velocity of the light. We have used this technique to simultaneously measure the group delay in crystal quartz with a precision of 0.1 fs and the phase delay with a precision of 8 attoseconds. Our analysis clarifies the effects of group and phase delays and shows the unexpected result that dispersive temporal broadening, which is well known to be canceled for the original interferometer setup, is not canceled for this type of ``postponed compensation'' interferometer.

Physical Review A•Nov 10, 2000•66 citations

Four-femtosecond propagation time measurement on single photons and nonlocal cancellation of group velocity dispersion

Aephraim M. Steinberg, Paul G. Kwiat, R. Y. Chiao

In the process of spontaneous parametric down-conversion, conjugate pairs of broadband photons are emitted simultaneously from a nonlinear crystal. We use coincidence detection in a fourth-order interferometer to measure the propagation delay of one photon with respect to that of its conjugate. One photon of every pair enters each arm of the interferometer, and when the path-length difference is adjusted such that the two photons meet essentially simultaneously at the output beam splitter, a dip is observed in the coincidence rate between photon counters placed at the two output ports. In our experiment, the rms width of this dip is 15 fs. By placing various dielectric media in the path of one of the photons and then adjusting the free-space path lengths until the coincidence dip reappears, we have measured the propagation time of single photons and found it to agree with predictions based on the group velocity.1 Because of a surprising quantum-mechanical effect, group-velocity dispersion cancels out, such that the expected wave packet broadening has essentially no effect on the high time resolution of this technique.2

Annual Meeting Optical Society of America•Jan 1, 1992•0 citations

Research of the impact of group velocity dispersion on the second-order correlation of entangled light field

Han Xiao-chun, Jingzheng Huang, Chen Fang +1 more

In the experiment presented in the paper, HBT (Hanbury-Brown and Twiss) interferometer is used to measure the second-order correlation function (G2) for two entangled photons, denoted as signal and idle ones, generated by the spontaneous parametric down-conversion process. When an extra optical fiber is inserted in the signal's path, the arrival times of these two photons are different, so that the length of the fiber can be estimated by measuring the time offset in the G2 function.#br#As the laser light we used is not monochromatic, the experimental result is affected by the group velocity dispersion (GVD). Light of different wavelength has different velocity and leads to different travelling time in the fiber. Through calculation, we find that the G2 function of each wavelength has the same shape but different center time offset. Thus, the final G2 function, as a superimposition of the functions with different wavelengths, is broadened in a long-distance measurement, which seriously reduces the estimation accuracy. We analyze this phenomenon in both theory and experiment, and the experimental results fit our theoretical simulations quite well.#br#In the theoretical analysis, we find that the group velocity dispersion introduces an additional time offset to the final G2 function which is proportional to the total time offset. In our experiment, this additional time offset is about 1% of the total time offset. In particular, this effect results in a 63600 ps extra time offset, which can be compensated in post process, with a time accuracy of about 1 ps.#br#This paper focuses on the G2 function affected by the group velocity dispersion, and also calculates the additional time offset produced by group velocity dispersion, and thus gives a method to compensate the additional time offset through calculation.

Acta Physica Sinica•Jan 1, 2015•0 citations

Measurement of polarization group velocity dispersion in optically active and organic materials using entangled photons

Alexander V. Sergienko, Mete Atatüre, Bahaa E. A. Saleh +2 more

Summary form only given. We adapted a quantum interferometric technique for measuring the relative delay between two oppositely polarized photons to measure the delay between right and left-polarized light in optically active materials. Measuring the delay of photons passing through a solution of organic molecules can be used to measure its concentration. A test to measure the delay between right- and left-polarized light passing through glucose is performed to demonstrate the feasibility of this method to measure concentrations of similar molecules. The setup measures the interference (intensity correlation) of two entangled photons of opposite polarization after passing through a sample.

Conference on Lasers and Electro-Optics•Jan 20, 2003•0 citations
We propose and demonstrate a method to directly measure with high accuracy the group velocity of light. We make use of the natural fluctuations of light and determine in a correlation experiment the coincidence of fluctuations of light passing through a sample path and a reference path with known delay. It is shown that this coincidence can be detected by using amplitude interferometers such as a Michelson interferometer, or intensity interferometers. Accuracies of the order of 10\ensuremath−6{10}^{\ensuremath{-}6}10\ensuremath−6 are practically possible. That is orders of magnitude better than previous methods allow. Using a Nd:glass laser as light source and an intensity interferometer for detecting coincidence, we demonstrate our method by measuring the group velocity of light in water within 2 \ifmmode\times\else\texttimes\fi{} 10\ensuremath−4{10}^{\ensuremath{-}4}10\ensuremath−4 using a sample length of only 15 cm. The limitations of this new method caused by second-order dispersion are discussed quantitatively; higher-order effects are discussed qualitatively.
By using an intensity correlation, or photon coincidence, technique and a Mach-Zehnder interferometer with artificially applied phase fluctuations in one arm, we measured the coherence time of a thermal light beam. The light was derived from the filtered fluorescence of a rhodamine 6G dye solution. The two-photon coincidence rate was measured as a function of path difference and was found to dip 50% when the two arms of the interferometer are balanced. The coherence time of ~100 fs is determined from the measured width of the dip and is consistent with the passband of the filters. The method does not require the stability needed in second-order interference measurements, and its time resolution can be much shorter than that of the photodetectors. The theory of this type of fourth-order interference technique is discussed.
We have demonstrated for the first time that single photons in glass travel at the group velocity, and have observed a novel, nonlocal dispersion-cancellation effect. We used a two-photon interferometer in which a conjugate pair of photons produced in parametric fluorescence travel separate paths and are detected in coincidence after being recombined at a beam splitter. A piece of glass was placed in the path of one of the photons, and a variable delay was adjusted to precisely compensate for it. The single-photon propagation time was thus measured to within approximately 4 fsec.
We report on an experiment to determine both the group and phase delays experienced by orthogonally polarized photon pairs traveling through a birefringent medium. Both types of delay are determined from the same set of coincidence-counting data. The experiment is based on an interference technique using two-photon multipath indistinguishability to produce an interference feature. Earlier work has shown that this interference feature can be used to measure the group velocity of single-photon wave packets in dielectric media. In the current work, the two-photon interferometer has been modified to produce an additional interference feature that is sensitive to the phase velocity of the light. We have used this technique to simultaneously measure the group delay in crystal quartz with a precision of 0.1 fs and the phase delay with a precision of 8 attoseconds. Our analysis clarifies the effects of group and phase delays and shows the unexpected result that dispersive temporal broadening, which is well known to be canceled for the original interferometer setup, is not canceled for this type of ``postponed compensation'' interferometer.
In the process of spontaneous parametric down-conversion, conjugate pairs of broadband photons are emitted simultaneously from a nonlinear crystal. We use coincidence detection in a fourth-order interferometer to measure the propagation delay of one photon with respect to that of its conjugate. One photon of every pair enters each arm of the interferometer, and when the path-length difference is adjusted such that the two photons meet essentially simultaneously at the output beam splitter, a dip is observed in the coincidence rate between photon counters placed at the two output ports. In our experiment, the rms width of this dip is 15 fs. By placing various dielectric media in the path of one of the photons and then adjusting the free-space path lengths until the coincidence dip reappears, we have measured the propagation time of single photons and found it to agree with predictions based on the group velocity.1 Because of a surprising quantum-mechanical effect, group-velocity dispersion cancels out, such that the expected wave packet broadening has essentially no effect on the high time resolution of this technique.2
In the experiment presented in the paper, HBT (Hanbury-Brown and Twiss) interferometer is used to measure the second-order correlation function (G2) for two entangled photons, denoted as signal and idle ones, generated by the spontaneous parametric down-conversion process. When an extra optical fiber is inserted in the signal's path, the arrival times of these two photons are different, so that the length of the fiber can be estimated by measuring the time offset in the G2 function.#br#As the laser light we used is not monochromatic, the experimental result is affected by the group velocity dispersion (GVD). Light of different wavelength has different velocity and leads to different travelling time in the fiber. Through calculation, we find that the G2 function of each wavelength has the same shape but different center time offset. Thus, the final G2 function, as a superimposition of the functions with different wavelengths, is broadened in a long-distance measurement, which seriously reduces the estimation accuracy. We analyze this phenomenon in both theory and experiment, and the experimental results fit our theoretical simulations quite well.#br#In the theoretical analysis, we find that the group velocity dispersion introduces an additional time offset to the final G2 function which is proportional to the total time offset. In our experiment, this additional time offset is about 1% of the total time offset. In particular, this effect results in a 63600 ps extra time offset, which can be compensated in post process, with a time accuracy of about 1 ps.#br#This paper focuses on the G2 function affected by the group velocity dispersion, and also calculates the additional time offset produced by group velocity dispersion, and thus gives a method to compensate the additional time offset through calculation.
Summary form only given. We adapted a quantum interferometric technique for measuring the relative delay between two oppositely polarized photons to measure the delay between right and left-polarized light in optically active materials. Measuring the delay of photons passing through a solution of organic molecules can be used to measure its concentration. A test to measure the delay between right- and left-polarized light passing through glucose is performed to demonstrate the feasibility of this method to measure concentrations of similar molecules. The setup measures the interference (intensity correlation) of two entangled photons of opposite polarization after passing through a sample.