Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Symposium on Frequency Standards and Metrology

ALL-OPTICAL ATOMIC CLOCK BASED ON DARK STATES OF 85 Rb

T. LINDVALL, Mikko Merimaa, Ilkka Juhani Tittonen, E. IKONEN

Published May 1, 2002• 5 citations
Publisher

Abstract

An all-optical RF standard based on dark states of 85 Rb atoms has been developed. With this system we were able to measure ultra-narrow optically induced hyperfine dark resonances below 20 Hz ( Q - value > 1.5 × 10 8 ). The frequency of a signal generator was stabilized to the dark resonance giving a relative frequency stability (square root of Allan variance) of 3.5 × 10 -11 τ -1/2 (1 S < t < 2000 s ). The best stability reached at an integration time of t = 2000 s was 6.4 × 10 -13 , which is sufficient for many high-precision applications. The frequency shifts caused by various experimental parameters were also studied.

DOI
10.1142/9789812777713_0022

Related papers

All-optical atomic clock based on coherent population trapping in ^85Rb

Mikko Merimaa, Thomas Lindvall, Ilkka Juhani Tittonen +1 more

An all-optical microwave frequency standard based on coherent population trapping (CPT) in 85Rb is developed. The CPT resonances are detected by an ordinary edge-emitting diode laser in a simple optical setup. A buffer-gas mixture is carefully optimized to yield a narrow linewidth and a reduced temperature dependence of the resonance frequency. With the developed system we are able to measure ultranarrow optically induced hyperfine CPT resonances at <20 Hz, which is in good agreement with the linewidth calculated from experimental parameters. The frequency of an RF-signal generator has been stabilized to the CPT resonance between the two mF=0 magnetic sublevels. The relative frequency stability (square root of Allan variance) follows a slope of 3.5×10-11 τ-1/2(1 s<τ<2000 s). The best stability of 6.4×10-13 is reached at an integration time of τ=2000 s. This stability is sufficient for many high-precision applications. Frequency-shift measurements were made to evaluate the frequency dependencies on the operation parameters.

Journal of the Optical Society of America B•Feb 1, 2003•132 citations

Compact 780-nm Rb optical clock

Zhendong Chen, Tianyu Liu, Ruoao Yang +9 more

We demonstrated a compact 780 nm rubidium optical clock, which includes an optical frequency standard and an optical frequency comb, with an optical volume of 11.6 liters. Unlike the 778 nm rubidium atomic clocks based on two-photon transition, here, the laser frequency is stabilized to the Rb D2 transition, using modulation transfer spectroscopy. This approach effectively eliminates Doppler background and provides a high signal to noise ratio and high sensitivity. A nearly 300 MHz microwave signal, whose phase exactly tracks that of the optical frequency standard, is generated via the optical frequency comb, yielding a frequency instability of 1.91 E-13 @1 s and 5.29 E-14 @1000 s in the electronic domain. To the best of our knowledge, this is the most precise frequency stabilization result for the first-excited-state transition of alkali metal atoms to date and represents the first optical clock based on this transition. These results offer a promising approach for the development of portable optical clocks.

arXiv:2501.01826•Physical Review Applied•Nov 24, 2025•6 citations

Compact Rb optical frequency standard with 10−15 stability

Shengnan Zhang, Xiaogang Zhang, Jingzhong Cui +7 more

We achieved a low-cost and small-sized Rb optical frequency standard based on 85Rb 5S1/2 → 6P3/2 transition with 10−15 stability, which is comparable with that of the best 532 nm I2 optical frequency standards. In this system, we directly lock the 420 nm diode laser on the 5S1/2 F = 3 → 6P3/2 F′ = 4 hyperfine transition line without an additional Pound-Drever-Hall pre-locking system. The signal-to-noise-ratio reaches as high as 350 000 when the averaging time is at 1 s. Eventually by the fluctuation of the residual error signal after locking, the preliminary stability of the optical frequency standard reaches 1.2×10−14/τ, decreasing to 2.1 × 10−15 at 80 s. It shows potential in stability performance, experimental cost, and system volume compared with the 532 nm I2 optical frequency standard as a wavelength standard. It also opens a door for the achievement of wavelength standards by using higher excited states of alkalies.

Review of Scientific Instruments•Oct 1, 2017•39 citations

An optical atomic clock using 4 D J states of rubidium

Alisher Duspayev, C Owens, Bineet Dash +1 more

Abstract We analyze an optical atomic clock using two-photon 5 S 1 / 2 → 4 D J transitions in rubidium. Four one- and two-color excitation schemes to probe the 4 D 3 / 2 and 4 D 5 / 2 fine-structure states are considered in detail. We compare key characteristics of Rb 4 D J and 5 D 5 / 2 two-photon clocks. The 4 D J clock features a high signal-to-noise ratio due to two-photon decay at favorable wavelengths, low dc electric and magnetic susceptibilities, and minimal black-body shifts. Ac Stark shifts from the clock interrogation lasers are compensated by two-color Rabi-frequency matching. We identify a ‘magic’ wavelength near 1060 nm, which allows for in-trap, Doppler-free clock-transition interrogation with lattice-trapped cold atoms. From our analysis of clock statistics and systematics, we project a quantum-noise-limited relative clock stability at the 10 − 13 / τ ( s ) -level, with integration time τ in seconds, and a relative accuracy of ∼ 10 − 13 . We describe a potential architecture for implementing the proposed clock using a single telecom clock laser at 1550 nm, which is conducive to optical communication and long-distance clock comparisons. Our work could be of interest in efforts to realize small and portable Rb clocks and in high-precision measurements of atomic properties of Rb 4 D J -states.

arXiv:2406.09352•Quantum Science and Technology•Sep 6, 2024•7 citations

The "atomic candle:" progress towards a smart rubidium atomic clock [and application to microwave dielectric measurements]

James C. Camparo

Just as it is possible to stabilize the frequency of an electromagnetic field to an atomic resonance between energy eigenstates, so it is possible to stabilize the intensity or brightness of a field to an atomic Rabi-resonance. We term such a device an "atomic candle." We describe the operation of a microwave atomic candle based on the 0-0 ground state hyperfine transition in /sup 87/Rb, and our experiments examining its stability and sensitivity to various experimental parameters. Specifically, we have measured the microwave power stability of our candle, relative to the peak of the Rabi-resonance, and obtained /spl sigma//sub /spl Delta/P/P/(/spl tau/)=9/spl times/10/sup -7/+10/sup -7//spl radic//spl tau/. Additionally, we examined the Rabi-resonance shift as a function of various experimental parameters including microwave detuning from the 0-0 resonance and resonance-cell temperature. The paper concludes with a discussion of a novel application of the atomic candle: the precision measurement of a material's complex dielectric constant.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Nov 8, 2002•3 citations

Evaluation of the CPT pseudo-resonance scheme for all-optical 87Rb frequency standard

Georgy A. Kazakov, Evelina Breschi, Boris G. Matisov +5 more

We investigate a novel approach to all-optical frequency standards, based on a combination of the coherent population trapping effect and signal discrimination at the maximum of absorption of the probe radiation. The physics underlying this approach is dark resonance splitting caused by interaction of the nuclear magnetic moment with an external magnetic field. Theoretically it has been shown that this approach under ideal conditions can lead to an important enhancement of the clock stability. Here we present an experimental evaluation of the scheme in view its future application in the domain of vapor-cell atomic clocks. The present results point out that high-performances short-term stability can be obtained only with a high spectral quality light source. In contrast, for our compact and low-consumption setup, the shot-noise limited short-term stability calculated is about 10-12τ-1/2, which is comparable to those presently measured for typical CPT-based atomic clocks.

European Frequency and Time Forum•Jan 1, 2006•1 citation
An all-optical RF standard based on dark states of 85 Rb atoms has been developed. With this system we were able to measure ultra-narrow optically induced hyperfine dark resonances below 20 Hz ( Q - value > 1.5 × 10 8 ). The frequency of a signal generator was stabilized to the dark resonance giving a relative frequency stability (square root of Allan variance) of 3.5 × 10 -11 τ -1/2 (1 S < t < 2000 s ). The best stability reached at an integration time of t = 2000 s was 6.4 × 10 -13 , which is sufficient for many high-precision applications. The frequency shifts caused by various experimental parameters were also studied.
An all-optical microwave frequency standard based on coherent population trapping (CPT) in 85Rb is developed. The CPT resonances are detected by an ordinary edge-emitting diode laser in a simple optical setup. A buffer-gas mixture is carefully optimized to yield a narrow linewidth and a reduced temperature dependence of the resonance frequency. With the developed system we are able to measure ultranarrow optically induced hyperfine CPT resonances at <20 Hz, which is in good agreement with the linewidth calculated from experimental parameters. The frequency of an RF-signal generator has been stabilized to the CPT resonance between the two mF=0 magnetic sublevels. The relative frequency stability (square root of Allan variance) follows a slope of 3.5×10-11 τ-1/2(1 s<τ<2000 s). The best stability of 6.4×10-13 is reached at an integration time of τ=2000 s. This stability is sufficient for many high-precision applications. Frequency-shift measurements were made to evaluate the frequency dependencies on the operation parameters.
We demonstrated a compact 780 nm rubidium optical clock, which includes an optical frequency standard and an optical frequency comb, with an optical volume of 11.6 liters. Unlike the 778 nm rubidium atomic clocks based on two-photon transition, here, the laser frequency is stabilized to the Rb D2 transition, using modulation transfer spectroscopy. This approach effectively eliminates Doppler background and provides a high signal to noise ratio and high sensitivity. A nearly 300 MHz microwave signal, whose phase exactly tracks that of the optical frequency standard, is generated via the optical frequency comb, yielding a frequency instability of 1.91 E-13 @1 s and 5.29 E-14 @1000 s in the electronic domain. To the best of our knowledge, this is the most precise frequency stabilization result for the first-excited-state transition of alkali metal atoms to date and represents the first optical clock based on this transition. These results offer a promising approach for the development of portable optical clocks.
We achieved a low-cost and small-sized Rb optical frequency standard based on 85Rb 5S1/2 → 6P3/2 transition with 10−15 stability, which is comparable with that of the best 532 nm I2 optical frequency standards. In this system, we directly lock the 420 nm diode laser on the 5S1/2 F = 3 → 6P3/2 F′ = 4 hyperfine transition line without an additional Pound-Drever-Hall pre-locking system. The signal-to-noise-ratio reaches as high as 350 000 when the averaging time is at 1 s. Eventually by the fluctuation of the residual error signal after locking, the preliminary stability of the optical frequency standard reaches 1.2×10−14/τ, decreasing to 2.1 × 10−15 at 80 s. It shows potential in stability performance, experimental cost, and system volume compared with the 532 nm I2 optical frequency standard as a wavelength standard. It also opens a door for the achievement of wavelength standards by using higher excited states of alkalies.
Abstract We analyze an optical atomic clock using two-photon 5 S 1 / 2 → 4 D J transitions in rubidium. Four one- and two-color excitation schemes to probe the 4 D 3 / 2 and 4 D 5 / 2 fine-structure states are considered in detail. We compare key characteristics of Rb 4 D J and 5 D 5 / 2 two-photon clocks. The 4 D J clock features a high signal-to-noise ratio due to two-photon decay at favorable wavelengths, low dc electric and magnetic susceptibilities, and minimal black-body shifts. Ac Stark shifts from the clock interrogation lasers are compensated by two-color Rabi-frequency matching. We identify a ‘magic’ wavelength near 1060 nm, which allows for in-trap, Doppler-free clock-transition interrogation with lattice-trapped cold atoms. From our analysis of clock statistics and systematics, we project a quantum-noise-limited relative clock stability at the 10 − 13 / τ ( s ) -level, with integration time τ in seconds, and a relative accuracy of ∼ 10 − 13 . We describe a potential architecture for implementing the proposed clock using a single telecom clock laser at 1550 nm, which is conducive to optical communication and long-distance clock comparisons. Our work could be of interest in efforts to realize small and portable Rb clocks and in high-precision measurements of atomic properties of Rb 4 D J -states.
Just as it is possible to stabilize the frequency of an electromagnetic field to an atomic resonance between energy eigenstates, so it is possible to stabilize the intensity or brightness of a field to an atomic Rabi-resonance. We term such a device an "atomic candle." We describe the operation of a microwave atomic candle based on the 0-0 ground state hyperfine transition in /sup 87/Rb, and our experiments examining its stability and sensitivity to various experimental parameters. Specifically, we have measured the microwave power stability of our candle, relative to the peak of the Rabi-resonance, and obtained /spl sigma//sub /spl Delta/P/P/(/spl tau/)=9/spl times/10/sup -7/+10/sup -7//spl radic//spl tau/. Additionally, we examined the Rabi-resonance shift as a function of various experimental parameters including microwave detuning from the 0-0 resonance and resonance-cell temperature. The paper concludes with a discussion of a novel application of the atomic candle: the precision measurement of a material's complex dielectric constant.
We investigate a novel approach to all-optical frequency standards, based on a combination of the coherent population trapping effect and signal discrimination at the maximum of absorption of the probe radiation. The physics underlying this approach is dark resonance splitting caused by interaction of the nuclear magnetic moment with an external magnetic field. Theoretically it has been shown that this approach under ideal conditions can lead to an important enhancement of the clock stability. Here we present an experimental evaluation of the scheme in view its future application in the domain of vapor-cell atomic clocks. The present results point out that high-performances short-term stability can be obtained only with a high spectral quality light source. In contrast, for our compact and low-consumption setup, the shot-noise limited short-term stability calculated is about 10-12τ-1/2, which is comparable to those presently measured for typical CPT-based atomic clocks.