Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Communications

Laser probing of ions confined in a cylindrical radiofrequency trap

F. Plumelle, Michel Desaintfuscien, Jelte Duchene, C. Audoin

Published Jul 1, 1980• 49 citations
Publisher
DOI
10.1016/0030-4018(80)90162-5

Related papers

Probing Ca/sup +/ ions in a miniature trap

Martina Knoop, Mustapha Said Herbane, M. Houssin +3 more

The electric quadrupole transition of confined Ca/sup +/ ions has been proposed as a frequency standard in the visible domain. To access metrologic conditions, we have built a cylindrical miniature trap, allowing to obtain high frequencies of motion and preparing the access to the Lamb-Dicke regime where the first order Doppler broadening is suppressed. Laser cooling and interrogation of the confined ions require lasers at 397 nm and at 729 nm. We propose the generation of these wavelengths using multimode laser diodes and a frequency-doubling set-up.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jan 22, 2003•0 citations

Optical probing of Eu ions confined in an RF trap

Pushpa M. Rao, Anita Gupta

Pramana•Dec 20, 2011•1 citation

Dynamics of Laser-Cooled Ions Confined in Radio - Traps.

A. P. Williams

•Jan 1, 1995•0 citations

COMPARISON OF TWO SINGLE-ION OPTICAL FREQUENCY STANDARDS AT THE SUB-HERTZ LEVEL

Chr. Tamm, T. Schneider, E. Peik

We describe experimental investigations on an optical frequency standard based on a laser cooled 171Yb+ ion confined in a radiofrequency Paul trap. The electric-quadrupole transition from the 2S1/2(F=0) ground state to the 2D3/2(F=2) state at the wavelength of 436 nm is used as the reference transition. The reference transition is probed by a frequency-doubled, frequency-stabilized diode laser and is resolved with a Fourier-limited full halfwidth of approximately 30 Hz. In order to compare two 171Yb+ standards, separate frequency shift and servo systems are employed to stabilise the probe frequency to the reference transition line centers of two independently stored 171Yb+ ions. The present experimental results indicate a relative instability (Allan standard deviation)of the optical frequency difference between the two systems of sigma_y(1000 s)=1.0E-15 and a mean frequency difference of 0.2 Hz. Shifts in the range of several Hertz are observed in the frequency difference if a stationary electric field gradient is superimposed on the radiofrequency trap field. This measurement permits a first experimental estimate of the electric quadrupole moment of the 2D3/2 state of Yb+.

arXiv:physics/0402120•Laser Spectroscopy•Feb 1, 2004•5 citations

Controlling trapped ions without lasers

D. H. Slichter

Bulletin of the American Physical Society•Jun 4, 2020•0 citations

Stray-field-induced quadrupole shift and absolute frequency of the 688-THz Y171b+ single-ion optical frequency standard

Chr. Tamm, S. Weyers, B. Lipphardt +1 more

We report experimental investigations of a single-ion optical frequency standard based on ${^{171}\text{Y}\text{b}}^{+}$. The ion is confined in a cylindrically symmetric radiofrequency Paul trap. The reference transition is the ${^{2}S}_{1/2}(F=0)--{^{2}D}_{3/2}({F}^{\ensuremath{'}}=2)$ electric quadrupole transition at 688 THz. Using a differential measurement scheme, we determine the shift of the reference transition frequency that occurs due to the interaction of the electric quadrupole moment of the ${^{2}D}_{3/2}$ state with the gradient of the electrostatic stray field in the trap. We determine an upper limit for the instability of the quadrupole shift over times between 100 s to 20 h. We also observe the variations in the shift and in the applied stray-field compensation voltages that result from loading a new ion into the trap and during a subsequent storage period of 74 days. This information is utilized to measure the absolute frequency of the reference transition with an uncertainty that is a factor of 3 smaller than that of the previous measurement. Using a fiber laser based optical frequency comb generator and the cesium fountain clock CSF1 of PTB (Physikalisch-Technische Bundesanstalt), the frequency at 300 K temperature is determined as $688\text{ }358\text{ }979\text{ }309\text{ }306.62\ifmmode\pm\else\textpm\fi{}0.73\text{ }\text{Hz}$.

Physical Review A•Oct 6, 2009•103 citations
The electric quadrupole transition of confined Ca/sup +/ ions has been proposed as a frequency standard in the visible domain. To access metrologic conditions, we have built a cylindrical miniature trap, allowing to obtain high frequencies of motion and preparing the access to the Lamb-Dicke regime where the first order Doppler broadening is suppressed. Laser cooling and interrogation of the confined ions require lasers at 397 nm and at 729 nm. We propose the generation of these wavelengths using multimode laser diodes and a frequency-doubling set-up.
We describe experimental investigations on an optical frequency standard based on a laser cooled 171Yb+ ion confined in a radiofrequency Paul trap. The electric-quadrupole transition from the 2S1/2(F=0) ground state to the 2D3/2(F=2) state at the wavelength of 436 nm is used as the reference transition. The reference transition is probed by a frequency-doubled, frequency-stabilized diode laser and is resolved with a Fourier-limited full halfwidth of approximately 30 Hz. In order to compare two 171Yb+ standards, separate frequency shift and servo systems are employed to stabilise the probe frequency to the reference transition line centers of two independently stored 171Yb+ ions. The present experimental results indicate a relative instability (Allan standard deviation)of the optical frequency difference between the two systems of sigma_y(1000 s)=1.0E-15 and a mean frequency difference of 0.2 Hz. Shifts in the range of several Hertz are observed in the frequency difference if a stationary electric field gradient is superimposed on the radiofrequency trap field. This measurement permits a first experimental estimate of the electric quadrupole moment of the 2D3/2 state of Yb+.
We report experimental investigations of a single-ion optical frequency standard based on 171Yb+{^{171}\text{Y}\text{b}}^{+}171Yb+. The ion is confined in a cylindrically symmetric radiofrequency Paul trap. The reference transition is the ${^{2}S}_{1/2}(F=0)--{^{2}D}_{3/2}({F}^{\ensuremath{'}}=2)$ electric quadrupole transition at 688 THz. Using a differential measurement scheme, we determine the shift of the reference transition frequency that occurs due to the interaction of the electric quadrupole moment of the 2D3/2{^{2}D}_{3/2}2D3/2​ state with the gradient of the electrostatic stray field in the trap. We determine an upper limit for the instability of the quadrupole shift over times between 100 s to 20 h. We also observe the variations in the shift and in the applied stray-field compensation voltages that result from loading a new ion into the trap and during a subsequent storage period of 74 days. This information is utilized to measure the absolute frequency of the reference transition with an uncertainty that is a factor of 3 smaller than that of the previous measurement. Using a fiber laser based optical frequency comb generator and the cesium fountain clock CSF1 of PTB (Physikalisch-Technische Bundesanstalt), the frequency at 300 K temperature is determined as $688\text{ }358\text{ }979\text{ }309\text{ }306.62\ifmmode\pm\else\textpm\fi{}0.73\text{ }\text{Hz}$.