Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Symposium on Frequency Standards and Metrology

DEFINITION AND CONSTRUCTION OF NOISE BUDGET IN ATOM INTERFEROMETRY

Erika D’Ambrosio

Published May 1, 2009• 0 citations
Publisher

Abstract

Given the scientific potential of established and evolving quantum technologies and the new proposed detector for gravitational wave astronomy MIGO (Matter-wave Gravitational Wave Observatory) it is timely and beneficial to characterize some "actual" prototype and gather important in-depth knowledge in atom interferometry. Of first and foremost importance is distinguishing the interferometric approach of real space detectors (based on an apparatus layout whose elements are massive optics or diffraction gratings that fix the ends of the interferometer arms) and the inertial sensors based on a superposition of atomic states, where no arm end is assigned by any optics, but rather the superposition starts and ends at given times meanwhile accruing a relative phase between the different momentum states. The studies presented at the VII Symposium on Frequency Standards and Metrology aim at identifying the potential and sensitivity limits of atom interferometers, based on demonstrated concepts. Their sensitivity is determined by the competition between the signal induced by various disturbances versus that induced by the external fields of interest; the effects depend on the configuration, since different schemes respond differently to the same excitations. The result is a feasibility exploration that demonstrates the actual capability of operating systems. It identifies both the properties and limitations that are characteristic of atom interferometers. The behaviour of such systems must be fully understood in order to have a basis for the development of the next generation of atom interferometers, as detectors applicable in tests of general relativity and as sensors of gravitational waves.

DOI
10.1142/9789812838223_0062

Related papers

Atom interferometry for tests of general relativity

Loriani Fard

The search for a fundamental, self-consistent theoretical framework to cover phenomena over all energy scales is possibly the most challenging quest of contemporary physics. Approaches to reconcile quantum mechanics and general relativity entail the modification of their foundations such as the equivalence principle. This corner stone of general relativity is suspected to be violated in various scenarios and is therefore under close scrutiny. Experiments based on the manipulation of cold atoms are excellently suited to challenge its different facets. Freely falling atoms constitute ideal test masses for tests of the universality of free fall in interferometric setups. Moreover, the superposition of internal energy eigenstates provides the notion of a clock, which allows to perform tests of the gravitational redshift. Furthermore, as atom interferometers constitute outstanding phasemeters, they hold the promise to detect gravitational waves, another integral aspect of general relativity. In recent years, atom interferometers have developed into versatile sensors with excellent accuracy and stability, and allow to probe physics at the interface of quantum mechanics and general relativity without classical analog. In this thesis, various aspects regarding tests of general relativity with atom interferometry have been theoretically investigated. This includes the analysis of fundamental effects as well as feasibility studies of experimental configurations. The work is partially focussed on a space-borne mission scenario for a dedicated quantum test of the universality of free fall beyond state-of-the-art by dropping matter waves of different elements. To enable the target accuracy at the level of 10^(−17), a compensation scheme has been developed and discussed, mitigating the detrimental effects of imperfect test mass co-location upon release and relaxing the requirements on the source preparation by several orders of magnitude. In addition, it was demonstrated that the careful design of quantum degenerate sources is indispensable for these experiments, requiring tailored schemes to prepare miscible binary sources. The possibility to test the gravitational redshift with atom interferometers has also been examined in this thesis and connected to the ideas of clock interferometry. With the proof that closed light pulse atom interferometers without transitions between internal internal states are not sensitive to gravitational time dilation, an ongoing scientific debate has been resolved. Instead, certain configurations were shown to implement a quantum version of the special-relativistic twin paradox, for which an experiment has been proposed. Finally, requirements on atomic sources and atom optics for scenarios of gravitational wave detection on ground and in space have been investigated.

•Jan 1, 2020•0 citations

Classes and configurations of atom interferometers

Erika D’Ambrosio

We establish the fundamental properties of two classes of interferometers: those forming a pattern in momentum space, based on the superposition of two different momentum states and described by their relative propagation, and those forming a pattern in real space, based on two or more interferometer arms and described by the propagation between their local ends. These two classes are characterized by different sensitivity functions and different noise sources; we will compare the sensitivity functions of two possible configurations of atom interferometer and identify the most promising realization, with a view to applications to tests of general relativity and investigations of alterations of the spacetime curvature.

Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D. Particles and fields•Feb 13, 2009•1 citation

UNDERGROUND AND AIRBORNE MATTER-WAVE INERTIAL SENSORS

Philippe Bouyer

Matter-wave inertial sensing relies on the capability of manipulating the coherent wave nature of matter to build an interferometer and accurately measure a phase difference. Since the massive particle associated to the matter wave senses inertial effects, the interferometer represents an accurate inertial probe. Atom interferometers have benefited from the outstanding developments of laser-cooling techniques and reached accuracies comparable to those of inertial sensors based on optical interferometry. Thanks to their long term stability, they offer a breakthrough advance in accelerometry, gyroscopy and gravimetry, for applications to inertial guidance, geoid determinations, geophysics and metrology. They are also excellent candidates for laboratory-based tests of general relativity that could compete with the current tests using astronomical or macroscopic bodies. For example, they may provide new answers to the question of whether the free fall acceleration of a particle is universal, i.e. independent of its internal composition and quantum properties. We report here the first operation of an airborne quantum inertial sensor. We highlight their promising applications to inertial navigation and Earth observation. We also describe the improvement of the quantum sensor sensitivity in weightlessness, and discuss the possibility to conduct airborne or spaceborne tests of the Universality of Free Fall with quantum objects. We finally describe a matter-wave laser based interferometric gravitational antenna (MIGA). This infrastructure will allow for measuring with unprecedented resolution variations of the Earths gravity and of the strain of space-time allowing for enhancing the capabilities of existing and future gravitational wave detectors.

•Jan 26, 2012•0 citations

Quantum noise reduction for gravitational wave detectors: developing realistic interferometer schemes

Mengyao Wang

Gravitational waves are a predication of Einstein's theory of general relativity. After nearly 50 years of effort by the scientific community to construct a detector capable of directly measuring gravitational waves, we expect a breakthrough, the first ever direct measurement of a gravitational wave within the next 5 years. The Advanced LIGO detectors currently under construction are predicted to achieve not only the first detection but to open the field of gravitational-wave astronomy: as an observational window on astrophysics and with an impart on other areas such as cosmology, strong-field gravity, general relativity, and nuclear physics. \n \nThe Advanced LIGO detectors are large-scale laser interferometers that have been designed for very low technical noise so that quantum noise will be limiting their sensitivity over a wide range of their spectrum. Planning for future gravitational wave observatories is already underway and reducing the fundamental quantum noise is considered to be one of the main experimental challenges. My work over the last 4 years has focused on possible new techniques to reduce or circumvent the quantum noise in laser interferometers. \n

•Dec 1, 2013•1 citation

Inertial noise post-correction in atom interferometers measuring the local gravitational acceleration

L. Richardson

Exploiting the quantum nature of atoms through the use of matter-wave interferometry has lead to the development of devices sensitive to, among other things, the local gravitational acceleration. Measurements of the gravitational acceleration have applications ranging from detection of subterranean density di erences to observation of general relativistic e ects. Light-pulse atom interferometers provide an absolute measurement of the gravitational acceleration with a sensitivity competitive and even surpassing the performance of classical sensors. The advantages of atom interferometers as inertial measurement devices have lead to e orts in increasing sensitivity and decreasing the physical dimensions of the measurement head, allowing them to be more transportable for eld use applications. With increasing sensitivity, it becomes more critical to address the noise source limitations a ecting the measurement, speci cally the in uence of ground motion on measurements. Vibrations coupling into the inertial reference add a time varying phase shift uncommon to the paths of the interferometer. This limitation is especially pertinent to transportable atom gravimeters measuring in the eld where inertial noise is typically far higher than in relatively quiet laboratory environments. Within this work, implementation and demonstration of inertial noise post-correction in an atom interferometer is shown within low inertial noise environments and simulated strong motion environments. For a high pulse separation time atom interferometer (T = 78 ms) post-correction yielded an increase in the short term stability from 4.4 x 10 ̄6 m/s2/√Hz to 9.2 x 10 ̄7 m/s2/√Hz. This method was reproduced with a di erent motion sensor to perform post-correction in a high motion environment, generated by introducing additional movement onto the inertial reference. By performing post-correction in the high motion environment, we were able to show an increase of short term stability of γ = 73.8. Current limitations to the post-correction resulted from self noise resolution limitations and spectral resolutions limitations. Beyond corrections with commercially available sensors, this work demonstrates the rst post-correction with a next generation compact optomechanical sensor. This optomechanical sensor is formed from monolithic fused silica capable of sensitively measuring accelerations of a harmonic oscillator test mass, which can be read-out optically. This novel motion sensor has the advantage to any previously shown sensor used for post-correction in the capacity that it is vacuum compatible, insensitive to magnetic elds and has the potential to be implemented directly into the inertial reference. In this work, inertial noise post-correction in a simulated high motion environment is shown, correcting from a short term stability of 8 x 10 ̄3 m/s2/√Hz to 5 x 10 ̄4 m/s2/√Hz. Post-correction was limited by the parasitic cavities within the ber required for optical read-out of the harmonic oscillator displacement and intensity noise uctuations of the source laser. The results shown within this work are congruent with previous works on atom chip gravimeters, both of which help move towards portable hand-held gravimeter measurement heads capable of sensitive inertial measurement.

•Jan 1, 2019•10 citations

SAI: a compact atom interferometer for future space missions

Fiodor Sorrentino, Kai Bongs, Philippe Bouyer +25 more

Atom interferometry represents a quantum leap in the technology for the ultra-precise monitoring of accelerations and rotations and, therefore, for all the science that relies on the latter quantities. These sensors evolved from a new kind of optics based on matter-waves rather than light-waves and might result in an advancement of the fundamental detection limits by several orders of magnitude. Matter-wave optics is still a young, but rapidly progressing science. The Space Atom Interferometer project (SAI), funded by the European Space Agency, in a multi-pronged approach aims to investigate both experimentally and theoretically the various aspects of placing atom interferometers in space: the equipment needs, the realistically expected performance limits and potential scientific applications in a micro-gravity environment considering all aspects of quantum, relativistic and metrological sciences. A drop-tower compatible prototype of a single-axis atom interferometry accelerometer is under construction. At the same time the team is studying new schemes, e.g. based on degenerate quantum gases as source for the interferometer. A drop-tower compatible atom interferometry acceleration sensor prototype has been designed, and the manufacturing of its subsystems has been started. A compact modular laser system for cooling and trapping rubidium atoms has been assembled. A compact Raman laser module, featuring outstandingly low phase noise, has been realized. Possible schemes to implement coherent atomic sources in the atom interferometer have been experimentally demonstrated.

arXiv:1003.1481•Mar 7, 2010•6 citations
Given the scientific potential of established and evolving quantum technologies and the new proposed detector for gravitational wave astronomy MIGO (Matter-wave Gravitational Wave Observatory) it is timely and beneficial to characterize some "actual" prototype and gather important in-depth knowledge in atom interferometry. Of first and foremost importance is distinguishing the interferometric approach of real space detectors (based on an apparatus layout whose elements are massive optics or diffraction gratings that fix the ends of the interferometer arms) and the inertial sensors based on a superposition of atomic states, where no arm end is assigned by any optics, but rather the superposition starts and ends at given times meanwhile accruing a relative phase between the different momentum states. The studies presented at the VII Symposium on Frequency Standards and Metrology aim at identifying the potential and sensitivity limits of atom interferometers, based on demonstrated concepts. Their sensitivity is determined by the competition between the signal induced by various disturbances versus that induced by the external fields of interest; the effects depend on the configuration, since different schemes respond differently to the same excitations. The result is a feasibility exploration that demonstrates the actual capability of operating systems. It identifies both the properties and limitations that are characteristic of atom interferometers. The behaviour of such systems must be fully understood in order to have a basis for the development of the next generation of atom interferometers, as detectors applicable in tests of general relativity and as sensors of gravitational waves.
The search for a fundamental, self-consistent theoretical framework to cover phenomena over all energy scales is possibly the most challenging quest of contemporary physics. Approaches to reconcile quantum mechanics and general relativity entail the modification of their foundations such as the equivalence principle. This corner stone of general relativity is suspected to be violated in various scenarios and is therefore under close scrutiny. Experiments based on the manipulation of cold atoms are excellently suited to challenge its different facets. Freely falling atoms constitute ideal test masses for tests of the universality of free fall in interferometric setups. Moreover, the superposition of internal energy eigenstates provides the notion of a clock, which allows to perform tests of the gravitational redshift. Furthermore, as atom interferometers constitute outstanding phasemeters, they hold the promise to detect gravitational waves, another integral aspect of general relativity. In recent years, atom interferometers have developed into versatile sensors with excellent accuracy and stability, and allow to probe physics at the interface of quantum mechanics and general relativity without classical analog. In this thesis, various aspects regarding tests of general relativity with atom interferometry have been theoretically investigated. This includes the analysis of fundamental effects as well as feasibility studies of experimental configurations. The work is partially focussed on a space-borne mission scenario for a dedicated quantum test of the universality of free fall beyond state-of-the-art by dropping matter waves of different elements. To enable the target accuracy at the level of 10^(−17), a compensation scheme has been developed and discussed, mitigating the detrimental effects of imperfect test mass co-location upon release and relaxing the requirements on the source preparation by several orders of magnitude. In addition, it was demonstrated that the careful design of quantum degenerate sources is indispensable for these experiments, requiring tailored schemes to prepare miscible binary sources. The possibility to test the gravitational redshift with atom interferometers has also been examined in this thesis and connected to the ideas of clock interferometry. With the proof that closed light pulse atom interferometers without transitions between internal internal states are not sensitive to gravitational time dilation, an ongoing scientific debate has been resolved. Instead, certain configurations were shown to implement a quantum version of the special-relativistic twin paradox, for which an experiment has been proposed. Finally, requirements on atomic sources and atom optics for scenarios of gravitational wave detection on ground and in space have been investigated.
We establish the fundamental properties of two classes of interferometers: those forming a pattern in momentum space, based on the superposition of two different momentum states and described by their relative propagation, and those forming a pattern in real space, based on two or more interferometer arms and described by the propagation between their local ends. These two classes are characterized by different sensitivity functions and different noise sources; we will compare the sensitivity functions of two possible configurations of atom interferometer and identify the most promising realization, with a view to applications to tests of general relativity and investigations of alterations of the spacetime curvature.
Matter-wave inertial sensing relies on the capability of manipulating the coherent wave nature of matter to build an interferometer and accurately measure a phase difference. Since the massive particle associated to the matter wave senses inertial effects, the interferometer represents an accurate inertial probe. Atom interferometers have benefited from the outstanding developments of laser-cooling techniques and reached accuracies comparable to those of inertial sensors based on optical interferometry. Thanks to their long term stability, they offer a breakthrough advance in accelerometry, gyroscopy and gravimetry, for applications to inertial guidance, geoid determinations, geophysics and metrology. They are also excellent candidates for laboratory-based tests of general relativity that could compete with the current tests using astronomical or macroscopic bodies. For example, they may provide new answers to the question of whether the free fall acceleration of a particle is universal, i.e. independent of its internal composition and quantum properties. We report here the first operation of an airborne quantum inertial sensor. We highlight their promising applications to inertial navigation and Earth observation. We also describe the improvement of the quantum sensor sensitivity in weightlessness, and discuss the possibility to conduct airborne or spaceborne tests of the Universality of Free Fall with quantum objects. We finally describe a matter-wave laser based interferometric gravitational antenna (MIGA). This infrastructure will allow for measuring with unprecedented resolution variations of the Earths gravity and of the strain of space-time allowing for enhancing the capabilities of existing and future gravitational wave detectors.
Gravitational waves are a predication of Einstein's theory of general relativity. After nearly 50 years of effort by the scientific community to construct a detector capable of directly measuring gravitational waves, we expect a breakthrough, the first ever direct measurement of a gravitational wave within the next 5 years. The Advanced LIGO detectors currently under construction are predicted to achieve not only the first detection but to open the field of gravitational-wave astronomy: as an observational window on astrophysics and with an impart on other areas such as cosmology, strong-field gravity, general relativity, and nuclear physics. \n \nThe Advanced LIGO detectors are large-scale laser interferometers that have been designed for very low technical noise so that quantum noise will be limiting their sensitivity over a wide range of their spectrum. Planning for future gravitational wave observatories is already underway and reducing the fundamental quantum noise is considered to be one of the main experimental challenges. My work over the last 4 years has focused on possible new techniques to reduce or circumvent the quantum noise in laser interferometers. \n
Exploiting the quantum nature of atoms through the use of matter-wave interferometry has lead to the development of devices sensitive to, among other things, the local gravitational acceleration. Measurements of the gravitational acceleration have applications ranging from detection of subterranean density di erences to observation of general relativistic e ects. Light-pulse atom interferometers provide an absolute measurement of the gravitational acceleration with a sensitivity competitive and even surpassing the performance of classical sensors. The advantages of atom interferometers as inertial measurement devices have lead to e orts in increasing sensitivity and decreasing the physical dimensions of the measurement head, allowing them to be more transportable for eld use applications. With increasing sensitivity, it becomes more critical to address the noise source limitations a ecting the measurement, speci cally the in uence of ground motion on measurements. Vibrations coupling into the inertial reference add a time varying phase shift uncommon to the paths of the interferometer. This limitation is especially pertinent to transportable atom gravimeters measuring in the eld where inertial noise is typically far higher than in relatively quiet laboratory environments. Within this work, implementation and demonstration of inertial noise post-correction in an atom interferometer is shown within low inertial noise environments and simulated strong motion environments. For a high pulse separation time atom interferometer (T = 78 ms) post-correction yielded an increase in the short term stability from 4.4 x 10 ̄6 m/s2/√Hz to 9.2 x 10 ̄7 m/s2/√Hz. This method was reproduced with a di erent motion sensor to perform post-correction in a high motion environment, generated by introducing additional movement onto the inertial reference. By performing post-correction in the high motion environment, we were able to show an increase of short term stability of γ = 73.8. Current limitations to the post-correction resulted from self noise resolution limitations and spectral resolutions limitations. Beyond corrections with commercially available sensors, this work demonstrates the rst post-correction with a next generation compact optomechanical sensor. This optomechanical sensor is formed from monolithic fused silica capable of sensitively measuring accelerations of a harmonic oscillator test mass, which can be read-out optically. This novel motion sensor has the advantage to any previously shown sensor used for post-correction in the capacity that it is vacuum compatible, insensitive to magnetic elds and has the potential to be implemented directly into the inertial reference. In this work, inertial noise post-correction in a simulated high motion environment is shown, correcting from a short term stability of 8 x 10 ̄3 m/s2/√Hz to 5 x 10 ̄4 m/s2/√Hz. Post-correction was limited by the parasitic cavities within the ber required for optical read-out of the harmonic oscillator displacement and intensity noise uctuations of the source laser. The results shown within this work are congruent with previous works on atom chip gravimeters, both of which help move towards portable hand-held gravimeter measurement heads capable of sensitive inertial measurement.
Atom interferometry represents a quantum leap in the technology for the ultra-precise monitoring of accelerations and rotations and, therefore, for all the science that relies on the latter quantities. These sensors evolved from a new kind of optics based on matter-waves rather than light-waves and might result in an advancement of the fundamental detection limits by several orders of magnitude. Matter-wave optics is still a young, but rapidly progressing science. The Space Atom Interferometer project (SAI), funded by the European Space Agency, in a multi-pronged approach aims to investigate both experimentally and theoretically the various aspects of placing atom interferometers in space: the equipment needs, the realistically expected performance limits and potential scientific applications in a micro-gravity environment considering all aspects of quantum, relativistic and metrological sciences. A drop-tower compatible prototype of a single-axis atom interferometry accelerometer is under construction. At the same time the team is studying new schemes, e.g. based on degenerate quantum gases as source for the interferometer. A drop-tower compatible atom interferometry acceleration sensor prototype has been designed, and the manufacturing of its subsystems has been started. A compact modular laser system for cooling and trapping rubidium atoms has been assembled. A compact Raman laser module, featuring outstandingly low phase noise, has been realized. Possible schemes to implement coherent atomic sources in the atom interferometer have been experimentally demonstrated.