Journal of the Korean Physical Society

Combination of magneto-optical trapping and mass spectrometry for calcium-isotope analysis

Kwang-Hoon Ko, Yong Hee Kim, Lim Lee, Taek-Soo Kim, Hyunmin Park, Do-Young Jeong, Kyu‐Ha Jang, Gun‐Sik Park

Published Aug 1, 2013• 0 citations
Publisher

Abstract

A method using a combination of a magneto-optical trap and a mass spectrometer, referred to as atom trap-mass spectrometry (ATMS), is employed for calcium-isotope analysis. A calcium magneto-optical trap with a Zeeman slower is used in the first isotope-selection stage of the ATMS. The trapped calcium isotope is ionized by using a frequency-doubled Nd:YAG laser, and the photoions are analyzed using a time-of-flight mass spectrometer. The isotope-selection characteristics of the combination method and further improvements in the method are discussed in this work.

DOI
10.3938/jkps.63.927

Related papers

Single-atom detection of calcium isotopes by atom-trap trace analysis

Steven Hoekstra, A. K. Mollema, Reinhard Morgenstern +2 more

We demonstrate a combination of an isotopically purified atom beam and a magneto-optical trap which enables single-atom detection of all stable isotopes of calcium (40, 42, 43, 44, 46, and 48). These isotopes range in abundance from 96.9% $(^{40}\mathrm{Ca})$ to 0.004% $(^{46}\mathrm{Ca})$. The trap is loaded from an atomic beam which is decelerated in a Zeeman slower and subsequently deflected over an angle of 30\ifmmode^\circ\else\textdegree\fi{} by optical molasses. The isotope selectivity of the Zeeman slower and the deflection stage is investigated experimentally and compared with Monte Carlo simulations.

arXiv:physics/0501009•Physical Review A•Feb 16, 2005•18 citations

Combination method of atom trap and time-of-flight mass spectrometer for Ca isotope analysis

Kwang-Hoon Ko, Kyu‐Ha Jang, Yong Hee Kim +7 more

The coupling of the atom trap and the time-of-flight mass spectrometer is demonstrated using calcium atom. The design of the acceleration unit is introduced and the isotope selective characteristics of the systems are discussed.

Conference on Lasers and Electro-Optics Pacific Rim (CLEO-PR)•Jun 1, 2013•0 citations

Measurement of the isotope selectivity of the strontium magneto-optical trap by a time-of-flight mass spectrometer

Kwang-Hoon Ko, You-Kyoung Lim, Do-Young Jeong +4 more

The isotope selectivity of the strontium (Sr) magneto-optical trap (MOT) is measured by a time-of-flight (TOF) mass spectrometer. The thermally generated Sr atoms are slowed down by the Zeeman slowing technique and trapped by the magneto-optical method. The trapped atoms are photoionized by the nonresonant two-photon ionization, and the generated ions are analyzed by the TOF mass spectrometer. The isotope selectivity of the MOT is up to approximately 2000 for 86Sr, and the overall selectivity of the system, which consists of the MOT and the mass spectrometer is also discussed.

Journal of the Optical Society of America B•Nov 29, 2006•5 citations

Counting Individual Ca41 Atoms with a Magneto-Optical Trap

Iain D. Moore, K. Bailey, J. P. Greene +6 more

Atom trap trace analysis, a novel method based upon laser trapping and cooling, is used to count individual atoms of $^{41}\mathrm{Ca}$ present in biomedical samples with isotopic abundance levels between ${10}^{\ensuremath{-}8}$ and ${10}^{\ensuremath{-}10}$. The method is calibrated against resonance ionization mass spectrometry, demonstrating good agreement between the two methods. The present system has a counting efficiency of $2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}7}$. Within 1 h of observation time, its $3\mathrm{\text{\ensuremath{-}}}\ensuremath{\sigma}$ detection limit on the isotopic abundance of $^{41}\mathrm{Ca}$ reaches $4.5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}10}$.

arXiv:physics/0310045•Physical Review Letters•Apr 14, 2004•30 citations

Spectroscopy and isotope shifts of the 4s3d 1D2 – 4s5p 1P1 repumping transition in magneto-optically trapped calcium atoms

Umakanth Dammalapati, I. Norris, C. Burrows +2 more

We investigate a repumping scheme for magneto-optically trapped calcium atoms. It is based on excitation of the $4s3{d}^{1}{D}_{2}$--$4s5{p}^{1}{P}_{1}$ transition at $672$ nm with an extended cavity diode laser. The effect of the repumping is approximately a factor of three increase in trap lifetime and a doubling of the trapping efficiency from a Zeeman slowed thermal beam. Added to this, the 672-nm laser repumps atoms from an otherwise dark state to yield an overall increase in detected fluorescence signal from the magneto-optic trap (MOT) of more than an order of magnitude. Furthermore, we report isotope shift measurements of the $672$-nm transition, for the first time, for four naturally occurring even isotopes. Using available charge radii data, the observed shifts, extending up to $4.3$ GHz, display the expected linear dependence in a King plot analysis. The measured shifts are used to determine the isotope shifts of the remaining $^{41,43,46}\mathrm{Ca}$ isotopes. These might be of interest where less abundant isotopes are used enabling isotope selective repumping, resulting in enhanced trapping and detection efficiencies.

Physical Review A•Feb 26, 2010•9 citations

Towards ultrasensitive isotope trace analysis {sup 41}Ca.

Iain D. Moore, K. Bailey, Zheng‐Tian Lu +3 more

An Atom Trap Trace Analysis (ATTA) system based on the technique of laser manipulation of neutral atoms is being developed to count individual {sup 41}Ca atoms present in natural samples with an isotopic abundance of 10{sup -15}. Trapping of all stable calcium isotopes has been demonstrated and single-atom counting has been realized. For the most abundant isotope, {sup 40}Ca (97% isotopic abundance), a magneto-optical trap (MOT) loading rate of 2 x 10{sup 10} atoms/s has been reached at the overall capture efficiency of 1 x 10{sup -4}. System improvements could increase the efficiency by at least an order of magnitude.

•May 6, 2002•0 citations
A method using a combination of a magneto-optical trap and a mass spectrometer, referred to as atom trap-mass spectrometry (ATMS), is employed for calcium-isotope analysis. A calcium magneto-optical trap with a Zeeman slower is used in the first isotope-selection stage of the ATMS. The trapped calcium isotope is ionized by using a frequency-doubled Nd:YAG laser, and the photoions are analyzed using a time-of-flight mass spectrometer. The isotope-selection characteristics of the combination method and further improvements in the method are discussed in this work.
We demonstrate a combination of an isotopically purified atom beam and a magneto-optical trap which enables single-atom detection of all stable isotopes of calcium (40, 42, 43, 44, 46, and 48). These isotopes range in abundance from 96.9% (40Ca)(^{40}\mathrm{Ca})(40Ca) to 0.004% (46Ca)(^{46}\mathrm{Ca})(46Ca). The trap is loaded from an atomic beam which is decelerated in a Zeeman slower and subsequently deflected over an angle of 30\ifmmode^\circ\else\textdegree\fi{} by optical molasses. The isotope selectivity of the Zeeman slower and the deflection stage is investigated experimentally and compared with Monte Carlo simulations.
The isotope selectivity of the strontium (Sr) magneto-optical trap (MOT) is measured by a time-of-flight (TOF) mass spectrometer. The thermally generated Sr atoms are slowed down by the Zeeman slowing technique and trapped by the magneto-optical method. The trapped atoms are photoionized by the nonresonant two-photon ionization, and the generated ions are analyzed by the TOF mass spectrometer. The isotope selectivity of the MOT is up to approximately 2000 for 86Sr, and the overall selectivity of the system, which consists of the MOT and the mass spectrometer is also discussed.
Atom trap trace analysis, a novel method based upon laser trapping and cooling, is used to count individual atoms of 41Ca^{41}\mathrm{Ca}41Ca present in biomedical samples with isotopic abundance levels between ${10}^{\ensuremath{-}8}$ and ${10}^{\ensuremath{-}10}$. The method is calibrated against resonance ionization mass spectrometry, demonstrating good agreement between the two methods. The present system has a counting efficiency of $2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}7}$. Within 1 h of observation time, its $3\mathrm{\text{\ensuremath{-}}}\ensuremath{\sigma}$ detection limit on the isotopic abundance of 41Ca^{41}\mathrm{Ca}41Ca reaches $4.5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}10}$.
We investigate a repumping scheme for magneto-optically trapped calcium atoms. It is based on excitation of the 4s3d1D24s3{d}^{1}{D}_{2}4s3d1D2​--4s5p1P14s5{p}^{1}{P}_{1}4s5p1P1​ transition at 672672672 nm with an extended cavity diode laser. The effect of the repumping is approximately a factor of three increase in trap lifetime and a doubling of the trapping efficiency from a Zeeman slowed thermal beam. Added to this, the 672-nm laser repumps atoms from an otherwise dark state to yield an overall increase in detected fluorescence signal from the magneto-optic trap (MOT) of more than an order of magnitude. Furthermore, we report isotope shift measurements of the 672672672-nm transition, for the first time, for four naturally occurring even isotopes. Using available charge radii data, the observed shifts, extending up to 4.34.34.3 GHz, display the expected linear dependence in a King plot analysis. The measured shifts are used to determine the isotope shifts of the remaining 41,43,46Ca^{41,43,46}\mathrm{Ca}41,43,46Ca isotopes. These might be of interest where less abundant isotopes are used enabling isotope selective repumping, resulting in enhanced trapping and detection efficiencies.
An Atom Trap Trace Analysis (ATTA) system based on the technique of laser manipulation of neutral atoms is being developed to count individual {sup 41}Ca atoms present in natural samples with an isotopic abundance of 10{sup -15}. Trapping of all stable calcium isotopes has been demonstrated and single-atom counting has been realized. For the most abundant isotope, {sup 40}Ca (97% isotopic abundance), a magneto-optical trap (MOT) loading rate of 2 x 10{sup 10} atoms/s has been reached at the overall capture efficiency of 1 x 10{sup -4}. System improvements could increase the efficiency by at least an order of magnitude.