Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Modern Optics

Quantum Theory of High-resolution Length Measurement with a Fabry-Perot Interferometer

M. Ley, R. Loudon

Published Feb 1, 1987• 97 citations
Publisher

Abstract

The quantum limits on measurements of small changes in the length of a Fabry-Perot cavity are calculated. The cavity is modelled by a pair of dissimilar mirrors oriented perpendicular to a one-dimensional axis of infinite extent. The continuous spectrum of spatial modes of the system is derived, and the electromagnetic field is quantized in terms of a continuous set of mode creation and destruction operators. Coherent state and squeezed vacuum-state excitations of the field are characterized by energy flow, or intensity, variables. The determination of small changes in the cavity length by observations of fringe intensity is considered for schemes in which the cavity is simultaneously excited by coherent and squeezed vacuum-state inputs. The contributions to the limiting resolution from photocount and radiation-pressure length uncertainties are evaluated. These properties of the Fabry-Perot cavity are compared with the corresponding results for the Michelson interferometer.

DOI
10.1080/09500348714550251

Related papers

Mode Transformation Properties and Quantum Limits for a Fabry-Perot Interferometer

Alfredo Luis, Luis Lorenzo Sánchez-Soto

A full quantum theory of the Fabry-Perot interferometer is presented. The quantum limits on the determination of small changes in the cavity length are considered, studying the case in which the interferometer is simultaneously excited by coherent and squeezed-vacuum inputs. The contributions to the limiting resolution from photon noise and radiation pressure uncertainty are evaluated in a unified calculation by means of a unitary transformation which relates the input modes to the output modes. These results are compared with the corresponding results for the Michelson interferometer.

Journal of Modern Optics•May 1, 1991•9 citations

Quantum Limit on the Michelson Interferometer used for Gravitational-Wave Detection

R. Loudon

The quantum limitations on measurements of the relative positions of the two mirrors in a Michelson gravity-wave detector are derived. The effects of intensity fluctuations in the two light beams and radiation pressure on the mirrors are modeled in a unified calculation. The radiation-pressure uncertainty in mirror position differs in general from earlier work, but gives agreement for coherent input light.

Physical Review Letters•Sep 21, 1981•114 citations

A Note on the Resonant Modes and Spatial Coherency of a Fabry-Perot Maser Interferometer

G. J. Fan

This communication has considered the case of a Fabry-Perot cavity with light impinging on one end while the field distribution on the other end is observed. It has been shown that if one starts with a wave that can be expanded into the modes of the integral operator, and if the medium in the cavity is passive, more than one mode would be observed at the other end although the amplitude of the dominant mode can be much greater than that of the other modes. It was further shown that if there is present an active medium with sufficient gain there will be only a single mode, and the single mode is necessary and sufficient for complete spatial coherency.

IBM Journal of Research and Development•Jul 1, 1964•4 citations

Quantum theory of interferometric length measurement with inefficient photodetectors

Jessica Gifford, Craig M. Savage

We find an upper bound for the sensitivity of Fabry-P\'erot interferometric length measurements using inefficient photodetectors. This bound applies to all possible quantum-mechanical states of the light entering the interferometer. It applies to standard photodetection, differenced photodetection, and homodyne detection. In the limit of large photon number we identify the optimal detection scheme and input states. They are homodyne detection with a coherent state in one input port, and a nonvacuum quadrature squeezed state in the other. No other quantum states of the input light give better sensitivity, provided that the interferometer output is measured by either photodetection or homodyning, and that the photodetectors are inefficient.

Physical Review A•Feb 1, 1991•1 citation

Quantum-enhanced metrology based on Fabry-Perot interferometer by squeezed vacuum and non-Gaussian detection

Wenfang Li, Jinjin Du, Ruijuan Wen +2 more

We have investigated the transmission spectra of a Fabry-Perot interferometer (FPI) with squeezed vacuum state injection and non-Gaussian detection, including photon number resolving detection and parity detection. In order to show the suitability of the system, parallel studies were made of the performance of two other light sources: coherent state of light and Fock state of light either with classical mean intensity detection or with non-Gaussian detection. This shows that by using the squeezed vacuum state and non-Gaussian detection simultaneously, the resolution of the FPI can go far beyond the cavity standard bandwidth limit based on the current techniques. The sensitivity of the scheme has also been explored and it shows that the minimum detectable sensitivity is better than that of the other schemes.

Journal of Applied Physics•Mar 27, 2014•7 citations

Ultrasensitive optical measurement of thermal and quantum noises

T. Caniard, Tristan Briant, P.-F. Cohadon +2 more

We have developed an experiment of ultrasensitive interferometric measurement of small displacements based on a high-finesse Fabry-Perot cavity. We have observed the internal thermal noise of mirrors and fully characterized their acoustics modes with a sensitivity of 3 × 10 −20 m/Hz 1/2 . This unique sensitivity is a step towards the first observation of the radiation pressure effects and the resulting standard quantum limit in interferometric measurements. Our experiment may become a powerful facility to test quantum noise reduction schemes such as the use of squeezed light or quantum locking of mirrors. As a first result, we present the observation of a cancellation of radiation pressure effects in our cavity. This back-action noise cancellation was first proposed within the framework of gravitational-wave detection with dual resonators, and may drastically improve the sensitivity of such measurements.

Optics and Spectroscopy•Aug 1, 2007•6 citations
The quantum limits on measurements of small changes in the length of a Fabry-Perot cavity are calculated. The cavity is modelled by a pair of dissimilar mirrors oriented perpendicular to a one-dimensional axis of infinite extent. The continuous spectrum of spatial modes of the system is derived, and the electromagnetic field is quantized in terms of a continuous set of mode creation and destruction operators. Coherent state and squeezed vacuum-state excitations of the field are characterized by energy flow, or intensity, variables. The determination of small changes in the cavity length by observations of fringe intensity is considered for schemes in which the cavity is simultaneously excited by coherent and squeezed vacuum-state inputs. The contributions to the limiting resolution from photocount and radiation-pressure length uncertainties are evaluated. These properties of the Fabry-Perot cavity are compared with the corresponding results for the Michelson interferometer.
A full quantum theory of the Fabry-Perot interferometer is presented. The quantum limits on the determination of small changes in the cavity length are considered, studying the case in which the interferometer is simultaneously excited by coherent and squeezed-vacuum inputs. The contributions to the limiting resolution from photon noise and radiation pressure uncertainty are evaluated in a unified calculation by means of a unitary transformation which relates the input modes to the output modes. These results are compared with the corresponding results for the Michelson interferometer.
This communication has considered the case of a Fabry-Perot cavity with light impinging on one end while the field distribution on the other end is observed. It has been shown that if one starts with a wave that can be expanded into the modes of the integral operator, and if the medium in the cavity is passive, more than one mode would be observed at the other end although the amplitude of the dominant mode can be much greater than that of the other modes. It was further shown that if there is present an active medium with sufficient gain there will be only a single mode, and the single mode is necessary and sufficient for complete spatial coherency.
We find an upper bound for the sensitivity of Fabry-P\'erot interferometric length measurements using inefficient photodetectors. This bound applies to all possible quantum-mechanical states of the light entering the interferometer. It applies to standard photodetection, differenced photodetection, and homodyne detection. In the limit of large photon number we identify the optimal detection scheme and input states. They are homodyne detection with a coherent state in one input port, and a nonvacuum quadrature squeezed state in the other. No other quantum states of the input light give better sensitivity, provided that the interferometer output is measured by either photodetection or homodyning, and that the photodetectors are inefficient.
We have investigated the transmission spectra of a Fabry-Perot interferometer (FPI) with squeezed vacuum state injection and non-Gaussian detection, including photon number resolving detection and parity detection. In order to show the suitability of the system, parallel studies were made of the performance of two other light sources: coherent state of light and Fock state of light either with classical mean intensity detection or with non-Gaussian detection. This shows that by using the squeezed vacuum state and non-Gaussian detection simultaneously, the resolution of the FPI can go far beyond the cavity standard bandwidth limit based on the current techniques. The sensitivity of the scheme has also been explored and it shows that the minimum detectable sensitivity is better than that of the other schemes.
We have developed an experiment of ultrasensitive interferometric measurement of small displacements based on a high-finesse Fabry-Perot cavity. We have observed the internal thermal noise of mirrors and fully characterized their acoustics modes with a sensitivity of 3 × 10 −20 m/Hz 1/2 . This unique sensitivity is a step towards the first observation of the radiation pressure effects and the resulting standard quantum limit in interferometric measurements. Our experiment may become a powerful facility to test quantum noise reduction schemes such as the use of squeezed light or quantum locking of mirrors. As a first result, we present the observation of a cancellation of radiation pressure effects in our cavity. This back-action noise cancellation was first proposed within the framework of gravitational-wave detection with dual resonators, and may drastically improve the sensitivity of such measurements.