A direct measurement of the natural lifetime for the (
3p54s)
3P1 state of argon has been made using a modified delayed-coincidence method. Argon atoms are repetitively excited by pulses of electrons. For each pulse, the decaying light signal is sampled for a time $\ensuremath{\Delta}t$ at some delay time
t1 after the excitation is terminated. The exponential decay is then reconstructed as the delay time is changed. Collision effects are not important in the pressure region (5.0\ifmmode\times\else\texttimes\fi{}${10}^{\ensuremath{-}6}$-2.0\ifmmode\times\else\texttimes\fi{}${10}^{\ensuremath{-}4}$ Torr) of the experiment and the effects due to cascading are eliminated by keeping the energy of the bombarding electrons low enough so that excitation of the
3p54p levels is negligible. The measured lifetime is dependent upon the argon pressure, and this effect is attributed to resonance trapping; a value of 21\ifmmode\pm\else\textpm\fi{}2 nsec is obtained for the natural lifetime by using the existing theories of resonance trapping to extrapolate the data to zero pressure.
The lifetimes of the
5p2P23 and
5p2P21 states of
Sr+ and the
6p2P23 and
6p2P21 states of
Ba+ have been measured by the Hanle-effect technique with optical excitation from the ion ground state. (The lifetimes of the
Mg+ 3p2P23 and
Ca+ 4p2P23 states were obtained by the same technique and reported previously.) These
Ca+,
Sr+, and
Ba+ states each decay to a
2D23,25 doublet as well as to the ground
2S21 state, and the branching ratios for these transitions have been measured. The ions were produced by introducing traces of the atomic vapor into an argon discharge. Consequently, the cross sections for collisional depolarization of these
2PJ states due to collisions with argon were also obtained from the measurements. The experimental results are given in Tables I and II. A discussion of the ion-atom collisional depolarization cross sections is included.
The lifetimes of the n
2P1/2 and n
2P3/2 states of thallium, n=7--11, have been determined through measurements of the fluorescence signal resulting from two-photon excitation in an atomic beam. The temporal dependence of the fluorescence signal is determined by solving the equations governing cascade spontaneous fluorescence from higher-lying initial states. It is shown that under conditions applicable to our experiments, the asymptotic decay of the fluorescence is a measure of the lifetime of the initial state. The possibility of self-absorption of the fluorescence within the atomic beam is investigated; it is found to be negligible over the range of thallium densities used in the experiment. Our lifetime measurements for these eight
2P states are compared with other known experimental data and with the results of previous semiempirical calculations.
Two-photon-resonant three-photon ionization of atomic phosphorus is studied in the 298--306-nm wavelength range. P atoms are produced by
Ar+ ion sputtering of an InP solid sample and the photoions are detected by a quadrupole mass spectrometer. The laser power dependence of the 3
p4S3/20--4
4S3/20 two-photon excitation and one-photon ionization of 4
p4S3/20 phosphorus is determined in the 10--200 MW/
cm2 range. The cross section for the ionization step is estimated in the frame of the quantum-defect theory: \ensuremath{\sigma}\ensuremath{\sim}3\ifmmode\times\else\texttimes\fi{}${10}^{\mathrm{\ensuremath{-}}18}$
cm2. The two-photon Rabi frequency ${\mathrm{\ensuremath{\Omega}}}_{\mathit{R}}$ is deduced from the comparison of our experimental results with the extended two-level model developed by Eberly [Phys. Rev. Lett. 42, 1049 (1979)] to describe (m+n) resonant multiphoton ionization processes and with the rate equation approximation analysis. The best fit gives ${\mathrm{\ensuremath{\Omega}}}_{\mathit{R}}$(${\mathrm{s}}^{\mathrm{\ensuremath{-}}1}$)=8
IL(W/
cm2). This value compares relatively well with the theoretical estimate ${\mathrm{\ensuremath{\Omega}}}_{\mathit{R}}$=5.5
IL obtained by limiting the perturbation-theory summation to the dominant intermediate states. The combination of well-characterized
Ar+ ion sputtering of a solid sample with resonant photoionization is used to perform actual trace analysis of materials. For example, 0.5 ppm of phosphorus in a silicium sample was measured by this method with a lateral resolution of \ensuremath{\sim}300 \ensuremath{\mu}m.