Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Optics B Quantum and Semiclassical Optics

Noise reduction in quantum tomography

Giacomo Mauro D’Ariano, Matteo G. A. Paris

Published Apr 1, 2000• 4 citations
Publisher

Abstract

We review the `adaptive tomography' technique, and study its application to the measurement of the field intensity and correlations, and to the reconstruction of the Wigner function of a single-mode radiation field. In both cases, this method strongly reduces statistical errors, thus making homodyne tomography a kind of low-noise universal detector.

DOI
10.1088/1464-4266/2/2/308

Related papers

Adaptive quantum homodyne tomography

Giacomo Mauro D’Ariano, Matteo G. A. Paris

An adaptive optimization technique to improve the precision of quantum homodyne tomography is presented. The method is based on the existence of so-called null functions, which have a zero average for an arbitrary state of radiation. The addition of null functions to the tomographic kernels does not affect their mean values, but changes statistical errors, which can then be reduced by an optimization method that ``adapts'' kernels to homodyne data. Applications to tomography of the density matrix and other relevant field observables are studied in detail.

arXiv:quant-ph/9812028•Physical Review A•Jul 1, 1999•28 citations

Quantum interferences reconstruction with low homodyne detection efficiency

Martina Esposito, Francesco Randi, Kelvin Titimbo +7 more

Optical homodyne tomography consists in reconstructing the quantum state of an optical field from repeated measurements of its amplitude at different field phases (homodyne data). The experimental noise, which unavoidably affects the homodyne data, leads to a detection efficiency $\eta<1$ . The problem of reconstructing quantum states from noisy homodyne data sets prompted an intense scientific debate about the presence or absence of a lower homodyne efficiency bound ( $\eta> 0.5$ ) below which quantum features, like quantum interferences, cannot be retrieved. Here, by numerical experiments, we demonstrate that quantum interferences can be effectively reconstructed also for low homodyne detection efficiency. In particular, we address the challenging case of a Schrödinger cat state and test the minimax and adaptive Wigner function reconstruction technique by processing homodyne data distributed according to the chosen state but with an efficiency $\eta< 0.5$ . By numerically reproducing the Schrödinger’s cat interference pattern, we give evidence that quantum state reconstruction is actually possible in these conditions, and provide a guideline for handling optical tomography based on homodyne data collected by low efficiency detectors.

arXiv:1508.07799•EPJ Quantum Technology•May 4, 2016•6 citations

Latest Developments in Quantum Tomography

Giacomo Mauro D’Ariano

Latest developments in quantum tomography are presented. The method for measuring the state of radiation is derived in a simple group-theoretical framework that allows generalization to arbitrary quantum systems. Some recently developed topics are synthetically reviewed, including tomography of many radiation modes using only one local oscillator, generalization to TV-level systems, and new “adaptive” techniques for noise reduction. A set of newly proposed experiments is presented, based on a conditioned tomographic technique. These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Kluwer Academic Publishers eBooks•Dec 19, 2005•2 citations

Maximum-likelihood algorithm for quantum tomography

Konrad Banaszek

Optical homodyne tomography is discussed in the context of classical image processing. Analogies between these two fields are traced and used to formulate an iterative numerical algorithm for reconstructing the Wigner function from homodyne statistics.

arXiv:quant-ph/9904063•Apr 15, 1999•2 citations

Pulsed homodyne Gaussian quantum tomography with low detection efficiency

Martina Esposito, F Benatti, Roberto Floreanini B +8 more

Pulsed homodyne quantum tomography usually requires a high detection efficiency, limiting its applicability in quantum optics. Here, it is shown that the presence of low detection efficiency ( ) does not prevent the tomographic reconstruction of quantum states of light, specifically, of Gaussian states. This result is obtained by applying the so-called 'minimax' adaptive reconstruction of the Wigner function to pulsed homodyne detection. In particular, we prove, by both numerical and real experiments, that an effective discrimination of different Gaussian quantum states can be achieved. Our finding paves the way to a more extensive use of quantum tomographic methods, even in physical situations in which high detection efficiency is unattainable.

arXiv:1301.2471•New Journal of Physics•Apr 7, 2014•20 citations

Signal-to-noise ratio of preamplified homodyne detection in quantum tomography

Marcelo A. Marchiolli, Salomon Sylvain Mizrahi, V. V. Dodonov

The operational theory of homodyne detection by nonideal detectors, used in quantum tomography, was recently modified in order to incorporate the preamplification (before homodyne detection) of the input signal, thus enabling one to beat the handicap of the lower than 0.5 detector efficiency. In the present work we set expressions for the Mandel $Q$ parameter and the signal-to-noise ratio in terms of the operational (measured) moments of the preamplified homodyne detection formalism. These quantities furnish important information on the statistical properties of the input signal field and the photocounts at the output. We illustrate the theory by considering several kinds of fields (for the input signal) and determine the effects of the preamplification on the output signal-to-noise ratios. Here we essentially verify that (i) the preamplification shifts the statistics towards the super-Poissonian limit, without jeopardizing the capacity of reconstructing a sub-Poissionan input signal, and (ii) the preamplification is more effective, i.e., the rate of increase of the signal-to-noise ratio of the output photocount is larger for low-efficiency detectors than for ideal ones.

Physical Review A•May 1, 1998•9 citations
We review the `adaptive tomography' technique, and study its application to the measurement of the field intensity and correlations, and to the reconstruction of the Wigner function of a single-mode radiation field. In both cases, this method strongly reduces statistical errors, thus making homodyne tomography a kind of low-noise universal detector.
An adaptive optimization technique to improve the precision of quantum homodyne tomography is presented. The method is based on the existence of so-called null functions, which have a zero average for an arbitrary state of radiation. The addition of null functions to the tomographic kernels does not affect their mean values, but changes statistical errors, which can then be reduced by an optimization method that ``adapts'' kernels to homodyne data. Applications to tomography of the density matrix and other relevant field observables are studied in detail.
Optical homodyne tomography consists in reconstructing the quantum state of an optical field from repeated measurements of its amplitude at different field phases (homodyne data). The experimental noise, which unavoidably affects the homodyne data, leads to a detection efficiency η<1\eta<1η<1 . The problem of reconstructing quantum states from noisy homodyne data sets prompted an intense scientific debate about the presence or absence of a lower homodyne efficiency bound ( η>0.5\eta> 0.5η>0.5 ) below which quantum features, like quantum interferences, cannot be retrieved. Here, by numerical experiments, we demonstrate that quantum interferences can be effectively reconstructed also for low homodyne detection efficiency. In particular, we address the challenging case of a Schrödinger cat state and test the minimax and adaptive Wigner function reconstruction technique by processing homodyne data distributed according to the chosen state but with an efficiency η<0.5\eta< 0.5η<0.5 . By numerically reproducing the Schrödinger’s cat interference pattern, we give evidence that quantum state reconstruction is actually possible in these conditions, and provide a guideline for handling optical tomography based on homodyne data collected by low efficiency detectors.
Latest developments in quantum tomography are presented. The method for measuring the state of radiation is derived in a simple group-theoretical framework that allows generalization to arbitrary quantum systems. Some recently developed topics are synthetically reviewed, including tomography of many radiation modes using only one local oscillator, generalization to TV-level systems, and new “adaptive” techniques for noise reduction. A set of newly proposed experiments is presented, based on a conditioned tomographic technique. These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.
Pulsed homodyne quantum tomography usually requires a high detection efficiency, limiting its applicability in quantum optics. Here, it is shown that the presence of low detection efficiency ( ) does not prevent the tomographic reconstruction of quantum states of light, specifically, of Gaussian states. This result is obtained by applying the so-called 'minimax' adaptive reconstruction of the Wigner function to pulsed homodyne detection. In particular, we prove, by both numerical and real experiments, that an effective discrimination of different Gaussian quantum states can be achieved. Our finding paves the way to a more extensive use of quantum tomographic methods, even in physical situations in which high detection efficiency is unattainable.
The operational theory of homodyne detection by nonideal detectors, used in quantum tomography, was recently modified in order to incorporate the preamplification (before homodyne detection) of the input signal, thus enabling one to beat the handicap of the lower than 0.5 detector efficiency. In the present work we set expressions for the Mandel QQQ parameter and the signal-to-noise ratio in terms of the operational (measured) moments of the preamplified homodyne detection formalism. These quantities furnish important information on the statistical properties of the input signal field and the photocounts at the output. We illustrate the theory by considering several kinds of fields (for the input signal) and determine the effects of the preamplification on the output signal-to-noise ratios. Here we essentially verify that (i) the preamplification shifts the statistics towards the super-Poissonian limit, without jeopardizing the capacity of reconstructing a sub-Poissionan input signal, and (ii) the preamplification is more effective, i.e., the rate of increase of the signal-to-noise ratio of the output photocount is larger for low-efficiency detectors than for ideal ones.