Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Optics

Measurement of photon indistinguishability to a quantifiable uncertainty using a Hong-Ou-Mandel interferometer

Peter James Thomas, Jessica Y. Cheung, Christopher J. Chunnilall, Malcolm H. Dunn

Published Apr 7, 2010• 6 citations
Publisher

Abstract

We present a method for using the Hong-Ou-Mandel (HOM) interference technique to quantify photon indistinguishability within an associated uncertainty. The method allows the relative importance of various experimental factors affecting the HOM visibility to be identified, and enables the actual indistinguishability, with an associated uncertainty, to be estimated from experimentally measured quantities. A measurement equation has been derived that accounts for the non-ideal performance of the interferometer. The origin of each term of the equation is explained, along with procedures for their experimental evaluation and uncertainty estimation. These uncertainties are combined to give an overall uncertainty for the derived photon indistinguishability. The analysis was applied to measurements from an interferometer sourced with photon pairs from a parametric downconversion process. The measured photon indistinguishably was found to be 0.954+/-0.036 by using the prescribed method.

DOI
10.1364/ao.49.002173

Related papers

Experimental Study of Hong–Ou–Mandel Interference Using Independent Phase Randomized Weak Coherent States

Eleftherios Moschandreou, Jeffrey Ivan Garcia, Brian J. Rollick +3 more

Hong-Ou-Mandel interferometers are valuable tools in many Quantum Information and Quantum Optics applications that require photon indistinguishability. The theoretical limit for the Hong-Ou-Mandel visibility is 0.5 for indistinguishable weak coherent photon states, but several device imperfections may hinder achieving this value experimentally. In this work, we examine the dependence of the interference visibility on various factors, including 1) detector side imperfections due to after-pulses, 2) mismatches in the intensities and states of polarization of the input signals, and 3) the overall intensity of the input signals. We model all imperfections and show that theoretical modeling is in good agreement with the experimental results.

arXiv:1804.02291•Journal of Lightwave Technology•Jun 25, 2018•44 citations

High precision metrology from the fisher information of a Hong-Ou-Mandel interferometer

Ashley Lyons, George C. Knee, Eliot Bolduc +4 more

Quantum interference forces two indistinguishable input photons to depart a beamsplitter in the same (of two possible) spatial output modes; this is known as the Hong-Ou-Mandel (HOM) effect. It provides a quantitative way of measuring the distinguishability between two photons and also has been utilised to determine their relative temporal delays [1, 2]. HOM interferometry offers numerous advantages over its classical counterpart, most importantly it lacks any dependence on the phase of the photons and therefore can potentially provide reliable measurements in environments where the phase is unstable. To date there have been very few investigations on the precision that is achievable with HOM interferometry. Experiments with collinear geometries have yielded sensitivities as low as 0.1fs however these approaches are limited to measurements of birefringence and other polarisation dependent effects [3, 4], as the precision derives from the inherently stable shared path of the photon pairs. Typical non-shared path HOM interferometers exhibit resolution of roughly 1–3 fs (0.3–1 μm).

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2017•0 citations

Estimation of the CHSH Parameter Using HOM Interference

R. A. Brewster, J. Goldhar, Mark B. Morris +2 more

The Clauser–Horne–Shimony–Holt (CHSH) experiment is an essential test of nonlocality in quantum mechanics and can be used to validate the principle of entanglement. In addition to verifying entanglement, the measurable CHSH parameter can also be used to gauge the quality of the entanglement present in a system. The measurement of Hong–Ou–Mandel (HOM) interference is another important fundamental experiment in quantum optics that measures the indistinguishability of a pair of photons. In this article, we demonstrate how the results of a HOM interference experiment, a relatively simple experiment, can be used to obtain an estimate for the value of the CHSH$S$parameter, which is a more complicated measurement. We experimentally demonstrate that the HOM interference technique is capable of providing an estimate of the value of the CHSH parameter that is within one standard deviation of measurement error when spectral impairments are present. We expect that this technique will aid in the calibration of quantum optical systems.

IEEE Transactions on Quantum Engineering•Jan 1, 2022•6 citations

Hong-Ou-Mandel DIP Measurement of two Independent Weak Coherent Pulses

Vivek Kumar, Prasanta Halder, Mukherjee Arka +8 more

Due to the simplicity of Hong-Ou-Mandel (HOM) interferometer setup, it becomes very important in various quantum-based applications, especially when the photon indistinguishability is required such as measurement device independent quantum key distribution (MDI-QKD). In the present work, the HOM experiment setup is designed to study the quantum interference between two indistinguishable photons (frequency, time of arrival and polarization should be same for both photons) coming from two independent laser sources (attenuated laser). The aim is to achieve high visibility as it indicates the photon indistinguishability from two independent sources. Theoretically, the visibility is $50 \%$ for indistinguishable photons from attenuated laser sources but in the experiment, due to various devices imperfections and other factors it is less than 50%. The HOM visibility achieved from our setup is $40 \%$ tested for a distance of 20 km over standard single mode fiber (SMF). The main point to be noticed in this work is that, this experiment is performed using single photon avalanche diode.

ITU Kaleidoscope Academic Conference (ITU K)•Oct 21, 2024•0 citations

Extracting the photon indistinguishability error from measurable quantum observables

F. H. B. Somhorst, Jason Saied, Eleanor Gilbert Rieffel +1 more

Abstract We present a method to extract the photon indistinguishability error from Hong–Ou–Mandel interference measurements, accounting for the combined effects of loss and multiphoton noise that contaminate the single-photon Hilbert space. Our analysis resolves apparent inconsistencies in previous interpretations of such measurements. The reported method applies to a wide range of single-photon sources, including quantum dots.

arXiv:2510.01731•New Journal of Physics•Dec 1, 2025•0 citations

Experimental Verification of Photon Pair Indistinguishability Enhancement via Heralded Post-Selection

Riccardo Checchinato, Jaewon Lee, Fernando Redivo Cardoso +6 more

The Hong-Ou-Mandel (HOM) effect is a direct consequence of the bosonic nature of photons [1], as such, it occurs maximally in the presence of truly indistinguishable photons. Measuring the magnitude of the HOM effect is required to determine the reliability with which a photon source is able to produce indistinguishable photons. Using this method, single photon sources have shown the ability to provide photons with remarkable levels of indistinguishability [2].

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 26, 2023•0 citations
We present a method for using the Hong-Ou-Mandel (HOM) interference technique to quantify photon indistinguishability within an associated uncertainty. The method allows the relative importance of various experimental factors affecting the HOM visibility to be identified, and enables the actual indistinguishability, with an associated uncertainty, to be estimated from experimentally measured quantities. A measurement equation has been derived that accounts for the non-ideal performance of the interferometer. The origin of each term of the equation is explained, along with procedures for their experimental evaluation and uncertainty estimation. These uncertainties are combined to give an overall uncertainty for the derived photon indistinguishability. The analysis was applied to measurements from an interferometer sourced with photon pairs from a parametric downconversion process. The measured photon indistinguishably was found to be 0.954+/-0.036 by using the prescribed method.
Hong-Ou-Mandel interferometers are valuable tools in many Quantum Information and Quantum Optics applications that require photon indistinguishability. The theoretical limit for the Hong-Ou-Mandel visibility is 0.5 for indistinguishable weak coherent photon states, but several device imperfections may hinder achieving this value experimentally. In this work, we examine the dependence of the interference visibility on various factors, including 1) detector side imperfections due to after-pulses, 2) mismatches in the intensities and states of polarization of the input signals, and 3) the overall intensity of the input signals. We model all imperfections and show that theoretical modeling is in good agreement with the experimental results.
Quantum interference forces two indistinguishable input photons to depart a beamsplitter in the same (of two possible) spatial output modes; this is known as the Hong-Ou-Mandel (HOM) effect. It provides a quantitative way of measuring the distinguishability between two photons and also has been utilised to determine their relative temporal delays [1, 2]. HOM interferometry offers numerous advantages over its classical counterpart, most importantly it lacks any dependence on the phase of the photons and therefore can potentially provide reliable measurements in environments where the phase is unstable. To date there have been very few investigations on the precision that is achievable with HOM interferometry. Experiments with collinear geometries have yielded sensitivities as low as 0.1fs however these approaches are limited to measurements of birefringence and other polarisation dependent effects [3, 4], as the precision derives from the inherently stable shared path of the photon pairs. Typical non-shared path HOM interferometers exhibit resolution of roughly 1–3 fs (0.3–1 μm).
The Clauser–Horne–Shimony–Holt (CHSH) experiment is an essential test of nonlocality in quantum mechanics and can be used to validate the principle of entanglement. In addition to verifying entanglement, the measurable CHSH parameter can also be used to gauge the quality of the entanglement present in a system. The measurement of Hong–Ou–Mandel (HOM) interference is another important fundamental experiment in quantum optics that measures the indistinguishability of a pair of photons. In this article, we demonstrate how the results of a HOM interference experiment, a relatively simple experiment, can be used to obtain an estimate for the value of the CHSHSSSparameter, which is a more complicated measurement. We experimentally demonstrate that the HOM interference technique is capable of providing an estimate of the value of the CHSH parameter that is within one standard deviation of measurement error when spectral impairments are present. We expect that this technique will aid in the calibration of quantum optical systems.
Due to the simplicity of Hong-Ou-Mandel (HOM) interferometer setup, it becomes very important in various quantum-based applications, especially when the photon indistinguishability is required such as measurement device independent quantum key distribution (MDI-QKD). In the present work, the HOM experiment setup is designed to study the quantum interference between two indistinguishable photons (frequency, time of arrival and polarization should be same for both photons) coming from two independent laser sources (attenuated laser). The aim is to achieve high visibility as it indicates the photon indistinguishability from two independent sources. Theoretically, the visibility is 50%50 \%50% for indistinguishable photons from attenuated laser sources but in the experiment, due to various devices imperfections and other factors it is less than 50%. The HOM visibility achieved from our setup is 40%40 \%40% tested for a distance of 20 km over standard single mode fiber (SMF). The main point to be noticed in this work is that, this experiment is performed using single photon avalanche diode.