Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physics

Ultrasensitive Absorption Spectroscopy

Julien Mandon, Frans J. M. Harren

Published Nov 28, 2011• 1 citation
Publisher

Abstract

Absorption spectroscopy limited only by quantum noise has been demonstrated over a broad frequency range using laser frequency combs.
DOI
10.1103/physics.4.100

Related papers

Laser-frequency-noise measurement by absorption on an atomic resonance

A.P. Willis, A. I. Ferguson, D. M. Kane

Quantum Electronics and Laser Science Conference•May 22, 1995•0 citations

Fundamental Limits of Optical Frequency Comb Interferometry and Spectroscopy with Coherent, Thermal, and Quantum Light

Tsao, Eugene J.

The measurement and manipulation of coherent optical fields have been transformed by the optical frequency comb. Today, the optical frequency comb grants measurements precise enough to count individual cycles of light as well as the generation of nearly any coherent electromagnetic field from the ultraviolet through the infrared. These capabilities have enabled the most precise realizations and comparisons of time, precision spectroscopy over broad bandwidths, and the ability to convert stable signals between optical and microwave fields–seamlessly connecting the entire electromagnetic spectrum from hertz (100 ) to petahertz (1015). These applications involve the interference of a frequency comb with another coherent light source, such as another frequency comb or a single-frequency continuous-wave laser. However, coherent light represents only one type of light. The vast majority of light emanates from “black bodies” such as stars, which is in a thermal state as opposed to a coherent state, and carries profound information about the universe and humanity’s place within it. Other types of light defy classical electromagnetism and are known as non-classical or quantum light. Such quantum light may play central roles in quantum communication, quantum computation, and quantum-enhanced metrology. In this thesis, the use of the optical frequency comb in the interferometric measurement of thermal and quantum light is investigated, with a focus on assessing fundamental limits to the sensitivity of such measurements. In order to measure thermal light, a technique called dual-comb correlation spectroscopy is explored. This technique entails heterodyne measurement of the field of thermal light and subsequent correlation of the field in time. This process reveals the spectrum of thermal light at high resolution and across broad bandwidths. New theoretical work uncovers previously unknown fundamental limits on sensitivity when measuring realistically weak thermal light. Experimental investigation verifies this scaling and is accompanied by a demonstration of spectroscopy at the equivalent power spectral density of our Sun, realizing a greater than 1000-fold sensitivity increase over past demonstrations of this technique. These insights pave the way for expansion of this technique to comb-based spatial correlation of thermal fields. This advancement would allow for extended baseline synthetic aperture hyperspectral imaging throughout the optical spectrum, facilitating novel and profound observations of the universe. The use of frequency combs for the measurement of quantum light is also investigated. This scenario breaks typical quantum optics assumptions, such as large, mode-matched local oscillators, and necessitates new quantum measurement operators. Such measurement operators are derived, which not only describe homodyne measurements on any quantum state of light with a frequency comb local oscillator, but also indicate that the shot noise limit generally reached in comb-based measurements of coherent light (such as in continuous-wave laser heterodyne and dual-comb spectroscopy) does not correspond to the quadrature or coherent state-overlap description standard in quantum optics. Efforts to experimentally reach this “standard” quantum limit demonstrate a significant improvement in the signal-to-noise ratio over the conventional comb-based shot noise limit, paving the way for lower-power portable optical clocks and quantum-enhanced frequencycomb metrology.

•Nov 20, 2024•0 citations

Advances in quantum-noise-limited Doppler-free optical heterodyne spectroscopy

M. Ducloy

•Apr 26, 1987•0 citations

Entangled Dual-Comb Spectroscopy

Abdulkarim Hariri, Shuai Liu, Haowei Shi +3 more

Optical frequency combs have emerged as a cornerstone for a wide range of areas, including spectroscopy, ranging, optical clocks, time and frequency transfer, waveform synthesis, and communications. However, quantum-mechanical fluctuations of the optical carrier impose fundamental performance limits on the precision of classical optical frequency combs, particularly in their use for interferometry and spectroscopy. Entanglement, as a quintessential quantum resource, allows for surpassing the fundamental limits of classical systems. Here, we introduce entanglement into the realm of optical frequency combs, formulating entangled dual-comb spectroscopy (EDCS) that surmounts the fundamental limits of classical DCS. EDCS capitalizes on tailored entangled structures across the frequency comb, enabling simultaneous detection of all comb lines below the standard quantum limit of classical DCS. Applying EDCS in gas detection, we achieve a 2.6-dB enhancement in signal-to-noise ratio and a 1.7-fold reduction in integration time over classical DCS, rendering EDCS particularly suited for dynamic chemical and biological sensing, where fast, precise measurements subject to power constraints are required. EDCS opens a new avenue for exploiting quantum frequency combs, underscoring their prospects in a plethora of applications in precision metrology, spectroscopy, and timekeeping.

arXiv:2412.19800•Physical Review X•Aug 28, 2025•14 citations

Sensing subhertz optical signals at the quantum noise limit with heterodyne detectors

Boya Xie, Dechao He, Peng Yang +1 more

Sensors and Actuators A Physical•Apr 16, 2022•6 citations

Direct frequency comb spectroscopy in trapped 40Ca+ ions on a dipoleforbidden clock transition

Anne Lisa Wolf, Jonas Morgenweg, Jeroen C. J. Koelemeij +3 more

Optical frequency combs (FCs) have revolutionised ultra-high precision metrology by providing a link between optical and microwave frequencies. While FCs are traditionally used for calibrating a CW probe-laser, also direct frequency comb spectroscopy (DFCS) is possible. We have recently demonstrated the versatility of DFCS performed in the environment of an ion trap, combining the broad spectral range of a Ti: sapphire FC with the feasibility of trapping and (sympathetic) cooling of different ion species. In the presented contribution it is shown that by employing single-ion imaging, this technique can be extended even to dipole-forbidden transitions, despite the low power per unamplified comb mode of ~0.1 μW.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•May 1, 2011•1 citation
The measurement and manipulation of coherent optical fields have been transformed by the optical frequency comb. Today, the optical frequency comb grants measurements precise enough to count individual cycles of light as well as the generation of nearly any coherent electromagnetic field from the ultraviolet through the infrared. These capabilities have enabled the most precise realizations and comparisons of time, precision spectroscopy over broad bandwidths, and the ability to convert stable signals between optical and microwave fields–seamlessly connecting the entire electromagnetic spectrum from hertz (100 ) to petahertz (1015). These applications involve the interference of a frequency comb with another coherent light source, such as another frequency comb or a single-frequency continuous-wave laser. However, coherent light represents only one type of light. The vast majority of light emanates from “black bodies” such as stars, which is in a thermal state as opposed to a coherent state, and carries profound information about the universe and humanity’s place within it. Other types of light defy classical electromagnetism and are known as non-classical or quantum light. Such quantum light may play central roles in quantum communication, quantum computation, and quantum-enhanced metrology. In this thesis, the use of the optical frequency comb in the interferometric measurement of thermal and quantum light is investigated, with a focus on assessing fundamental limits to the sensitivity of such measurements. In order to measure thermal light, a technique called dual-comb correlation spectroscopy is explored. This technique entails heterodyne measurement of the field of thermal light and subsequent correlation of the field in time. This process reveals the spectrum of thermal light at high resolution and across broad bandwidths. New theoretical work uncovers previously unknown fundamental limits on sensitivity when measuring realistically weak thermal light. Experimental investigation verifies this scaling and is accompanied by a demonstration of spectroscopy at the equivalent power spectral density of our Sun, realizing a greater than 1000-fold sensitivity increase over past demonstrations of this technique. These insights pave the way for expansion of this technique to comb-based spatial correlation of thermal fields. This advancement would allow for extended baseline synthetic aperture hyperspectral imaging throughout the optical spectrum, facilitating novel and profound observations of the universe. The use of frequency combs for the measurement of quantum light is also investigated. This scenario breaks typical quantum optics assumptions, such as large, mode-matched local oscillators, and necessitates new quantum measurement operators. Such measurement operators are derived, which not only describe homodyne measurements on any quantum state of light with a frequency comb local oscillator, but also indicate that the shot noise limit generally reached in comb-based measurements of coherent light (such as in continuous-wave laser heterodyne and dual-comb spectroscopy) does not correspond to the quadrature or coherent state-overlap description standard in quantum optics. Efforts to experimentally reach this “standard” quantum limit demonstrate a significant improvement in the signal-to-noise ratio over the conventional comb-based shot noise limit, paving the way for lower-power portable optical clocks and quantum-enhanced frequencycomb metrology.
Optical frequency combs have emerged as a cornerstone for a wide range of areas, including spectroscopy, ranging, optical clocks, time and frequency transfer, waveform synthesis, and communications. However, quantum-mechanical fluctuations of the optical carrier impose fundamental performance limits on the precision of classical optical frequency combs, particularly in their use for interferometry and spectroscopy. Entanglement, as a quintessential quantum resource, allows for surpassing the fundamental limits of classical systems. Here, we introduce entanglement into the realm of optical frequency combs, formulating entangled dual-comb spectroscopy (EDCS) that surmounts the fundamental limits of classical DCS. EDCS capitalizes on tailored entangled structures across the frequency comb, enabling simultaneous detection of all comb lines below the standard quantum limit of classical DCS. Applying EDCS in gas detection, we achieve a 2.6-dB enhancement in signal-to-noise ratio and a 1.7-fold reduction in integration time over classical DCS, rendering EDCS particularly suited for dynamic chemical and biological sensing, where fast, precise measurements subject to power constraints are required. EDCS opens a new avenue for exploiting quantum frequency combs, underscoring their prospects in a plethora of applications in precision metrology, spectroscopy, and timekeeping.
Optical frequency combs (FCs) have revolutionised ultra-high precision metrology by providing a link between optical and microwave frequencies. While FCs are traditionally used for calibrating a CW probe-laser, also direct frequency comb spectroscopy (DFCS) is possible. We have recently demonstrated the versatility of DFCS performed in the environment of an ion trap, combining the broad spectral range of a Ti: sapphire FC with the feasibility of trapping and (sympathetic) cooling of different ion species. In the presented contribution it is shown that by employing single-ion imaging, this technique can be extended even to dipole-forbidden transitions, despite the low power per unamplified comb mode of ~0.1 μW.