This paper reports an investigation of parametric frequency conversion in a vapor of
Rb87 atoms in which nearly resonant optical waves are coupled with microwaves at the ground-state hyperfine-structure (hfs) frequency of
Rb87 by the nonlinear susceptibilities of
Rb87 vapor. These nonlinear susceptibilities are greatly enhanced by optical pumping of the ground-state hfs levels of
Rb87 and by using nearly resonant light. The frequency-conversion process generates optical sideband waves which are separated in frequency from the carrier light waves by the ground-state hfs frequency of
Rb87 (6.835 GHz). These sidebands have been directly observed in the spectral profiles of
Rb85 resonance light which had passed through
Rb87 vapor. The conversion efficiency of power from the carrier waves to the sideband waves in a 45-cm length of vapor was greater than 1%. The observed behavior of the sidebands is in excellent qualitative agreement with the predictions of a semiclassical theory.
A scalar magnetic field sensor based on a millimeter-size Rb87 vapor cell is described. The magnetometer uses nearly copropagating pump and probe laser beams, amplitude modulation of the pump beam, and detection through monitoring the polarization rotation of the detuned probe beam. The circularly polarized pump laser resonantly drives a spin precession in the alkali atoms at the Larmor frequency. A modulation signal on the probe laser polarization is detected with a lock-in amplifier. Since the Larmor precession is driven all-optically, potential cross talk between sensors is minimized. And since the pump light is turned off during most of the precession cycle, large offsets of the resonance, typically present in a single-beam Bell–Bloom scheme, are avoided. At the same time, relatively high sensitivities can be reached even in millimeter-size vapor cells: The magnetometer achieves a sensitivity of 1 pT/Hz1/2 in a sensitive volume of 16 mm3, limited by environmental noise. When a gradiometer configuration is used to cancel the environmental noise, the magnetometer sensitivity reaches 300 fT/Hz1/2. We systematically study the dependence of the magnetometer performance on the optical duty cycles of the pump light and find that better performance is achieved with shorter duty cycles, with the highest values measured at 1.25% duty cycle.