Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Applied Physics

Study of wall coatings for vapor-cell laser traps

Michelle S. Stephens, R. Rhodes, Carl Wieman

Published Sep 15, 1994• 94 citations
Publisher

Abstract

Efficient collection of atoms into a vapor-cell laser trap requires a special wall material for the cell that minimizes the interactions between the vapor and the wall. Tests of several different wall coatings and materials are reported, and measurements of adsorption energies, outgassing, and chemical reaction rates between the alkali vapor and the walls are described. It is demonstrated that each of these parameters affects the collection efficiency.

DOI
10.1063/1.358502

Related papers

High collection efficiency in a laser trap

Michelle S. Stephens, Carl Wieman

We present the results of the first study of the fundamental processes governing collection efficiency of neutral atoms in a vapor cell laser trap. The experimental test of our model of the collection process closely agrees with our predictions based on the measured properties of the laser beams and cell. This study has led to the development of special vapor cell wall coatings. We have demonstrated a collection efficiency of 6% for cesium and predict more than 50% could be achieved under optimum conditions. This work develops the concepts for and demonstrates the feasibility of new experiments using short-lived radioactive isotopes.

Physical Review Letters•Jun 13, 1994•31 citations

Optimizing the capture process in optical traps

Michelle S. Stephens, K. Lindquist, Carl Wieman

We present techniques for the most efficient capture of atoms in a modified vaporcell magneto-optical trap. We explain how changing the size and power of the trapping beams affects the capture rate of the trap. We calculate the requirement of wall coatings designed to minimize the interaction of an alkali vapor with the wall and explain how this affects trapping efficiency. Finally, we present measurements of the performance of a “Dryfilm” coated cell.

WORLD SCIENTIFIC eBooks•Jan 1, 2008•0 citations

Efficient Capture in a vapor cell magneto-optical trap

Michelle S. Stephens, Royal Rhodes, Carl Wieman

Laser cooling and trapping of rare, radioactive isotopes has the potential for greatly enhancing experiments in high resolution spectroscopy of exotic species, electron electric-dipole moment searches, β-decay asymmetry, and parity nonconservation. The ability to hold atoms for several seconds at high densities (1011 cm-3) and away from the perturbing effects of the cell walls makes laser cooling and trapping attractive for use in the experiments mentioned above. Because many isotopes of interest for these experiments are difficult to produce, the ability to quickly and efficiently collect these atoms from a dilute vapor is crucial. We have demonstrated a 6% collection efficiency in a special wall-coated cell. We have developed a model that predicts the capture efficiency as a function of trap properties and have developed techniques for measuring the pertinent characteristics.

•May 8, 1994•0 citations

Method for characterizing self-assembled monolayers as antirelaxation wall coatings for alkali vapor cells

Youngwoo Yi, H. G. Robinson, Svenja A. Knappe +5 more

We describe a method for characterizing self-assembled monolayers (SAMs) in terms of their performance as antirelaxation wall coatings for alkali atom vapor cells. A combination of initial surface analysis and subsequent laser spectroscopy is used to provide insight into the quality of the coating, as well as its performance under the exposure to alkalis as it occurs, for example, when used in applications such as atomic magnetometers or clocks. Fused silica plates coated with octadecyltrichlorosilane SAMs were used to make cubic R87b gas cells. The surface was characterized by x-ray diffraction, contact angle measurements, and atomic force microscopy. Measurements of hyperfine resonance linewidths and frequency shifts show that the rubidium vapor atoms collide up to 40 times with the walls of the cells before their coherence relaxes and their adsorption energy is around 0.065 eV. Chemical analysis of the cell indicates some weak reactions between the coating and the rubidium atoms.

Journal of Applied Physics•Jul 15, 2008•77 citations

Efficient collection of atoms by ysing optical trapping in a coated-wall vapor cell

Michelle S. Stephens, K. G. Lindquist, Carl Wieman

Quantum Electronics and Laser Science Conference•May 2, 1993•0 citations

Optimizing capture efficiency in a magneto-optical trap

Michelle S. Stephens, Carl Wieman, Kristan L. Corwin +3 more

We have studied the user of vapor-cell magneto-optical traps for the collection and investigation of trace elements of radioactive isotopes. The fundamental processes governing efficient collection of neutral isotopes in a trap have been identified and integrated into a model that accurately describes the collection process. The model has been verified experimentally; a 6% capture efficiency has been demonstrated for stable Cs isotopes and we predict a simple change in trapping cell geometry will allow a 50% capture efficiency. This paper discussed the issues involved in efficient capture, such as the trapping laser properties and wall-coatings. It describes a new cell design for efficient capture and discusses current work towards trapping small numbers of 221Fr (T1/2 equals 4.8 minutes) atoms.© (1995) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 7, 1995•0 citations
Efficient collection of atoms into a vapor-cell laser trap requires a special wall material for the cell that minimizes the interactions between the vapor and the wall. Tests of several different wall coatings and materials are reported, and measurements of adsorption energies, outgassing, and chemical reaction rates between the alkali vapor and the walls are described. It is demonstrated that each of these parameters affects the collection efficiency.
We present the results of the first study of the fundamental processes governing collection efficiency of neutral atoms in a vapor cell laser trap. The experimental test of our model of the collection process closely agrees with our predictions based on the measured properties of the laser beams and cell. This study has led to the development of special vapor cell wall coatings. We have demonstrated a collection efficiency of 6% for cesium and predict more than 50% could be achieved under optimum conditions. This work develops the concepts for and demonstrates the feasibility of new experiments using short-lived radioactive isotopes.
Laser cooling and trapping of rare, radioactive isotopes has the potential for greatly enhancing experiments in high resolution spectroscopy of exotic species, electron electric-dipole moment searches, β-decay asymmetry, and parity nonconservation. The ability to hold atoms for several seconds at high densities (1011 cm-3) and away from the perturbing effects of the cell walls makes laser cooling and trapping attractive for use in the experiments mentioned above. Because many isotopes of interest for these experiments are difficult to produce, the ability to quickly and efficiently collect these atoms from a dilute vapor is crucial. We have demonstrated a 6% collection efficiency in a special wall-coated cell. We have developed a model that predicts the capture efficiency as a function of trap properties and have developed techniques for measuring the pertinent characteristics.
We describe a method for characterizing self-assembled monolayers (SAMs) in terms of their performance as antirelaxation wall coatings for alkali atom vapor cells. A combination of initial surface analysis and subsequent laser spectroscopy is used to provide insight into the quality of the coating, as well as its performance under the exposure to alkalis as it occurs, for example, when used in applications such as atomic magnetometers or clocks. Fused silica plates coated with octadecyltrichlorosilane SAMs were used to make cubic R87b gas cells. The surface was characterized by x-ray diffraction, contact angle measurements, and atomic force microscopy. Measurements of hyperfine resonance linewidths and frequency shifts show that the rubidium vapor atoms collide up to 40 times with the walls of the cells before their coherence relaxes and their adsorption energy is around 0.065 eV. Chemical analysis of the cell indicates some weak reactions between the coating and the rubidium atoms.
We have studied the user of vapor-cell magneto-optical traps for the collection and investigation of trace elements of radioactive isotopes. The fundamental processes governing efficient collection of neutral isotopes in a trap have been identified and integrated into a model that accurately describes the collection process. The model has been verified experimentally; a 6% capture efficiency has been demonstrated for stable Cs isotopes and we predict a simple change in trapping cell geometry will allow a 50% capture efficiency. This paper discussed the issues involved in efficient capture, such as the trapping laser properties and wall-coatings. It describes a new cell design for efficient capture and discusses current work towards trapping small numbers of 221Fr (T1/2 equals 4.8 minutes) atoms.© (1995) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.