Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Modern Optics

Precision Measurement of the2

A.S. Bell, Patrick Robert Gill, H. Arthur Klein, Andrew P. Levick, W. R. C. Rowley

Published Feb 1, 1992• 39 citations
Publisher

Abstract

The 4f13 6s2 2F7/2–4f14 5d 2D5/2 3·43 μm infrared transition in 172Yb+ has been driven for the first time and measured to be 87 360 087(4) MHz. The frequency was determined by probing a cloud of 172Yb+ ions held in a radiofrequency trap in the presence of helium buffer gas. The infrared radiation was generated by difference frequency mixing in LiNbO3. The frequency measurement is part of a programme to locate the 4f14 6s 2S1/2–4f13 6s2 2F7/2 467 nm ultra-narrow transition in laser-cooled Yb+.

DOI
10.1080/09500349214550371

Related papers

Measurement of the 2 S1/2 −2 D5/2 411-nm interval in laser-cooled trapped Yb+172 ions

Patrick Robert Gill, Hugh A. Klein, Andrew P. Levick +3 more

The 4${\mathit{f}}^{14}$6s${\mathrm{}}^{2}$${\mathit{S}}_{1/2}$--4${\mathit{f}}^{14}$5d${\mathrm{}}^{2}$${\mathit{D}}_{5/2}$ 411-nm transition in $^{172}\mathrm{Yb}^{+}$ has been measured to be 729 476 868(11) MHz. The frequency was determined by probing a cold cloud of a few $^{172}\mathrm{Yb}^{+}$ ions held in a radio-frequency trap. The frequency measurement is part of a program to locate the 4${\mathit{f}}^{14}$6s${\mathrm{}}^{2}$${\mathit{S}}_{1/2}$--4${\mathit{f}}^{13}$6${\mathit{s}}^{2}$${\mathrm{}}^{2}$${\mathit{F}}_{7/2}$ 467-nm ultranarrow transition in laser-cooled ${\mathrm{Yb}}^{+}$. The 4${\mathit{f}}^{13}$6${\mathit{s}}^{2}$${\mathrm{}}^{2}$${\mathit{F}}_{7/2}$--4${\mathit{f}}^{13}$5d6s${\mathrm{}}^{1}$D[K= 5/2${]}_{\mathit{J}=5/2}$ transition at 638 nm has been driven in order to depopulate the 4${\mathit{f}}^{13}$6${\mathit{s}}^{2}$${\mathrm{}}^{2}$${\mathit{F}}_{7/2}$ state.

Physical Review A•Aug 1, 1995•23 citations

An optical frequency standard based on the 2 S 1/2 — 2 F 7/2 transition in 171 Yb +

Stephen A. Webster, A. F. B. Stannard, Kazumoto Hosaka +1 more

The 2S1/2 (F = 0) - 2F7/2 (F = 3, m F = 0) transition at 467 nm in a single, trapped, laser cooled ion of 171Yb+ has the potential to be an extremely accurate optical frequency reference. Systematic shifts have been evaluated and are currently dominated by the ac-Stark shift. However, this is not expected to be the case as probe laser linewidth is reduced. A heterodyne measurement of the probe laser shows it to have a width of 20 Hz on a 1 minute timescale. The atomic spectrum on the other hand, has been found to have a broadened width of 200 Hz. Using heterodyne detection of light reflected from the trap electrodes, Doppler shifting due to vibration of the trap is identified as the additional source of broadening.

European Frequency and Time Forum•Jan 1, 2006•0 citations

Precision frequency measurement of the 2S1/2 — 2F7/2 electric octupole transition in a single 171Yb+ ion

Stephen A. Webster, Kazumoto Hosaka, Barney Walton +2 more

We report precision laser spectroscopy of the2S1/2(F = 0, mF=0)-2F7/2(F =3, mF= 0) clock transition in a single, trapped, laser cooled ion of171Yb+. The absolute frequency is measured to be 642 121 496 772 656 (12) Hz, a factor of 20 more accurate than previous measurements.

Conference on Precision Electromagnetic Measurements•Jun 1, 2008•5 citations

SPECTROSCOPY AND PRECISION FREQUENCY MEASUREMENT OF THE 435.5 nm CLOCK TRANSITION OF 171 Yb +

Chr. Tamm, T. Schneider, E. Peik

We describe experimental investigations on an optical frequency standard based on a single laser cooled 171 Yb + ion confined in a radiofrequency Paul trap. The electric-quadrupole transition from the 2 S 1/2 ( F = 0) ground state to the 2 D 3/2 ( F = 2) state is used as the reference transition. Its wavelength is 435.5 nm and its natural linewidth is 3.1 Hz. The transition is probed using a diode laser system whose short-term frequency stability is derived from an environmentally isolated ULE cavity. The transition is resolved with a Fourier-limited full halfwidth of approximately 30 Hz. The absolute optical transition frequency was determined using a femtosecond frequency comb generator and a Cs fountain clock as the frequency reference. The measured frequency value is 688 358 979 309 312 Hz at an ambient blackbody radiation field of 300 K. The 1σ fractional uncertainty of this frequency measurement is 1 · 10 -14 .

Symposium on Frequency Standards and Metrology•May 1, 2002•3 citations

Optical frequency standard based on a trapped171Yb+ion

Chr. Tamm, T. Schneider, E. Peik

We describe experimental investigations on an optical frequency standard based on a single laser cooled 171Yb+ ion confined in a radiofrequency Paul trap. The 435.5 nm electric-quadrupole transition from the 2S1/2(F=0) groudn state to the 2D3/2(F=2) state is probed using a diode laser system whose short-term frequency stability is derived from an environmentally isolated ULE cavity. The transition is resolved with a Foruier-limited full halfwidth of approximately 30 Hz. The absolute optical transition frequency is determined using a femtosecond frequency comb generator and a Cs fountain clock as the frequency reference. The measured frequency value is 688 358 979 321 Hz at an ambient blackbody radiation field of 300 K. The 1σ fractional uncertainty of this frequency measurement is 1×10-14.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Oct 8, 2003•0 citations

Prospect for Precision Measurement of the Yb2+ 1S0–\(^{3}\text{P}_{0}^{o}\) Transition Frequency

Naoki Kimura, Masatoshi Kajita

We discuss prospects of precision measurement of the Yb2+ 4f14 1S0–4f13 5d \(^{3}\text{P}_{0}^{o}\) transition frequency (1.4 × 1015 Hz). Attainable uncertainty of this precision measurement is theoretically estimated. This transition is free from the electric quadrupole shift, and this specific property allows for precision spectroscopy using a multi-ion string Coulomb crystal and contributes to reduction of the statistical uncertainty. A systematic uncertainty of the order 10−18 is attainable because the Stark and Zeeman shifts are small due to the intrinsic level structure of multiply charged ions. This clock transition can be monitored without quantum logical methods by observing the laser-induced fluorescence from the 1S0–\(^{3}\text{P}_{1}^{o}\) transition with a closed optical cycle.

Journal of the Physical Society of Japan•May 31, 2021•2 citations
The 4f13 6s2 2F7/2–4f14 5d 2D5/2 3·43 μm infrared transition in 172Yb+ has been driven for the first time and measured to be 87 360 087(4) MHz. The frequency was determined by probing a cloud of 172Yb+ ions held in a radiofrequency trap in the presence of helium buffer gas. The infrared radiation was generated by difference frequency mixing in LiNbO3. The frequency measurement is part of a programme to locate the 4f14 6s 2S1/2–4f13 6s2 2F7/2 467 nm ultra-narrow transition in laser-cooled Yb+.
The 4${\mathit{f}}^{14}6s6s6s{\mathrm{}}^{2}$${\mathit{S}}_{1/2}$--4${\mathit{f}}^{14}$5d${\mathrm{}}^{2}$${\mathit{D}}_{5/2}$ 411-nm transition in 172Yb+^{172}\mathrm{Yb}^{+}172Yb+ has been measured to be 729 476 868(11) MHz. The frequency was determined by probing a cold cloud of a few 172Yb+^{172}\mathrm{Yb}^{+}172Yb+ ions held in a radio-frequency trap. The frequency measurement is part of a program to locate the 4${\mathit{f}}^{14}6s6s6s{\mathrm{}}^{2}$${\mathit{S}}_{1/2}$--4${\mathit{f}}^{13}$6${\mathit{s}}^{2}$${\mathrm{}}^{2}$${\mathit{F}}_{7/2}$ 467-nm ultranarrow transition in laser-cooled ${\mathrm{Yb}}^{+}$. The 4${\mathit{f}}^{13}$6${\mathit{s}}^{2}$${\mathrm{}}^{2}$${\mathit{F}}_{7/2}$--4${\mathit{f}}^{13}$5d6s${\mathrm{}}^{1}$D[K= 5/2${]}_{\mathit{J}=5/2}$ transition at 638 nm has been driven in order to depopulate the 4${\mathit{f}}^{13}$6${\mathit{s}}^{2}$${\mathrm{}}^{2}$F7/2{\mathit{F}}_{7/2}F7/2​ state.
The 2S1/2 (F = 0) - 2F7/2 (F = 3, m F = 0) transition at 467 nm in a single, trapped, laser cooled ion of 171Yb+ has the potential to be an extremely accurate optical frequency reference. Systematic shifts have been evaluated and are currently dominated by the ac-Stark shift. However, this is not expected to be the case as probe laser linewidth is reduced. A heterodyne measurement of the probe laser shows it to have a width of 20 Hz on a 1 minute timescale. The atomic spectrum on the other hand, has been found to have a broadened width of 200 Hz. Using heterodyne detection of light reflected from the trap electrodes, Doppler shifting due to vibration of the trap is identified as the additional source of broadening.
We describe experimental investigations on an optical frequency standard based on a single laser cooled 171 Yb + ion confined in a radiofrequency Paul trap. The electric-quadrupole transition from the 2 S 1/2 ( F = 0) ground state to the 2 D 3/2 ( F = 2) state is used as the reference transition. Its wavelength is 435.5 nm and its natural linewidth is 3.1 Hz. The transition is probed using a diode laser system whose short-term frequency stability is derived from an environmentally isolated ULE cavity. The transition is resolved with a Fourier-limited full halfwidth of approximately 30 Hz. The absolute optical transition frequency was determined using a femtosecond frequency comb generator and a Cs fountain clock as the frequency reference. The measured frequency value is 688 358 979 309 312 Hz at an ambient blackbody radiation field of 300 K. The 1σ fractional uncertainty of this frequency measurement is 1 · 10 -14 .
We describe experimental investigations on an optical frequency standard based on a single laser cooled 171Yb+ ion confined in a radiofrequency Paul trap. The 435.5 nm electric-quadrupole transition from the 2S1/2(F=0) groudn state to the 2D3/2(F=2) state is probed using a diode laser system whose short-term frequency stability is derived from an environmentally isolated ULE cavity. The transition is resolved with a Foruier-limited full halfwidth of approximately 30 Hz. The absolute optical transition frequency is determined using a femtosecond frequency comb generator and a Cs fountain clock as the frequency reference. The measured frequency value is 688 358 979 321 Hz at an ambient blackbody radiation field of 300 K. The 1σ fractional uncertainty of this frequency measurement is 1×10-14.
Prospect for Precision Measurement of the Yb2+ 1S0–3P0o^{3}\text{P}_{0}^{o}3P0o​ Transition Frequency
We discuss prospects of precision measurement of the Yb2+ 4f14 1S0–4f13 5d 3P0o^{3}\text{P}_{0}^{o}3P0o​ transition frequency (1.4 × 1015 Hz). Attainable uncertainty of this precision measurement is theoretically estimated. This transition is free from the electric quadrupole shift, and this specific property allows for precision spectroscopy using a multi-ion string Coulomb crystal and contributes to reduction of the statistical uncertainty. A systematic uncertainty of the order 10−18 is attainable because the Stark and Zeeman shifts are small due to the intrinsic level structure of multiply charged ions. This clock transition can be monitored without quantum logical methods by observing the laser-induced fluorescence from the 1S0–3P1o^{3}\text{P}_{1}^{o}3P1o​ transition with a closed optical cycle.