Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Measurement and characterization of the three-dimensional coherence function in neutron interferometry

H. Rauch, H. Wölwitsch, Helmut Kaiser, R. Clothier, S. Werner

Published Feb 1, 1996• 67 citations
Publisher

Abstract

The spatial coherence function in all three orthogonal directions has been measured by means of perfect crystal neutron interferometry. It has been demonstrated that the coherence function is given by the Fourier transform of the related momentum distribution, which in turn is determined by the collimation and monochromatization of the beam incident upon and traversing the interferometer. Thus, a measurement of the coherence function can replace a measurement of the momentum distribution in certain cases. Retrieval of the coherence can be accomplished by phase echo and/or postselection methods. A complete retrieval of the coherence is impossible in principle due to unavoidable loss factors.

DOI
10.1103/physreva.53.902

Related papers

Neutron interferometers and apparatus

Helmut Rauch, Samuel A. Werner

Abstract Among the various areas of neutron optical research, neutron interferometry has provided some of the most challenging and spectacular developments. In most cases, separated coherent beams are used which are produced either by wavefront division (Young’s type) or by amplitude division (Mach− Zehnder type). These beams are subsequently coherently superposed after passing through regions of space where the neutron wavefunction is modified in phase and amplitude by various interactions: nuclear, magnetic, electromagnetic, gravitational, or by geometry and topology (as in Aharonov−Bohm-type experiments). Various types of neutron interferometers that have been tested are shown in Fig. 2.1. The first neutron interferometer was based upon wavefront division and biprism deflection, but it had several constraints for interferometric applications mainly due to the small beam separation (100 μm) (Maier-Leibnitz and Springer 1962). Nevertheless, this method gained further interest for diffraction experiments from macroscopic objects and for the detection of weak interaction effects where the long flight paths (10 m) enhance the sensitivity for the measurements of these effects (Gähler et al. 1980; Klein et al. 1981a). The perfect-crystal interferometer (Rauch et al. 1974) provides widely separated coherent beams and has become a standard method for advanced neutron optical investigations. The development of diffraction and phase grating interferometers extended the Mach-Zehnder interferometer method to very slow neutrons (loffe et al. 1985; Gruber et al. 1989). The superposition of spin-up and spin-down states in the longitudinal direction provides the basis for Larmor and Ramsey interferometry, where no lateral beam splitting is necessary. The well-known spin-echo systems (Mezei 1972) and zero-field spin-echo systems (Gähler and Golub 1987; Dubbers et al. 1989) are examples of such interferometers, which also play an important role in atom interferometry (Bord é 1989; Kasevich and Chu 1991; Riehle et al. 1991).

Oxford University Press eBooks•Aug 10, 2000•0 citations

Coherence and spectral filtering in neutron interferometry

Helmut Kaiser, R. Clothier, S. A. Werner +2 more

The coherence length of a neutron wave packet depends on the spectral width of the distribution of wave vectors that make up the packet. The coherent overlap of the wave packets traversing the two beam paths in a perfect-silicon-crystal neutron interferometer (NI) is altered by placing a material with a neutron-nuclear optical potential in one of the beam paths in the NI. If the optical potential is positive, it causes a delay of the wave packet and a loss of fringe visibility. By use of an analyzer crystal, we narrow the spectral distribution after the mixing and interference has occurred in the last crystal slab of the NI. This increases the coherence length and restores some of the fringe visibility.

Physical Review A•Jan 1, 1992•66 citations

Measurements of the Vertical Coherence Length in Neutron Interferometry

Dmitry A. Pushin, M. Arif, M. G. Huber +1 more

The study and use of macroscopic quantum coherence requires long coherence lengths. Here we describe an approach to measuring the vertical coherence length in neutron interferometry, along with improvements to the NIST interferometer that led to a measured coherence length of 790 A. The measurement is based on introducing a path separation and measuring the loss in contrast as this separation is increased. The measured coherence length is consistent with the momentum distribution of the neutron beam. Finally, we demonstrate that the loss in contrast with beam displacement in one leg of the interferometer can be recovered by introducing a corresponding displacement in the second leg.

Physical Review Letters•Jun 26, 2008•32 citations

Coherent control of neutron interferometry

Dmitry A. Pushin

In this thesis, several novel techniques are proposed and demonstrated for measuring the coherent properties of materials and testing aspects of quantum information processing using a single crystal neutron interferometer. In particular we introduce methods for reciprocal space encoding of spatial information systematically in a neutron interferometer. First, a proof of principle experiment is conducted for coherent reciprocal space neutron imaging. This newly proposed technique overcomes the limitation of spacial resolution of current two dimensional neutron detectors. Second, an experiment to measure the vertical coherent length of a neutron interferometer is reported, which extends the previously achieved path separation. Third, we propose a new interferometry geometry that reduces the sensitivity of the neutron interferometer to environmental vibrational disturbances. The method is based on a quantum error compensating algorithm. Finally, a new method that is capable of measuring the autocorrelation function of a sample is proposed. This new technique can extend the capability of traditional neutron scattering experiments. All experiments are conducted at the neutron interferometry facility at the National Institute of Standards and Technology (NIST).

•Jan 1, 2006•4 citations

Test of Quantum Mechanics by Matter Wave Interferometry

Helmut Rauch

The capability of neutron interferometry for the testing of quantum mechanical predictions on a macroscopic scale is discussed. Within a proper shaped monolithic perfect silicon crystal two widely separated coherent beams of monochromatic thermal neutrons are produced, which can be influenced individually by means of scalar as well as magnetic phase shifts and by static and time-dependent spin rotations. Only self-interference appears in the neutron case but the interference pattern shows influences of the collective properties of the whole ensemble of neutrons of the beam too. The following measurements are discussed in view of their relation to quantum mechanics: coherence measurements, 4π-symmetry of spinors, spin superposition and coherent energy transfer measurements.

Advanced series in applied physics•Jan 1, 1997•1 citation

Quantum Phenomena Studied by Neutron Interferometry

Helmut Rauch

Neutrons are proper tools for testing quantum mechanics because they are massive, they couple to electromagnetic fields due to their magnetic moment and they are subject to all basic interactions and they are sensitive to topological effects, as well. Related experiments will be discussed. Recent neutron interferometry experiments based on postselection methods renewed the discussion about quantum nonlocality and the quantum measuring process. It has been shown that interference phenomena can be revived even when the overall interference pattern has lost its contrast. This indicates a persisting coupling in phase space even in cases of spatially separated Schrödinger Cat-like situations. These states are extremely fragile and sensitive against any kind of fluctuations and other decoherence processes. More complete quantum experiments also show that a complete retrieval of quantum states behind an interaction volume becomes impossible in principle.

Physica Scripta•Jan 1, 1998•8 citations
The spatial coherence function in all three orthogonal directions has been measured by means of perfect crystal neutron interferometry. It has been demonstrated that the coherence function is given by the Fourier transform of the related momentum distribution, which in turn is determined by the collimation and monochromatization of the beam incident upon and traversing the interferometer. Thus, a measurement of the coherence function can replace a measurement of the momentum distribution in certain cases. Retrieval of the coherence can be accomplished by phase echo and/or postselection methods. A complete retrieval of the coherence is impossible in principle due to unavoidable loss factors.
Abstract Among the various areas of neutron optical research, neutron interferometry has provided some of the most challenging and spectacular developments. In most cases, separated coherent beams are used which are produced either by wavefront division (Young’s type) or by amplitude division (Mach− Zehnder type). These beams are subsequently coherently superposed after passing through regions of space where the neutron wavefunction is modified in phase and amplitude by various interactions: nuclear, magnetic, electromagnetic, gravitational, or by geometry and topology (as in Aharonov−Bohm-type experiments). Various types of neutron interferometers that have been tested are shown in Fig. 2.1. The first neutron interferometer was based upon wavefront division and biprism deflection, but it had several constraints for interferometric applications mainly due to the small beam separation (100 μm) (Maier-Leibnitz and Springer 1962). Nevertheless, this method gained further interest for diffraction experiments from macroscopic objects and for the detection of weak interaction effects where the long flight paths (10 m) enhance the sensitivity for the measurements of these effects (Gähler et al. 1980; Klein et al. 1981a). The perfect-crystal interferometer (Rauch et al. 1974) provides widely separated coherent beams and has become a standard method for advanced neutron optical investigations. The development of diffraction and phase grating interferometers extended the Mach-Zehnder interferometer method to very slow neutrons (loffe et al. 1985; Gruber et al. 1989). The superposition of spin-up and spin-down states in the longitudinal direction provides the basis for Larmor and Ramsey interferometry, where no lateral beam splitting is necessary. The well-known spin-echo systems (Mezei 1972) and zero-field spin-echo systems (Gähler and Golub 1987; Dubbers et al. 1989) are examples of such interferometers, which also play an important role in atom interferometry (Bord é 1989; Kasevich and Chu 1991; Riehle et al. 1991).
The coherence length of a neutron wave packet depends on the spectral width of the distribution of wave vectors that make up the packet. The coherent overlap of the wave packets traversing the two beam paths in a perfect-silicon-crystal neutron interferometer (NI) is altered by placing a material with a neutron-nuclear optical potential in one of the beam paths in the NI. If the optical potential is positive, it causes a delay of the wave packet and a loss of fringe visibility. By use of an analyzer crystal, we narrow the spectral distribution after the mixing and interference has occurred in the last crystal slab of the NI. This increases the coherence length and restores some of the fringe visibility.
The study and use of macroscopic quantum coherence requires long coherence lengths. Here we describe an approach to measuring the vertical coherence length in neutron interferometry, along with improvements to the NIST interferometer that led to a measured coherence length of 790 A. The measurement is based on introducing a path separation and measuring the loss in contrast as this separation is increased. The measured coherence length is consistent with the momentum distribution of the neutron beam. Finally, we demonstrate that the loss in contrast with beam displacement in one leg of the interferometer can be recovered by introducing a corresponding displacement in the second leg.
In this thesis, several novel techniques are proposed and demonstrated for measuring the coherent properties of materials and testing aspects of quantum information processing using a single crystal neutron interferometer. In particular we introduce methods for reciprocal space encoding of spatial information systematically in a neutron interferometer. First, a proof of principle experiment is conducted for coherent reciprocal space neutron imaging. This newly proposed technique overcomes the limitation of spacial resolution of current two dimensional neutron detectors. Second, an experiment to measure the vertical coherent length of a neutron interferometer is reported, which extends the previously achieved path separation. Third, we propose a new interferometry geometry that reduces the sensitivity of the neutron interferometer to environmental vibrational disturbances. The method is based on a quantum error compensating algorithm. Finally, a new method that is capable of measuring the autocorrelation function of a sample is proposed. This new technique can extend the capability of traditional neutron scattering experiments. All experiments are conducted at the neutron interferometry facility at the National Institute of Standards and Technology (NIST).
The capability of neutron interferometry for the testing of quantum mechanical predictions on a macroscopic scale is discussed. Within a proper shaped monolithic perfect silicon crystal two widely separated coherent beams of monochromatic thermal neutrons are produced, which can be influenced individually by means of scalar as well as magnetic phase shifts and by static and time-dependent spin rotations. Only self-interference appears in the neutron case but the interference pattern shows influences of the collective properties of the whole ensemble of neutrons of the beam too. The following measurements are discussed in view of their relation to quantum mechanics: coherence measurements, 4π-symmetry of spinors, spin superposition and coherent energy transfer measurements.
Neutrons are proper tools for testing quantum mechanics because they are massive, they couple to electromagnetic fields due to their magnetic moment and they are subject to all basic interactions and they are sensitive to topological effects, as well. Related experiments will be discussed. Recent neutron interferometry experiments based on postselection methods renewed the discussion about quantum nonlocality and the quantum measuring process. It has been shown that interference phenomena can be revived even when the overall interference pattern has lost its contrast. This indicates a persisting coupling in phase space even in cases of spatially separated Schrödinger Cat-like situations. These states are extremely fragile and sensitive against any kind of fluctuations and other decoherence processes. More complete quantum experiments also show that a complete retrieval of quantum states behind an interaction volume becomes impossible in principle.