Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)

Absolute frequency measurement of 115 In + clock transition

Y. H. Wang, T. Liu, Rainer Dumke, Alois Stejskal, Yanning Zhao, Jiongyang Zhang, Z. H. Lu, L. J. Wang, Th. Becker, HERBERT WALTHER

Published Jun 1, 2007• 0 citations
Publisher

Abstract

We report recent improvement in absolute frequency measurement of the115In+5s21S0-5s5p3P0clock transition at 236.5 nm. Using a narrowline laser as a local oscillator, a linewidth of 43 Hz for the transition is resolved. The uncertainty of the transition frequency's centroid is 18 Hz, leading to a fractional uncertainty of 1.4 x 10-14. In the experiment, a single115In+is trapped in a three-ring Paul-Straubel trap and laser cooled to the trap's vibrational ground states.

DOI
10.1109/cleoe-iqec.2007.4386817

Related papers

Improved absolute frequency measurement of the 115In+ 5s 2 1 S 0-5s5p 3 P 0 narrowline transition: Progress towards an optical frequency standard

Y. H. Wang, Tao Liu, Rainer Dumke +7 more

We report on an improved absolute frequency measurement of the 5s 2 1 S 00-5s5p 3 P 0 narrowline clock transition at 236.5 nm, for a single, trapped, and laser-cooled 115In ion. Using a narrowline laser as the local oscillator, a linewidth of 43 Hz for the transition is resolved. The uncertainty of the transition frequency’s centroid is 18 Hz, leading to a fractional uncertainty of 1.4 × 10−14. For absolute frequency measurement, we use an optical frequency comb locked to a cesium clock as the reference. The transition frequency is found to be 1267402452900967(63) Hz, averaged over 13 days of separate measurements. The accuracy is about 5.0 × 10−14. We discuss possibilities for further improvement.

Laser Physics•Jul 1, 2007•9 citations

SPECTROSCOPY AND PRECISION FREQUENCY MEASUREMENT OF THE 435.5 nm CLOCK TRANSITION OF 171 Yb +

Chr. Tamm, T. Schneider, E. Peik

We describe experimental investigations on an optical frequency standard based on a single laser cooled 171 Yb + ion confined in a radiofrequency Paul trap. The electric-quadrupole transition from the 2 S 1/2 ( F = 0) ground state to the 2 D 3/2 ( F = 2) state is used as the reference transition. Its wavelength is 435.5 nm and its natural linewidth is 3.1 Hz. The transition is probed using a diode laser system whose short-term frequency stability is derived from an environmentally isolated ULE cavity. The transition is resolved with a Fourier-limited full halfwidth of approximately 30 Hz. The absolute optical transition frequency was determined using a femtosecond frequency comb generator and a Cs fountain clock as the frequency reference. The measured frequency value is 688 358 979 309 312 Hz at an ambient blackbody radiation field of 300 K. The 1σ fractional uncertainty of this frequency measurement is 1 · 10 -14 .

Symposium on Frequency Standards and Metrology•May 1, 2002•3 citations

Progress Toward an Optical Frequency Standard Based on a Single Indium Ion

Y. H. Wang, T. Liu, Alois Stejskal +7 more

We report on the current status of the optical frequency standard based on a single 115In+ ion. A single Indium ion is being trapped in a Paul-Strauble type trap and cooled in combination of Doppler cooling and sideband cooling to its lowest vibrational states. To interrogate the1S0-3P0clock transition with high accuracy we demonstrate a Hz-level laser system resonant to this transition. With the current setup we are able to achieve a measured linewidth of the clock transition of 260 Hz. The statistical uncertainty of the absolute frequency measurement is 3×10-13, limited mainly by our reference frequency standard.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jun 1, 2006•6 citations

Indium single-ion optical frequency standard

Thomas P. Becker, M. Eichenseer, Alexander Yu. Nevsky +5 more

Single laser-cooled ions in radiofrequency traps can serve as the basis for highly stable optical frequency standards. Here we present recent results on In+, using the 1S0 yields 3P0 line at 236.5 nm wavelength as the clock transition. This resonance has a natural linewidth of only 0.82 Hz and systematic shifts should be controllable at the mHz level. A single indium ion is stored in a miniature Paul- Straubel trap and laser cooled to a temperature of about 100 (mu) K. The clock transition is excited using a frequency quadrupled 946 nm Nd:YAG laser. A fractional resolution of 1.3 (DOT) 10-13 has been achieved so far (linewidth of 170 Hz at 1267 THz). The absolute optical frequency of the clock transition has been measured with an uncertainty being less than 3 (DOT) 10-13 using a frequency chain and a methane-stabilized HeNe laser that was calibrated with a cesium clock.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 3, 2001•0 citations

Indium single ion optical frequency standard

T. Becker, M. Eichenseer, Alexander Yu. Nevsky +5 more

A single laser cooled ion in a radiofrequency trap can serve as the basis for a highly stable optical frequency standard. We present recent results of our work on single indium ions, using the /sup 1/S/sub 0/ to /sup 3/P/sub 0/ transition at 236.5 nm wave-length as the clock transition. This resonance has a linewidth of only 0.82 Hz where systematic shifts should be controllable on the mHz level. A single In/sup +/ ion is stored in a miniature Paul-Straubel trap and laser cooled to a temperature of about 100 /spl mu/K. The clock transition is excited using a frequency quadrupled Nd:YAG laser. A fractional resolution of 1.3/spl middot/10/sup -13/ has been achieved so far (linewidth of 170 Hz at 1267 THz). The absolute frequency of the clock transition clock transition has been measured with an uncertainty of 2/spl middot/10/sup -13/ using a frequency chain and a methane-stabilized HeNe laser as a reference, that was calibrated with a cesium clock.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Nov 13, 2002•3 citations

Hertz-level measurement of the 40 Ca + 4s 2S1/2 – 3d 2D5/2 clock transition frequency with respect to the SI second through the Global Positioning System

Yao Huang, Jian Zhong Cao, P. Liu +6 more

We have measured the absolute frequency of a clock transition at the 10${}^{\ensuremath{-}15}$ level with a single, trapped, laser-cooled ${}^{40}$Ca${}^{+}$ ion in a miniature Paul trap. In our measurement, an optical frequency comb is referenced to a hydrogen maser, which is calibrated to the SI second through the Global Positioning System (GPS). By analyzing the experimental data obtained within 32 days of a total averaging time $>$2 $\ifmmode\times\else\texttimes\fi{}$ 10${}^{6}$ s, the absolute frequency of the ${}^{40}$Ca${}^{+}$ 4$s$ ${}^{2}\phantom{\rule{-0.16em}{0ex}}{S}_{1/2}$--3$d$ ${}^{2}\phantom{\rule{-0.16em}{0ex}}{D}_{5/2}$ clock transition is measured as 411 042 129 776 393.0 (1.6) Hz with a fractional uncertainty of 3.9 $\ifmmode\times\else\texttimes\fi{}$ 10${}^{\ensuremath{-}15}$.

arXiv:1111.5174•Physical Review A•Mar 23, 2012•61 citations
We report recent improvement in absolute frequency measurement of the115In+5s21S0-5s5p3P0clock transition at 236.5 nm. Using a narrowline laser as a local oscillator, a linewidth of 43 Hz for the transition is resolved. The uncertainty of the transition frequency's centroid is 18 Hz, leading to a fractional uncertainty of 1.4 x 10-14. In the experiment, a single115In+is trapped in a three-ring Paul-Straubel trap and laser cooled to the trap's vibrational ground states.
We report on an improved absolute frequency measurement of the 5s 2 1 S 00-5s5p 3 P 0 narrowline clock transition at 236.5 nm, for a single, trapped, and laser-cooled 115In ion. Using a narrowline laser as the local oscillator, a linewidth of 43 Hz for the transition is resolved. The uncertainty of the transition frequency’s centroid is 18 Hz, leading to a fractional uncertainty of 1.4 × 10−14. For absolute frequency measurement, we use an optical frequency comb locked to a cesium clock as the reference. The transition frequency is found to be 1267402452900967(63) Hz, averaged over 13 days of separate measurements. The accuracy is about 5.0 × 10−14. We discuss possibilities for further improvement.
We describe experimental investigations on an optical frequency standard based on a single laser cooled 171 Yb + ion confined in a radiofrequency Paul trap. The electric-quadrupole transition from the 2 S 1/2 ( F = 0) ground state to the 2 D 3/2 ( F = 2) state is used as the reference transition. Its wavelength is 435.5 nm and its natural linewidth is 3.1 Hz. The transition is probed using a diode laser system whose short-term frequency stability is derived from an environmentally isolated ULE cavity. The transition is resolved with a Fourier-limited full halfwidth of approximately 30 Hz. The absolute optical transition frequency was determined using a femtosecond frequency comb generator and a Cs fountain clock as the frequency reference. The measured frequency value is 688 358 979 309 312 Hz at an ambient blackbody radiation field of 300 K. The 1σ fractional uncertainty of this frequency measurement is 1 · 10 -14 .
We report on the current status of the optical frequency standard based on a single 115In+ ion. A single Indium ion is being trapped in a Paul-Strauble type trap and cooled in combination of Doppler cooling and sideband cooling to its lowest vibrational states. To interrogate the1S0-3P0clock transition with high accuracy we demonstrate a Hz-level laser system resonant to this transition. With the current setup we are able to achieve a measured linewidth of the clock transition of 260 Hz. The statistical uncertainty of the absolute frequency measurement is 3×10-13, limited mainly by our reference frequency standard.
Single laser-cooled ions in radiofrequency traps can serve as the basis for highly stable optical frequency standards. Here we present recent results on In+, using the 1S0 yields 3P0 line at 236.5 nm wavelength as the clock transition. This resonance has a natural linewidth of only 0.82 Hz and systematic shifts should be controllable at the mHz level. A single indium ion is stored in a miniature Paul- Straubel trap and laser cooled to a temperature of about 100 (mu) K. The clock transition is excited using a frequency quadrupled 946 nm Nd:YAG laser. A fractional resolution of 1.3 (DOT) 10-13 has been achieved so far (linewidth of 170 Hz at 1267 THz). The absolute optical frequency of the clock transition has been measured with an uncertainty being less than 3 (DOT) 10-13 using a frequency chain and a methane-stabilized HeNe laser that was calibrated with a cesium clock.
A single laser cooled ion in a radiofrequency trap can serve as the basis for a highly stable optical frequency standard. We present recent results of our work on single indium ions, using the /sup 1/S/sub 0/ to /sup 3/P/sub 0/ transition at 236.5 nm wave-length as the clock transition. This resonance has a linewidth of only 0.82 Hz where systematic shifts should be controllable on the mHz level. A single In/sup +/ ion is stored in a miniature Paul-Straubel trap and laser cooled to a temperature of about 100 /spl mu/K. The clock transition is excited using a frequency quadrupled Nd:YAG laser. A fractional resolution of 1.3/spl middot/10/sup -13/ has been achieved so far (linewidth of 170 Hz at 1267 THz). The absolute frequency of the clock transition clock transition has been measured with an uncertainty of 2/spl middot/10/sup -13/ using a frequency chain and a methane-stabilized HeNe laser as a reference, that was calibrated with a cesium clock.
We have measured the absolute frequency of a clock transition at the 10${}^{\ensuremath{-}15}$ level with a single, trapped, laser-cooled 40{}^{40}40Ca+{}^{+}+ ion in a miniature Paul trap. In our measurement, an optical frequency comb is referenced to a hydrogen maser, which is calibrated to the SI second through the Global Positioning System (GPS). By analyzing the experimental data obtained within 32 days of a total averaging time $>$2 $\ifmmode\times\else\texttimes\fi{}$ 106{}^{6}6 s, the absolute frequency of the 40{}^{40}40Ca+{}^{+}+ 4sss 2S1/2{}^{2}\phantom{\rule{-0.16em}{0ex}}{S}_{1/2}2S1/2​--3ddd 2D5/2{}^{2}\phantom{\rule{-0.16em}{0ex}}{D}_{5/2}2D5/2​ clock transition is measured as 411 042 129 776 393.0 (1.6) Hz with a fractional uncertainty of 3.9 $\ifmmode\times\else\texttimes\fi{}$ 10${}^{\ensuremath{-}15}$.