Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Japanese Journal of Applied Physics

Trapping Laser Ablated Ca+ Ions in Linear Paul Trap

Y. Hashimoto, Leo Matsuoka, Hiroyuki Osaki, Yu Fukushima, Shuichi Hasegawa

Published Sep 1, 2006• 24 citations
Publisher

Abstract

We have investigated the efficiency of ion trapping in a linear Paul trap. First, we measured the dependence of trapping efficiency on dc and rf voltages using a channel electron multiplier for the direct detection of the electric current of the trapped ions. The most efficient dc and rf voltages were 5.0 and 175 V, respectively. Second, we calculated the trapping efficiency using a simulation code and compared it with the experimental results. We determined that the efficiency of ion trapping decreased monotonically with increasing dc voltage and had an optimum rf voltage. From the numerical calculation, the dependences of trapping efficiency on dc and rf voltages and the initial kinetic energy of ions was derived and the optimum dc and rf voltages and the initial kinetic energy of ions were found to be 0, 210 V, and 1 eV, respectively.

DOI
10.1143/jjap.45.7108

Related papers

Dynamic laser ablation loading of a linear Paul trap

Lin Li, Zi Li, Xia Hua +1 more

Abstract We present a detailed method for accumulating Ca+ ions controllably in a linear Paul trap. The ions are generated by pulsed laser ablation and dynamically loaded into the ion trap by switching the trapping potential on and off. The loaded ions are precooled by buffer gas and then laser-cooled to form Coulomb crystals for verifying quantity. The number of ions is controlled by manipulating the trapping potential of the ion trap, partial pressure of buffer gas and turn-on time of the entrance end cap voltage. With single-pulse laser ablation, the number of trapped ions ranges from tens to ten thousand. The kinetic energy of loaded ions can be selected via the optimal turn-on time of the entrance end cap. Using multiple-pulse laser ablation, the number is further increased and reaches about 4 × 10 4 . The dynamic loading method has wide application for accumulating low-yielding ions via laser ablation in the ion trap.

arXiv:2402.17981•Journal of Physics D Applied Physics•Apr 29, 2024•9 citations

A Single Laser Cooled Trapped 40 Ca + Ion in a Miniature Paul Trap

Shu Hua-Lin, Guan Hua, Huang Xue-Ren +2 more

We have observed the phenomenon of phase transition of a few trapped ions in a miniature Paul trap. Judging from the quantum jump signals, a single laser-cooled trapped Ca + ion has been realized. The ion temperature is estimated to be 22 mK. The result shows that the amplitude of ion micromotion is strongly dependent on the rf voltage.

Chinese Physics Letters•Jun 16, 2005•16 citations

Isotope-selective manipulation of Ca+using laser heating and cooling in a linear Paul trap

Masanori Kitaoka, Shuichi Hasegawa

We report on the isotope-selective manipulation of Ca + using the laser-heating and laser-cooling techniques in a linear Paul trap. Only 40 Ca + was selectively laser-heated using the optical isotope shift and eliminated from the trap while keeping the target isotope in the trap. The elimination process of the dominant isotope 40 Ca + was investigated and 42, 43, 44, 48 Ca + in the natural isotope mixture of Ca + generated by laser ablation were successfully observed by means of applying the appropriate dc voltage on the end-cap electrodes without changing the laser frequencies, the laser powers and the duration of the laser irradiation. This simplified method enables us to efficiently laser-cool the rare isotopes.

Journal of Physics B Atomic Molecular and Optical Physics•Aug 8, 2012•10 citations

Design and Characteristic Measurement of Miniature Three-Segment Linear Paul Trap

T. Furukawa, Jin Nishimura, U. Tanaka +1 more

We have fabricated a miniature three-segment linear Paul trap with r 0=0.6 mm and 2Z 0=4 mm. In order to perform quantum-state manipulation of trapped 40 Ca+ ions, we discuss the required harmonic oscillation frequencies which allow us to perform effective sideband cooling and have measured those that depend on the dimensions of the trap. A laser beam that has a component in the radial direction of the linear trap as well as that propagating along the trap axis has been used to detect the fluorescence spectra of the 42 S 1/2–42 P 1/2 transition. We have observed that the profile of the fluorescence spectrum obtained with the side laser beam is markedly different from that obtained with the axial laser beam due to micromotion. By applying additional DC voltages, the micromotion has been compensated, its amplitude has been estimated, and crystallization has been observed for two 40 Ca+ and four 40 Ca+ ions.

Japanese Journal of Applied Physics•Oct 1, 2005•10 citations

Kinetic Energy of Trapped Ions Cooled by Buffer Gas

Chen Liang, Lei She, Jiaomei Li +1 more

The average kinetic energy of 40 Ca + ions is measured by the method of evaporating ions in an rf ion trap. The kinetic energy of the ion 40 Ca + varies from 0.5 eV to 0.2eV with changing buffer gas pressure from 10 −7 mbar to 10 −5 mbar. The Brownian motion model is also introduced to calculate the average kinetic energy of the trapped ions.

Chinese Physics Letters•Jun 1, 2010•5 citations

Ion-trajectory analysis for micromotion minimization and the measurement of small forces

Timm F. Gloger, Peter Kaufmann, Delia Kaufmann +4 more

For experiments with ions confined in a Paul trap, minimization of micromotion is often essential. In order to diagnose and compensate micromotion we have implemented a method that allows for finding the position of the radio-frequency (rf) null reliably and efficiently, in principle, without any variation of direct current (dc) voltages. We apply a trap modulation technique and focus-scanning imaging to extract three-dimensional ion positions for various rf drive powers and analyze the power dependence of the equilibrium position of the trapped ion. In contrast to commonly used methods, the search algorithm directly makes use of a physical effect as opposed to efficient numerical minimization in a high-dimensional parameter space. Using this method we achieve a compensation of the residual electric field that causes excess micromotion in the radial plane of a linear Paul trap down to $0.09\phantom{\rule{4pt}{0ex}}\text{V}\phantom{\rule{0.16em}{0ex}}{\text{m}}^{\ensuremath{-}1}$. Additionally, the precise position determination of a single harmonically trapped ion employed here can also be utilized for the detection of small forces. This is demonstrated by determining light pressure forces with a precision of 135 yN. As the method is based on imaging only, it can be applied to several ions simultaneously and is independent of laser direction and thus well suited to be used with, for example, surface-electrode traps.

arXiv:1503.07031•Physical Review A•Oct 27, 2015•45 citations
We have investigated the efficiency of ion trapping in a linear Paul trap. First, we measured the dependence of trapping efficiency on dc and rf voltages using a channel electron multiplier for the direct detection of the electric current of the trapped ions. The most efficient dc and rf voltages were 5.0 and 175 V, respectively. Second, we calculated the trapping efficiency using a simulation code and compared it with the experimental results. We determined that the efficiency of ion trapping decreased monotonically with increasing dc voltage and had an optimum rf voltage. From the numerical calculation, the dependences of trapping efficiency on dc and rf voltages and the initial kinetic energy of ions was derived and the optimum dc and rf voltages and the initial kinetic energy of ions were found to be 0, 210 V, and 1 eV, respectively.
Abstract We present a detailed method for accumulating Ca+ ions controllably in a linear Paul trap. The ions are generated by pulsed laser ablation and dynamically loaded into the ion trap by switching the trapping potential on and off. The loaded ions are precooled by buffer gas and then laser-cooled to form Coulomb crystals for verifying quantity. The number of ions is controlled by manipulating the trapping potential of the ion trap, partial pressure of buffer gas and turn-on time of the entrance end cap voltage. With single-pulse laser ablation, the number of trapped ions ranges from tens to ten thousand. The kinetic energy of loaded ions can be selected via the optimal turn-on time of the entrance end cap. Using multiple-pulse laser ablation, the number is further increased and reaches about 4 × 10 4 . The dynamic loading method has wide application for accumulating low-yielding ions via laser ablation in the ion trap.
We report on the isotope-selective manipulation of Ca + using the laser-heating and laser-cooling techniques in a linear Paul trap. Only 40 Ca + was selectively laser-heated using the optical isotope shift and eliminated from the trap while keeping the target isotope in the trap. The elimination process of the dominant isotope 40 Ca + was investigated and 42, 43, 44, 48 Ca + in the natural isotope mixture of Ca + generated by laser ablation were successfully observed by means of applying the appropriate dc voltage on the end-cap electrodes without changing the laser frequencies, the laser powers and the duration of the laser irradiation. This simplified method enables us to efficiently laser-cool the rare isotopes.
We have fabricated a miniature three-segment linear Paul trap with r 0=0.6 mm and 2Z 0=4 mm. In order to perform quantum-state manipulation of trapped 40 Ca+ ions, we discuss the required harmonic oscillation frequencies which allow us to perform effective sideband cooling and have measured those that depend on the dimensions of the trap. A laser beam that has a component in the radial direction of the linear trap as well as that propagating along the trap axis has been used to detect the fluorescence spectra of the 42 S 1/2–42 P 1/2 transition. We have observed that the profile of the fluorescence spectrum obtained with the side laser beam is markedly different from that obtained with the axial laser beam due to micromotion. By applying additional DC voltages, the micromotion has been compensated, its amplitude has been estimated, and crystallization has been observed for two 40 Ca+ and four 40 Ca+ ions.
For experiments with ions confined in a Paul trap, minimization of micromotion is often essential. In order to diagnose and compensate micromotion we have implemented a method that allows for finding the position of the radio-frequency (rf) null reliably and efficiently, in principle, without any variation of direct current (dc) voltages. We apply a trap modulation technique and focus-scanning imaging to extract three-dimensional ion positions for various rf drive powers and analyze the power dependence of the equilibrium position of the trapped ion. In contrast to commonly used methods, the search algorithm directly makes use of a physical effect as opposed to efficient numerical minimization in a high-dimensional parameter space. Using this method we achieve a compensation of the residual electric field that causes excess micromotion in the radial plane of a linear Paul trap down to $0.09\phantom{\rule{4pt}{0ex}}\text{V}\phantom{\rule{0.16em}{0ex}}{\text{m}}^{\ensuremath{-}1}$. Additionally, the precise position determination of a single harmonically trapped ion employed here can also be utilized for the detection of small forces. This is demonstrated by determining light pressure forces with a precision of 135 yN. As the method is based on imaging only, it can be applied to several ions simultaneously and is independent of laser direction and thus well suited to be used with, for example, surface-electrode traps.