Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

International Journal of Quantum Information

PHASE CONJUGATE MIRRORS, ONE WAY VELOCITY OF LIGHT AND MEASURE OF ANTI-COHERENCE

Augusto Garuccio

Published Feb 1, 2007• 0 citations
Publisher

Abstract

The behavior of phase-conjugate mirrors (PCM) is discussed and a Michelson interferometer with a PCM is described and discussed. This interferometer has been proposed to be used to test the intrinsic non-locality of quantum mechanics and to measure the one-way velocity of light. Moreover, this device can be used in order to measure the intrinsic anticoherence of light.

DOI
10.1142/s0219749907002566

Related papers

Coherent Entangled States, Quantum Mechanics and Relativity

Augusto Garuccio

The behavior of a phase conjugate mirror is discussed and the result of an experiment with a Michelson interferometer with a phase-conjugate mirror is described and commented. This interferometer has been proposed to be used to test the intrinsic non-locality of quantum mechanics. In this paper it is presented a new version of the experimental setup in which entangled coherent states are produced and used.

Fortschritte der Physik•May 1, 2000•4 citations

Coherent Entangled States, Quantum Mechanics and Relativity

Augusto Garuccio

The behavior of a phase conjugate mirror is discussed and the result of an experiment with a Michelson interferometer with a phase-conjugate mirror is described and commented. This interferometer has been proposed to be used to test the intrinsic non-locality of quantum mechanics. In this paper it is presented a new version of the experimental setup in which entangled coherent states are produced and used.

Fortschritte der Physik•May 1, 2000•4 citations

Response of a phase-conjugate mirror to an incident photon

Z. Y. Ou, Samir Bali, L. Mandeļ

The response of a phase-conjugate mirror (PCM) based on nondegenerate four-wave mixing to an incident photon wave packet has been calculated. In the monochromatic limit the phase-compensating property of the PCM, which makes the response independent of optical path length, is recovered. However, for a photon wave packet of nonzero bandwidth, the response of the PCM varies in a fairly complicated manner with the wave-packet length. In particular, the length of the pulse reflected from the PCM becomes independent of the length of the incident pulse for sufficiently short pulses.

Physical Review A•Mar 1, 1989•18 citations

Phase-Conjugate Interferometry

M. D. Ewbank, M. Khoshnevisan, P. Yeh

Unique properties of a phase-conjugate Michelson interferometer are discussed and some applications utilizing this experimental technique are presented. Specifically, the method is used to demonstrate the Doppler-free nature of phase-conjugate reflection.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 23, 1984•2 citations

Optical coherence tomography with phase-sensitive light

Baris I. Erkmen, Jeffrey H. Shapiro

A new configuration for optical coherence tomography is proposed that utilizes a phase-conjugate amplifier in conjunction with a Michelson interferometer to detect interference between two classical light fields with a non-zero phase-sensitive cross correlation. This imaging configuration - which we call phase-conjugate optical coherence tomography (PC-OCT) - shares the same factor-of-two axial resolution improvement and cancellation of even-order dispersion terms that are the key features of quantum optical coherence tomography, but without the necessity for non-classical signal and reference beams. Under appropriate conditions, PC-OCT can achieve a signal-to-noise ratio that is comparable to that of conventional optical coherence tomography.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 31, 2006•4 citations

Quantum theory of interferometers with phase-conjugate mirrors

G. S. Agarwal

The quantum-statistical characteristics of the field at the output port of an interferometer with a phase-conjugate mirror are evaluated. The explicit form of the density matrix of the field at the output port is given. The effect of an attenuator in the other arm of the interferometer is also discussed.

Journal of the Optical Society of America B•Nov 1, 1987•16 citations
The behavior of phase-conjugate mirrors (PCM) is discussed and a Michelson interferometer with a PCM is described and discussed. This interferometer has been proposed to be used to test the intrinsic non-locality of quantum mechanics and to measure the one-way velocity of light. Moreover, this device can be used in order to measure the intrinsic anticoherence of light.
The response of a phase-conjugate mirror (PCM) based on nondegenerate four-wave mixing to an incident photon wave packet has been calculated. In the monochromatic limit the phase-compensating property of the PCM, which makes the response independent of optical path length, is recovered. However, for a photon wave packet of nonzero bandwidth, the response of the PCM varies in a fairly complicated manner with the wave-packet length. In particular, the length of the pulse reflected from the PCM becomes independent of the length of the incident pulse for sufficiently short pulses.
A new configuration for optical coherence tomography is proposed that utilizes a phase-conjugate amplifier in conjunction with a Michelson interferometer to detect interference between two classical light fields with a non-zero phase-sensitive cross correlation. This imaging configuration - which we call phase-conjugate optical coherence tomography (PC-OCT) - shares the same factor-of-two axial resolution improvement and cancellation of even-order dispersion terms that are the key features of quantum optical coherence tomography, but without the necessity for non-classical signal and reference beams. Under appropriate conditions, PC-OCT can achieve a signal-to-noise ratio that is comparable to that of conventional optical coherence tomography.