Journal of Physics B Atomic Molecular and Optical Physics

Angular correlation measurement between the photo-excited autoionized electron and subsequent polarized fluorescent photon at an autoionization resonance of Sr

J. B. West, Kevin J. Ross, Kiyoshi Ueda, H. J. Beyer

Published Aug 14, 1998• 18 citations
Publisher

Abstract

We demonstrate that the technique of measuring the angular correlation between the photoejected electron and polarized fluorescent photon can be used to determine all the photoionization parameters for the relativistic case. Applying this technique to an autoionization resonance of atomic Sr, values were obtained for the ratios of the three dipole amplitudes and the two phase differences.

DOI
10.1088/0953-4075/31/15/002

Related papers

A study of the 4p-excited autoionization resonances in Sr by measurement of the angular correlation between the photoejected electrons and polarized fluorescent photons

Kiyoshi Ueda, John B. West, Kevin J. Ross +2 more

A study of the 4p-excited autoionization resonances in Sr by measurement of the angular correlation between the photoejected electrons and polarized fluorescent photons , K Ueda, J B West, K J Ross, H-J Beyer, N M Kabachnik

Journal of Physics B Atomic Molecular and Optical Physics•Nov 14, 1998•15 citations

Theoretical analysis of angular correlation between the photoelectron and subsequent polarized fluorescent photon in atomic photoionization

N M Kabachnik, Kiyoshi Ueda

The angular correlation between the photoelectron and subsequent polarized fluorescent radiation measured in coincidence is analysed theoretically for atomic photoionization. Using the density matrix and statistical tensor formalism the general expression for the correlation function is obtained for an arbitrary polarized incident photon beam. The particular geometry of a recent experiment (Beyer et al., 1995) is considered and the parameters which determine the angular correlation are expressed in terms of photoionization amplitudes. It is demonstrated that the photoelectron- (polarized) fluorescence coincidence measurements reveal strong circular and linear dichroism. As an example the photoionization of Ca atoms near the 4p 2P3/2 threshold is calculated within the framework of multichannel quantum defect theory.

Journal of Physics B Atomic Molecular and Optical Physics•Dec 14, 1995•18 citations

Angular correlation and entanglement between a spin-polarization-resolved photoelectron and a polarization-resolved fluorescent photon

K. Jänkälä

A theoretical study of the angular correlation and angular variation of entanglement between a photoelectron and a fluorescent photon in photoionization of atoms is provided. The formulation is developed for experiments where spin polarization of a photoelectron and polarization of the subsequent fluorescent photon are detected in a coincidence measurement. The applied formalism of parameterization of all polarization sensitivities of the detectors using Stokes parameters and of the use of statistical and efficiency tensors provides straightforward implementation for any experimental geometry. The framework is demonstrated in the case of calcium photoionization followed by radiative decay.

Journal of Physics B Atomic Molecular and Optical Physics•Aug 6, 2014•1 citation

Circular dichroism in the polarization of the fluorescence resulting from the decay of photoionized Ca atoms

John B. West, Kiyoshi Ueda, N M Kabachnik +3 more

Circular dichroism has been detected in the polarization of the fluorescence resulting from the decay of excited calcium ions. Synchrotron radiation was used to both ionize and excite calcium atoms from their ground state, and the photoejected electron was detected in coincidence with the polarized fluorescent photon. By introducing a degree of left, then right circularly polarized light into the incident photon beam the circular dichroism could be measured. The analysis of the results was carried out using recent developments of the statistical tensor method, and it was possible to determine the sign of the phase difference between the outgoing waves.

Physical Review A•Jan 1, 1996•21 citations

Photoionization polarization spectroscopy of complex atoms

Koichi Nittoh, K Nakayama, Jun Watanabe +3 more

An improved method for the angular momentum measurement of autoionizing levels of complex atoms based on photoionization polarization spectroscopy is reported. In this method, a variation of the ion yield is measured as a function of the combination of the polarizations of the lasers used to excite the autoionizing level through a ladder of intermediate resonant states. Here, eight combinations of different polarizations in three lasers are used, which include not only circular but also linear polarizations. It has been confirmed that the angular momentum of the autoionizing level can be determined uniquely by relative ion-yield measurements for any combination of angular momenta of the levels of the excitation ladders by choosing appropriate intensities of the lasers.

Journal of Physics B Atomic Molecular and Optical Physics•May 28, 1994•9 citations

Complete measurements of two-photon ionization of atomic rubidium using elliptically polarized light

Zheng-Min Wang, Daniel S. Elliott

We report in detail our complete characterization of atomic photoionization via a single measurement, namely, that of the two-photon photoelectron angular distribution using elliptically polarized light. Through these measurements we are able to determine the atomic parameters necessary to unambiguously describe two-photon ionization of atomic rubidium. These parameters include relative cross sections for photoionization into various outgoing channels as well as the phase difference between the continuum S and D partial waves. We present a derivation of the angular distribution with arbitrarily polarized light in terms of these cross sections and phases, demonstrate the advantages of using elliptically polarized light, discuss details of the experiment, and report the results of our measurements in this paper. While measured phase differences are in excellent agreement with expected values over the entire range of photoelectron kinetic energy of our measurements from 0 to 0.5 eV, ratios of cross sections for photoionization into the two D channels are anomalous, suggesting unexpected fine structure effects in these continua.

Physical Review A•Oct 12, 2000•29 citations
We demonstrate that the technique of measuring the angular correlation between the photoejected electron and polarized fluorescent photon can be used to determine all the photoionization parameters for the relativistic case. Applying this technique to an autoionization resonance of atomic Sr, values were obtained for the ratios of the three dipole amplitudes and the two phase differences.
The angular correlation between the photoelectron and subsequent polarized fluorescent radiation measured in coincidence is analysed theoretically for atomic photoionization. Using the density matrix and statistical tensor formalism the general expression for the correlation function is obtained for an arbitrary polarized incident photon beam. The particular geometry of a recent experiment (Beyer et al., 1995) is considered and the parameters which determine the angular correlation are expressed in terms of photoionization amplitudes. It is demonstrated that the photoelectron- (polarized) fluorescence coincidence measurements reveal strong circular and linear dichroism. As an example the photoionization of Ca atoms near the 4p 2P3/2 threshold is calculated within the framework of multichannel quantum defect theory.
A theoretical study of the angular correlation and angular variation of entanglement between a photoelectron and a fluorescent photon in photoionization of atoms is provided. The formulation is developed for experiments where spin polarization of a photoelectron and polarization of the subsequent fluorescent photon are detected in a coincidence measurement. The applied formalism of parameterization of all polarization sensitivities of the detectors using Stokes parameters and of the use of statistical and efficiency tensors provides straightforward implementation for any experimental geometry. The framework is demonstrated in the case of calcium photoionization followed by radiative decay.
Circular dichroism has been detected in the polarization of the fluorescence resulting from the decay of excited calcium ions. Synchrotron radiation was used to both ionize and excite calcium atoms from their ground state, and the photoejected electron was detected in coincidence with the polarized fluorescent photon. By introducing a degree of left, then right circularly polarized light into the incident photon beam the circular dichroism could be measured. The analysis of the results was carried out using recent developments of the statistical tensor method, and it was possible to determine the sign of the phase difference between the outgoing waves.
An improved method for the angular momentum measurement of autoionizing levels of complex atoms based on photoionization polarization spectroscopy is reported. In this method, a variation of the ion yield is measured as a function of the combination of the polarizations of the lasers used to excite the autoionizing level through a ladder of intermediate resonant states. Here, eight combinations of different polarizations in three lasers are used, which include not only circular but also linear polarizations. It has been confirmed that the angular momentum of the autoionizing level can be determined uniquely by relative ion-yield measurements for any combination of angular momenta of the levels of the excitation ladders by choosing appropriate intensities of the lasers.
We report in detail our complete characterization of atomic photoionization via a single measurement, namely, that of the two-photon photoelectron angular distribution using elliptically polarized light. Through these measurements we are able to determine the atomic parameters necessary to unambiguously describe two-photon ionization of atomic rubidium. These parameters include relative cross sections for photoionization into various outgoing channels as well as the phase difference between the continuum S and D partial waves. We present a derivation of the angular distribution with arbitrarily polarized light in terms of these cross sections and phases, demonstrate the advantages of using elliptically polarized light, discuss details of the experiment, and report the results of our measurements in this paper. While measured phase differences are in excellent agreement with expected values over the entire range of photoelectron kinetic energy of our measurements from 0 to 0.5 eV, ratios of cross sections for photoionization into the two D channels are anomalous, suggesting unexpected fine structure effects in these continua.