Australian Journal of Physics

Zero?Field Masers

G S Bogle, H F Symmons

Published Mar 1, 1959• 21 citations
Publisher

Abstract

Solid state three-level masers operating with zero magnetic field are shown to be feasible and to have advantages over magnetic field masers in many applications. The requirements of the working substance are discussed and it is found that compounds of CrH, Fe3+, NiH, and Gd3+ should be suitable.
DOI
10.1071/ph590001

Related papers

An 81-Gc/s zero-field maser

W.E. Hughes, C.R. Kremenek

A zero magnetic field millimeter maser is described which uses the iron ion Fe3+in a host crystalline structure of rutile, TiO2, as the active material. The maser operates as a classical three-level maser [1] between three doubly degenerate zero-field spin levels of the iron ion at a frequency of 81.3 Gc/s and is pumped at a frequency of 124.5 Gc/s. Net gain in excess of 20 dB with instantaneous bandwidths of 3-6 Mc/s have been obtained in a dielectric cavity type configuration.

Proceedings of the IEEE•Jan 1, 1966•0 citations

Operation of a Three-Level Solid-State Maser at 21 cm

J. O. Artman, N. Bloembergen, S. M. Shapiro

Physical Review•Feb 15, 1958•34 citations

Use of Active Material in Three-Level Solid State Masers*

E. O. Schulz-DuBois, H. E. D. Scovil, R. W. DeGrasse

The three-level excitation method for solid state masers, including some background material on paramagnetic resonance, is reviewed. With respect to the experimental application of the maser material, two cases can be distinguished, In the first, maser action is based mainly on a favorable relaxation time ratio in signal and idler transitions. It is shown that the relaxation time ratio can be changed artificially by a doping technique. Experimental evidence is presented for two such doping techniques, one self-doping, the other impurity doping. In the second case, maser action is based primarily on a favorable frequency ratio of signal and idler transitions. Maser experiments using this approach are described. In addition, excitation of unidirectional gain and attenuation by circular polarization is discussed. Properties of practical isolator materials are surveyed; they include high-concentration paramagnetic and polycryslolline ferrimagnetic materials.

Bell System Technical Journal•Mar 1, 1959•25 citations

Microwave Solid State Masers

J D Craggs

By A. E. Siegman London: McGraw-Hill Publishing Co. Ltd. 1964. Pp. 582. Price 143s. 6d. This is a postgraduate book, partly for electronics engineers, who would find a good deal of the material difficult, because it is a comprehensive account of the subject which demands a good deal of familiarity with quantum mechanics. The contents include chapters on internal structure and energy levels of atoms, the magnetic properties of atoms, energy levels of paramagnetic maser materials, paramagnetic resonance and the dynamics of spin systems, the three level solid state maser and travelling wave maser.

Physics Bulletin•Jul 1, 1964•2 citations

Solid-state masers without inversion: Theoretical prediction for high-efficiency oscillators or phase-sensitive detectors

F. F. Popescu

Analytic steady-state solutions of the density-matrix equation are derived by means of a formalism suitable for multilevel spin systems in dilute paramagnetic solids at high temperature and subjected to several strong fields. It is shown that solid-state masers without inversion may be obtained in the presence of one, two, or three quasimonochromatic strong fields at resonance. In the usual cases of two fields, the maser action with or without inversion cannot achieve high-efficiency microwave generation or detection, since for strong emitted fields, the saturating and nonlinear effects are strong too. On the contrary, whenever three frequency-correlated fields fulfill the ``spectroscopic bridge'' conditions, the saturating effects do not occur, and linear effects prevail, even when all these fields are strong. In this case, high-efficiency microwave generations or phase-sensitive detections may be achieved.

Physical review. B, Condensed matter•Nov 1, 1993•9 citations

Perspective on room-temperature solid-state masers

Daan M. Arroo, Neil McN. Alford, Jonathan Breeze

The first solid-state masers to operate at room-temperature and ambient air-pressure were recently demonstrated using optically pumped spin-triplet states as the gain medium. In this Perspective, we briefly review the previous state-of-the-art in cryogenic solid-state masers and then discuss the development of the room-temperature solid-state maser: from the organic pentacene pulsed maser to the diamond nitrogen-vacancy continuous-wave maser. We characterize the operation of these masers as coherent microwave sources and ultra-low noise amplifiers before outlining how they can be adapted to act as model systems in which to explore room-temperature cavity quantum electrodynamics. After discussing challenges facing current embodiments of the room-temperature solid-state maser, we explore how they might be addressed or by-passed altogether through the development of alternative materials and masing mechanisms. Finally, we speculate on how the advent of masers that can operate in ambient conditions might lead to novel applications in metrology and quantum technologies.

Applied Physics Letters•Oct 4, 2021•27 citations
The three-level excitation method for solid state masers, including some background material on paramagnetic resonance, is reviewed. With respect to the experimental application of the maser material, two cases can be distinguished, In the first, maser action is based mainly on a favorable relaxation time ratio in signal and idler transitions. It is shown that the relaxation time ratio can be changed artificially by a doping technique. Experimental evidence is presented for two such doping techniques, one self-doping, the other impurity doping. In the second case, maser action is based primarily on a favorable frequency ratio of signal and idler transitions. Maser experiments using this approach are described. In addition, excitation of unidirectional gain and attenuation by circular polarization is discussed. Properties of practical isolator materials are surveyed; they include high-concentration paramagnetic and polycryslolline ferrimagnetic materials.
By A. E. Siegman London: McGraw-Hill Publishing Co. Ltd. 1964. Pp. 582. Price 143s. 6d. This is a postgraduate book, partly for electronics engineers, who would find a good deal of the material difficult, because it is a comprehensive account of the subject which demands a good deal of familiarity with quantum mechanics. The contents include chapters on internal structure and energy levels of atoms, the magnetic properties of atoms, energy levels of paramagnetic maser materials, paramagnetic resonance and the dynamics of spin systems, the three level solid state maser and travelling wave maser.
Analytic steady-state solutions of the density-matrix equation are derived by means of a formalism suitable for multilevel spin systems in dilute paramagnetic solids at high temperature and subjected to several strong fields. It is shown that solid-state masers without inversion may be obtained in the presence of one, two, or three quasimonochromatic strong fields at resonance. In the usual cases of two fields, the maser action with or without inversion cannot achieve high-efficiency microwave generation or detection, since for strong emitted fields, the saturating and nonlinear effects are strong too. On the contrary, whenever three frequency-correlated fields fulfill the ``spectroscopic bridge'' conditions, the saturating effects do not occur, and linear effects prevail, even when all these fields are strong. In this case, high-efficiency microwave generations or phase-sensitive detections may be achieved.
The first solid-state masers to operate at room-temperature and ambient air-pressure were recently demonstrated using optically pumped spin-triplet states as the gain medium. In this Perspective, we briefly review the previous state-of-the-art in cryogenic solid-state masers and then discuss the development of the room-temperature solid-state maser: from the organic pentacene pulsed maser to the diamond nitrogen-vacancy continuous-wave maser. We characterize the operation of these masers as coherent microwave sources and ultra-low noise amplifiers before outlining how they can be adapted to act as model systems in which to explore room-temperature cavity quantum electrodynamics. After discussing challenges facing current embodiments of the room-temperature solid-state maser, we explore how they might be addressed or by-passed altogether through the development of alternative materials and masing mechanisms. Finally, we speculate on how the advent of masers that can operate in ambient conditions might lead to novel applications in metrology and quantum technologies.