Applied Optics

Line-shape studies for single- and triple-pass Fabry–Perot interferometer systems

Edward D. Palik, Hacène Boukari, Robert W. Gammon

Published Jan 1, 1995• 7 citations
Publisher

Abstract

To test the model developed in the preceding paper [Appl. Opt. 34, this issue (1994)] regarding the line shape produced by a Fabry-Perot interferometer system in a multipass mode, we have used three Lorentzian line shapes formed in scattering processes and subjected them to single and triple passes with some variation in the pinhole diameter. In most cases we find good agreement with the calculations with the only adjustable parameter being the single-pass contrast C(1). Where differences occur, plausible explanations are offered.

DOI
10.1364/ao.34.000058

Related papers

Line shape studies for single- and triple-pass Fabry-Perot interferometer systems

Edward D. Palik, Hacène Boukari, Robert W. Gammon

We utilized the theory in the preceding paper to determine the effect of 1- and 3-passes through a Fabry-Perot interferometer on the natural line shape of two different Lorentzian lines.

Annual Meeting Optical Society of America•Jan 1, 1993•0 citations

Measurement of Absorption-Line Profiles with a Fabry–Perot Interferometer*

Robert J. Hull, Lee C. Bradley

We have calculated the line profiles to be expected when a Fabry–Perot interferometer is used to measure absorption lines. We have shown that large errors may be introduced in the measurement of the integrated absorption, even when an interferometer of high finesse is used. Curves and tables are given for finding the true absorption width and the true peak absorption from the apparent values observed under different operating conditions of the emission light source and the interferometer. We show qualitatively that the distortions are partially due to the presence of nonzero wings in the instrument-bandpass function. Finally, we show a Fourier series expansion of the integral giving the transmittance of the Fabry-Perot interferometer when absorbing atoms are in the light path.

Journal of the Optical Society of America•Jan 1, 1967•8 citations

The Response of Scanning Fabry-Perot Interferometers to Atomic Transition Profiles

Edward A. Ballik

Get PDF Email Share Share with Facebook Tweet This Post on reddit Share with LinkedIn Add to CiteULike Add to Mendeley Add to BibSonomy Get Citation Copy Citation Text E. A. Ballik, "The Response of Scanning Fabry-Perot Interferometers to Atomic Transition Profiles," Appl. Opt. 5, 170_1-172 (1966) Export Citation BibTex Endnote (RIS) HTML Plain Text Citation alert Save article

Applied Optics•Jan 1, 1966•77 citations

Line-shape analysis of resonant energy transfer collisions

James Veale, W. Anderson, M. Gatzke +2 more

We have investigated the resonant collision process 26s+24d\ensuremath{\rightarrow}26p+25p in K, which occurs when the 26s and 24d states are tuned by a static electric field so that the intervals 26s-26p and 24d-25p are equal. Resonant collision line shapes are observed and analyzed for three collision velocity distributions: a thermal beam, a small band of velocities in a laser-cooled beam, and two well-separated velocity groups in a laser-cooled beam. Collisions between atoms with a broad distribution of relative velocities produce cusp line shapes. In contrast, collisions occurring between atoms in two well-defined velocity groups produce approximately Lorentzian line shapes. \textcopyright{} 1996 The American Physical Society.

Physical Review A•Aug 1, 1996•7 citations

A Note on the Resonant Modes and Spatial Coherency of a Fabry-Perot Maser Interferometer

G. J. Fan

This communication has considered the case of a Fabry-Perot cavity with light impinging on one end while the field distribution on the other end is observed. It has been shown that if one starts with a wave that can be expanded into the modes of the integral operator, and if the medium in the cavity is passive, more than one mode would be observed at the other end although the amplitude of the dominant mode can be much greater than that of the other modes. It was further shown that if there is present an active medium with sufficient gain there will be only a single mode, and the single mode is necessary and sufficient for complete spatial coherency.

IBM Journal of Research and Development•Jul 1, 1964•4 citations

Nonlinear properties of Fabry-Perot interferometer in the conditions of inhomogeneous broadening of electron paramagnetic resonance (EPR) line

Alexey A. Vertiy

Investigation of behaviour of a nonlinear Fabry-Perot interferometer with a paramagnetic filling in the conditions of inhomogeneous broadening of the electron paramagnetic resonance line is of interest for different implementations in the spectroscopy, quasioptics and dynamic nuclear polarisation.

International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz)•Oct 1, 1991•0 citations
To test the model developed in the preceding paper [Appl. Opt. 34, this issue (1994)] regarding the line shape produced by a Fabry-Perot interferometer system in a multipass mode, we have used three Lorentzian line shapes formed in scattering processes and subjected them to single and triple passes with some variation in the pinhole diameter. In most cases we find good agreement with the calculations with the only adjustable parameter being the single-pass contrast C(1). Where differences occur, plausible explanations are offered.
We have calculated the line profiles to be expected when a Fabry–Perot interferometer is used to measure absorption lines. We have shown that large errors may be introduced in the measurement of the integrated absorption, even when an interferometer of high finesse is used. Curves and tables are given for finding the true absorption width and the true peak absorption from the apparent values observed under different operating conditions of the emission light source and the interferometer. We show qualitatively that the distortions are partially due to the presence of nonzero wings in the instrument-bandpass function. Finally, we show a Fourier series expansion of the integral giving the transmittance of the Fabry-Perot interferometer when absorbing atoms are in the light path.
We have investigated the resonant collision process 26s+24d\ensuremath{\rightarrow}26p+25p in K, which occurs when the 26s and 24d states are tuned by a static electric field so that the intervals 26s-26p and 24d-25p are equal. Resonant collision line shapes are observed and analyzed for three collision velocity distributions: a thermal beam, a small band of velocities in a laser-cooled beam, and two well-separated velocity groups in a laser-cooled beam. Collisions between atoms with a broad distribution of relative velocities produce cusp line shapes. In contrast, collisions occurring between atoms in two well-defined velocity groups produce approximately Lorentzian line shapes. \textcopyright{} 1996 The American Physical Society.
This communication has considered the case of a Fabry-Perot cavity with light impinging on one end while the field distribution on the other end is observed. It has been shown that if one starts with a wave that can be expanded into the modes of the integral operator, and if the medium in the cavity is passive, more than one mode would be observed at the other end although the amplitude of the dominant mode can be much greater than that of the other modes. It was further shown that if there is present an active medium with sufficient gain there will be only a single mode, and the single mode is necessary and sufficient for complete spatial coherency.