Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)

Comparing PTB's optical 171Yb+ ion and 87Sr lattice clock

Christian Grebing, St. Falke, Nils Huntemann, N. Lemke, B. Lipphardt, Uwe Sterr, Chr. Tamm, H. Schnatz, E. Peik, Christian Lisdat

Published May 1, 2013• 0 citations
Publisher

Abstract

At PTB we have performed a comparison between a171Yb+single ion clock (octupole transition) and a87Sr clock interrogating an ensemble of atoms captured in an optical lattice.
DOI
10.1109/cleoe-iqec.2013.6801751

Related papers

10-18 Optical Atomic Clock Comparisons within the Boulder Atomic Clock Network

Nicholas V. Nardelli, K. Beloy, Martha I. Bodine +35 more

We demonstrate optical frequency comparison of the 171Yb, 27Al+ and 87Sr atomic clocks with measurement uncertainties below 1 part in 1017, and discuss how phase-coherent and synchronous clock comparisons can be used to improve measurement stability.

Conference on Lasers and Electro-Optics•Jan 1, 2020•0 citations

Towards a compact transportable optical clock based on the octupole transition in 171Yb+

Xuanjian Wang, Jian Zhong Cao, Hualin Shu +5 more

arXiv:2510.10476•Applied Physics B•Nov 12, 2025•1 citation

Industrial 171Yb+ single-ion optical clock with systematic uncertainty below 2×10^−17

J. Stühler, A. Friedenauer, P. Thoumany +3 more

We present the setup of our optical frequency standard (OFS) “TOPTICLOCK”. It is based on the 2S1/2 (F=0) – 2D3/2 (F=2) electric quadrupole transition at 435.5 nm of a single laser-cooled and trapped 171Yb+ ion. All required subsystems are contained in two transportable 19” rack compartments. By comparing it with a laboratory-style OFS of the German National Metrology Institute (PTB), which operates on the 467 nm electric octupole transition, using a TOPTICA DFC optical frequency comb, a frequency instability of 5×10-15/√τ with systematic uncertainty below 2×10-17 was demonstrated. The performance of TOPTICLOCK was also benchmarked by directly comparing it to another OFS operating also at the 435.5 nm clock transition. An agreement between both systems with a total uncertainty well below 10-17 was obtained.

Optical and Quantum Sensing and Precision Metrology II•Mar 5, 2026•2 citations

Trapped ion optical frequency standards

Patrick Robert Gill, G. P. Barwood, Hugh A. Klein +6 more

Optical frequency standards based on narrow absorptions in laser-cooled single trapped ions have recently begun to demonstrate stabilities that are competitive with cold atom fountain microwave standards. This paper presents a short review of the wider state-of-the-art development of these single cold trapped ion frequency standards, coupled with a more detailed account of recent results achieved at National Physical Laboratory in respect of single ion systems based on 88Sr+, 87Sr+ and 171Yb+. Narrow linewidth data for the optical clock quadrupole and octupole transitions respectively at 674 nm in 88Sr+ and 467 nm in 171Yb+, are presented, together with a discussion of current systematics and future projections. The potential for optical clock operation is outlined.

Measurement Science and Technology•Jul 16, 2003•44 citations

Systematic Study of the $^{87}$Sr Clock Transition in an Optical Lattice

Martin M. Boyd, Andrew D. Ludlow, Tanya Zelevinsky +5 more

Bulletin of the American Physical Society•May 18, 2006•62 citations

Leveraging correlated laser noise to improve optical frequency comparisons

Ethan Clements, M. Bohman, May E. Kim +14 more

Laser noise usually limits the stability of optical frequency ratio measurements, limiting the speed and precision one can compare two atomic frequency standards. In this talk I will describe two methods, correlation and differential spectroscopy, which utilize correlations in laser noise to increase the achievable interrogation time and thus increase the frequency comparison stability. Correlation spectroscopy is a technique which uses a parity measurement following a synchronized Ramsey interrogation to measure the relative frequency of two similar frequency atomic clocks. With this technique we achieve a measurement instability of (4×10^(-16))⁄√(τ⁄s) for a comparison of two single 27Al+ ion clocks. Differential spectroscopy uses an atomic clock with low projection noise, here a 171Yb lattice clock, to correct the phase noise of a second, higher frequency clock’s local oscillator thereby reducing the measurement instability to the level of the first. This can be further extended using two lattice clocks in a zero dead time configuration to correct the phase noise beyond the interrogation time reachable for a single Yb lattice clock. With these techniques we achieve measurement stabilities of (2.5×10^(-16))⁄√(τ⁄s) and (2×10^(-16))⁄√(τ⁄s) for a comparison between a single 27Al+ ion clock and a 171Yb lattice clock running as single clock and in a zero dead time configuration respectively. In addition to these techniques, I will also discuss recent progress towards characterizing the systematics of the NIST 40Ca+/27Al+ optical atomic clock.

Optical and Quantum Sensing and Precision Metrology II•Mar 9, 2022•0 citations
We present the setup of our optical frequency standard (OFS) “TOPTICLOCK”. It is based on the 2S1/2 (F=0) – 2D3/2 (F=2) electric quadrupole transition at 435.5 nm of a single laser-cooled and trapped 171Yb+ ion. All required subsystems are contained in two transportable 19” rack compartments. By comparing it with a laboratory-style OFS of the German National Metrology Institute (PTB), which operates on the 467 nm electric octupole transition, using a TOPTICA DFC optical frequency comb, a frequency instability of 5×10-15/√τ with systematic uncertainty below 2×10-17 was demonstrated. The performance of TOPTICLOCK was also benchmarked by directly comparing it to another OFS operating also at the 435.5 nm clock transition. An agreement between both systems with a total uncertainty well below 10-17 was obtained.
Optical frequency standards based on narrow absorptions in laser-cooled single trapped ions have recently begun to demonstrate stabilities that are competitive with cold atom fountain microwave standards. This paper presents a short review of the wider state-of-the-art development of these single cold trapped ion frequency standards, coupled with a more detailed account of recent results achieved at National Physical Laboratory in respect of single ion systems based on 88Sr+, 87Sr+ and 171Yb+. Narrow linewidth data for the optical clock quadrupole and octupole transitions respectively at 674 nm in 88Sr+ and 467 nm in 171Yb+, are presented, together with a discussion of current systematics and future projections. The potential for optical clock operation is outlined.
Systematic Study of the 87^{87}87Sr Clock Transition in an Optical Lattice
Laser noise usually limits the stability of optical frequency ratio measurements, limiting the speed and precision one can compare two atomic frequency standards. In this talk I will describe two methods, correlation and differential spectroscopy, which utilize correlations in laser noise to increase the achievable interrogation time and thus increase the frequency comparison stability. Correlation spectroscopy is a technique which uses a parity measurement following a synchronized Ramsey interrogation to measure the relative frequency of two similar frequency atomic clocks. With this technique we achieve a measurement instability of (4×10^(-16))⁄√(τ⁄s) for a comparison of two single 27Al+ ion clocks. Differential spectroscopy uses an atomic clock with low projection noise, here a 171Yb lattice clock, to correct the phase noise of a second, higher frequency clock’s local oscillator thereby reducing the measurement instability to the level of the first. This can be further extended using two lattice clocks in a zero dead time configuration to correct the phase noise beyond the interrogation time reachable for a single Yb lattice clock. With these techniques we achieve measurement stabilities of (2.5×10^(-16))⁄√(τ⁄s) and (2×10^(-16))⁄√(τ⁄s) for a comparison between a single 27Al+ ion clock and a 171Yb lattice clock running as single clock and in a zero dead time configuration respectively. In addition to these techniques, I will also discuss recent progress towards characterizing the systematics of the NIST 40Ca+/27Al+ optical atomic clock.