Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of the Optical Society of America B

Spectrum of squeezing and photocurrent shot noise: a normally ordered treatment

H. J. Carmichael

Published Oct 1, 1987• 140 citations
Publisher

Abstract

The detection of squeezed optical fields generated by intracavity nonlinear-optical interactions is described. The relationship between quantum-statistical properties of the cavity mode and those of the field at a detector placed outside the cavity discussed. The detected field is composed of a source field from the cavity plus a free external field. The free field couples weakly to the cavity so that it is correlated with the source field. The photocurrent spectrum in optical homodyne detection is calculated, and the spectrum of squeezing is defined. This spectrum can be calculated entirely in terms of intracavity fields without requiring knowledge of the correlations between source and free-field contributions in the cavity output. This follows from an explicitly normally ordered, time-ordered treatment of the photodetection problem. Contrasting earlier treatments of photodetection for squeezed fields, in a normally ordered approach, shot noise arises naturally from the self-correlation of photocurrent for pulses. The derived spectrum is converted into nonnormally ordered, non-time-ordered form to recover the results of these earlier treatments and their interpretation of shot noise in terms of local-oscillator quantum noise, signal and quantum noise, and detector-efficiency quantum noise.

DOI
10.1364/josab.4.001588

Related papers

Direct detection of Gaussian state light

Jeffrey H. Shapiro, Ke-Xun Sun

The quantum theory of photodetection is applied to the direct detection of multi-mode Gaussian-state light, with particular attention to the mean photocurrent and the photocurrent noise spectrum. Gaussian-state light comprises squeezed-state light plus additional classical Gaussian noise. By extending the familiar Gaussian moment-factoring formula of classical statistics to the antinormally ordered characteristic function of Gaussian-state light, the first and second moment photocurrent statistics for such illumination are shown to be completely characterized by knowledge of the mean function, the phase-sensitive correlation function, and the normally ordered correlation of the input light. The theory delineates the condition under which the strong-mean-field approximation is applicable to direct detection of such beams, i.e., it tells us when a direct detector yields the same noise spectrum as that of an in-phase homodyne detector. Numerical results are presented for the noise spectra of a squeezed amplifier, i.e., an optical parametric amplifier with signal-injection-induced gain saturation.

Annual Meeting Optical Society of America•Jan 1, 1992•0 citations

Squeezing for Intracavity generated light in the master equation approach

H. J. Carmichael

Master equation methods provide useful tools for analyzing the statistics of quantum optical systems. They focus attention on a simple system of interest (a single cavity mode, for example), accounting for its interaction with its environment in parameters describing decay rates and environmental fluctuations. Intracavity systems for generating squeezed light are prime candidates for analysis by these methods. It has been shown, however, that it is important in such analysis to distinguish between the statistics of the intracavity field and the statistics of the field generated outside the cavity by transmission through the cavity mirrors.1,2 It is desirable to perform calculations with the single mode inside the cavity. Then the statistics of the multimode field outside the cavity must be related to those of the internal mode. The situation is analogous to that in resonance fluorescence, where the statistics of the fluorescent field can be calculated in terms of the source dipole operator. In this paper the field outside an optical cavity is expressed in terms of the intracavity oscillator as a source. The measurement of squeezing in the external field is then related to the correlation properties of the cavity source operator. Measurement by photon counting of homodyned light is related to the spectrum of squeezing calculated by Walls and co-workers.

Annual Meeting Optical Society of America•Jan 1, 1986•0 citations

Correlation spectroscopy with squeezed light

V. V. Batygin, Dmitriy V. Kupriyanov, Igor M. Sokolov

We have discussed the possibilities of correlation spectroscopy (light beating spectroscopy) technique if squeezed light is used as a probe radiation for medium monitoring. The dispersion of the fluctuation of photocurrent spectrum measured in this method is expressed in terms of fourth order photocurrent correlation function. This correlation function is considered and evaluated in assumptions of photodetection theory developed by Glauber in first nonvanishing orders in interaction of probe light with the atoms of a photodetector. We show that fourth order correlation function is determined by all field TN-ordered amplitude correlation functions up to the fourth order. In case of heterodyne detection, when the light incident on photodetector surface is the mix of strong coherent modes of local oscillator wave and weak non-coherent (squeezed) modes, the observable (photocurrent spectrum) as well as its fluctuation (noise of photocurrent spectrum) is expressed in terms of spectrum-dependent Mandel parameter. We have discussed possible improvement of sensitivity limit for correlation spectroscopy in this case.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 6, 1996•0 citations

Squeezed-state generation in optical bistability

Luis A. Orozco, Mark G. Raizen, Min Xiao +2 more

Experiments to generate squeezed states of light are described for a collection of two-level atoms within a high-finesse cavity. The investigation is conducted in a regime for which the weak-field coupling of atoms to the cavity mode produces a splitting in the normal mode structure of the atom–field system that is large compared with the atomic linewidth. Reductions in photocurrent noise of 30% (−1.55 dB) below the noise level set by the vacuum state of the field are observed in a balanced homodyne detector. A degree of squeezing of approximately 50% is inferred for the field state in the absence of propagation and detection losses. The observed spectrum of squeezing extends over a very broad range of frequencies (~±75 MHz), with the frequency of best squeezing corresponding to an offset from the optical carrier given by the normal mode splitting.

Journal of the Optical Society of America B•Oct 1, 1987•86 citations

Optimizing homodyne detection of quadrature-noise squeezing by local-oscillator selection

Jeffrey H. Shapiro, Asif Shakeel

A general formalism is developed for optimizing homodyne detection of quadrature-noise squeezing by selection of the local-oscillator (LO) field. The optimum LO is the minimum-eigenvalue eigenfunction of a particular Fredholm integral equation whose kernel depends on the signal field's normally ordered and phase-sensitive covariance functions. The squeezing that results from use of the optimum LO equals one plus twice its associated eigenvalue. A continuous-wave (cw) simplification of the general formalism is presented for the case of stationary signal-field covariances when the homodyne photocurrent is spectrum analyzed. Another simplified special case is exhibited for single-spatial-mode operation, such as is encountered in fiber-based quantum-noise experiments. The cw-source–spectrum-analysis approach is used to determine the optimum LO field and its squeezing performance for cw squeezed-state generation in a bulk Kerr medium with a Gaussian spatial-response function. The single-spatial-mode framework is employed to find the optimum LO field and its squeezing performance for pulsed squeezed-state generation in a single-mode optical fiber whose Kerr nonlinearity has a noninstantaneous response function. Comparison of the cw limit of this pulsed analysis with previous cw fiber-squeezing theory reveals a new regime for quadrature-noise reduction: Raman squeezing in fiber four-wave mixing.

Journal of the Optical Society of America B•Feb 1, 1997•33 citations

Generation of squeezed light by intracavity frequency doubling

Silvania F. Pereira, Min Xiao, Harry J. Kimble +1 more

Squeezed states of light are generated by the process of second-harmonic conversion within an optical cavity resonant at both fundamental and harmonic frequencies. Observations of squeezing are made by analyzing the spectral density of photocurrent fluctuations produced by the total field reflected from the nonlinear cavity. Reductions in photocurrent noise of 13% relative to the coherent-state or shot-noise level are achieved for frequency offsets near 4 MHz.

Physical Review A•Nov 1, 1988•175 citations
The detection of squeezed optical fields generated by intracavity nonlinear-optical interactions is described. The relationship between quantum-statistical properties of the cavity mode and those of the field at a detector placed outside the cavity discussed. The detected field is composed of a source field from the cavity plus a free external field. The free field couples weakly to the cavity so that it is correlated with the source field. The photocurrent spectrum in optical homodyne detection is calculated, and the spectrum of squeezing is defined. This spectrum can be calculated entirely in terms of intracavity fields without requiring knowledge of the correlations between source and free-field contributions in the cavity output. This follows from an explicitly normally ordered, time-ordered treatment of the photodetection problem. Contrasting earlier treatments of photodetection for squeezed fields, in a normally ordered approach, shot noise arises naturally from the self-correlation of photocurrent for pulses. The derived spectrum is converted into nonnormally ordered, non-time-ordered form to recover the results of these earlier treatments and their interpretation of shot noise in terms of local-oscillator quantum noise, signal and quantum noise, and detector-efficiency quantum noise.
The quantum theory of photodetection is applied to the direct detection of multi-mode Gaussian-state light, with particular attention to the mean photocurrent and the photocurrent noise spectrum. Gaussian-state light comprises squeezed-state light plus additional classical Gaussian noise. By extending the familiar Gaussian moment-factoring formula of classical statistics to the antinormally ordered characteristic function of Gaussian-state light, the first and second moment photocurrent statistics for such illumination are shown to be completely characterized by knowledge of the mean function, the phase-sensitive correlation function, and the normally ordered correlation of the input light. The theory delineates the condition under which the strong-mean-field approximation is applicable to direct detection of such beams, i.e., it tells us when a direct detector yields the same noise spectrum as that of an in-phase homodyne detector. Numerical results are presented for the noise spectra of a squeezed amplifier, i.e., an optical parametric amplifier with signal-injection-induced gain saturation.
Master equation methods provide useful tools for analyzing the statistics of quantum optical systems. They focus attention on a simple system of interest (a single cavity mode, for example), accounting for its interaction with its environment in parameters describing decay rates and environmental fluctuations. Intracavity systems for generating squeezed light are prime candidates for analysis by these methods. It has been shown, however, that it is important in such analysis to distinguish between the statistics of the intracavity field and the statistics of the field generated outside the cavity by transmission through the cavity mirrors.1,2 It is desirable to perform calculations with the single mode inside the cavity. Then the statistics of the multimode field outside the cavity must be related to those of the internal mode. The situation is analogous to that in resonance fluorescence, where the statistics of the fluorescent field can be calculated in terms of the source dipole operator. In this paper the field outside an optical cavity is expressed in terms of the intracavity oscillator as a source. The measurement of squeezing in the external field is then related to the correlation properties of the cavity source operator. Measurement by photon counting of homodyned light is related to the spectrum of squeezing calculated by Walls and co-workers.
We have discussed the possibilities of correlation spectroscopy (light beating spectroscopy) technique if squeezed light is used as a probe radiation for medium monitoring. The dispersion of the fluctuation of photocurrent spectrum measured in this method is expressed in terms of fourth order photocurrent correlation function. This correlation function is considered and evaluated in assumptions of photodetection theory developed by Glauber in first nonvanishing orders in interaction of probe light with the atoms of a photodetector. We show that fourth order correlation function is determined by all field TN-ordered amplitude correlation functions up to the fourth order. In case of heterodyne detection, when the light incident on photodetector surface is the mix of strong coherent modes of local oscillator wave and weak non-coherent (squeezed) modes, the observable (photocurrent spectrum) as well as its fluctuation (noise of photocurrent spectrum) is expressed in terms of spectrum-dependent Mandel parameter. We have discussed possible improvement of sensitivity limit for correlation spectroscopy in this case.
Experiments to generate squeezed states of light are described for a collection of two-level atoms within a high-finesse cavity. The investigation is conducted in a regime for which the weak-field coupling of atoms to the cavity mode produces a splitting in the normal mode structure of the atom–field system that is large compared with the atomic linewidth. Reductions in photocurrent noise of 30% (−1.55 dB) below the noise level set by the vacuum state of the field are observed in a balanced homodyne detector. A degree of squeezing of approximately 50% is inferred for the field state in the absence of propagation and detection losses. The observed spectrum of squeezing extends over a very broad range of frequencies (~±75 MHz), with the frequency of best squeezing corresponding to an offset from the optical carrier given by the normal mode splitting.
A general formalism is developed for optimizing homodyne detection of quadrature-noise squeezing by selection of the local-oscillator (LO) field. The optimum LO is the minimum-eigenvalue eigenfunction of a particular Fredholm integral equation whose kernel depends on the signal field's normally ordered and phase-sensitive covariance functions. The squeezing that results from use of the optimum LO equals one plus twice its associated eigenvalue. A continuous-wave (cw) simplification of the general formalism is presented for the case of stationary signal-field covariances when the homodyne photocurrent is spectrum analyzed. Another simplified special case is exhibited for single-spatial-mode operation, such as is encountered in fiber-based quantum-noise experiments. The cw-source–spectrum-analysis approach is used to determine the optimum LO field and its squeezing performance for cw squeezed-state generation in a bulk Kerr medium with a Gaussian spatial-response function. The single-spatial-mode framework is employed to find the optimum LO field and its squeezing performance for pulsed squeezed-state generation in a single-mode optical fiber whose Kerr nonlinearity has a noninstantaneous response function. Comparison of the cw limit of this pulsed analysis with previous cw fiber-squeezing theory reveals a new regime for quadrature-noise reduction: Raman squeezing in fiber four-wave mixing.