Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Optics

Optical random number generator based on photoevent locations

Anthony J. Martino, G. Michael Morris

Published Mar 10, 1991• 22 citations
Publisher

Abstract

A 2-D position-sensitive photon-counting detector is used in an optical random number generator in which the locations of detected photoevents provide the random numbers. The spatial distribution of photoevent locations is dictated by imaging a control object onto the detector. An iterative calibration procedure is used to determine the brightness distribution of the control object. Two control objects were examined-film and a video monitor. With both control objects, the performance of the optical random number generator approached that of pseudorandom number generators.

DOI
10.1364/ao.30.000981

Related papers

Optical generation of random numbers: theory and experiments

Anthony J. Martino, G. Michael Morris

Simulation of physical processes and Monte Carlo solutions to numerical problems on digital computers require sources of random numbers that follow specified density functions. In our experiments, the spatial coordinates of detected photoevents are used as a fast source of true random numbers to solve numerical problems by the Monte Carlo method. The probability density function for the location of a photoevent on the detector surface is proportional to the irradiance. We have constructed an optical random number generator using a microchannel plate detector with a resistive anode. It can produce bivariate random deviates with any probability density and any correlation between the two variables. The numbers pass the standard tests for randomness and fit to the given distributions (chi-square, correlation, sequence tests). Nonuniform distributions can be obtained with no loss of speed by manipulating the irradiance distribution across the detector, e.g., by imaging a transparency onto it. In particular, we have produced uniformly distributed random numbers and normally distributed random numbers with various correlations between the variables. We have also used the optical random number generator to find approximate solutions to systems of large linear algebraic equations and approximations to the inverses of large matrices, with a maximum error of <5%.

Annual Meeting Optical Society of America•Jan 1, 1985•1 citation

A Optical Random Number Generator Based on Photoevent Locations

Anthony J. Martino

•Jan 1, 1990•0 citations

Generation of physical random numbers by means of photon counting

知恵 末松, Naoto Namekata, 一平 島田 +1 more

Abstract Random numbers were generated using the probabilistic behavior of a single photon in an optical fiber coupler. An optical fiber coupler (1:1 split ratio) distributes with equal probability a single photon to two optical paths. Therefore, a binary random number sequence was obtained. This random number generation rate was 2.94 Mbit/s. We found from the results of examining the obtained random number sequence that correlation appears between adjacent numbers of random numbers because there is a dead‐time (Td=50ns) in the photon detector. Therefore, we created a new random number sequence by sampling every second random number. This random number sequence did pass statistical tests for independence and uniformity. Consequently, the random number generation rate was 1.47 Mbit/s. © 2006 Wiley Periodicals, Inc. Electron Comm Jpn Pt 3, 90(2): 1–8, 2007; Published online in Wiley InterScience ( www.interscience.wiley.com ). DOI 10.1002/ecjc.20229

Electronics and Communications in Japan (Part III Fundamental Electronic Science)•Oct 10, 2006•3 citations

Optical Quantum Random Number Generator Based on Parity of the Number of Photons Detected in Equal Time Intervals

鄢秋荣 YAN Qiu-rong, 赵宝升 ZHAO Bao-sheng, 张华 ZHANG Hua +2 more

An optical quantum random number generator based on parity of the number of photons detected in the equal time intervals was proposed. Light emitted from a continuous wave laser diode is attenuated into discrete single-photon sequence. The single photon is detected by a single-photon avalanche photodiode module. Random bit is extracted by measuring the parity of number of photons detected in equal time interval. The random bit extraction circuit based on field programmable gate array was developed. The influences of the size of time interval and the performance parameters of single photon module on performance of the designed random number generator were analyzed. In order to achieve a random bit generator with small deviation and fast generation rate, a method of setting time interval automatically according to average counting rate was proposed. A random bit generation rate of 2 Mbit/s was obtained when the designed random number generator works on a counting rate of 20 Mcps and the equal time interval is set as 0.5 μs. The random bit sequences were tested by random number test program ENT and STS. The test results show that the generated random bit sequences fully meet the standards of true random numbers, and do not require post-processin ©, 2015, Chinese Optical Society. All right reserved.

ACTA PHOTONICA SINICA•Jan 1, 2015•0 citations

Noise in Classical and Quantum Photon-Correlation Imaging

Bahaa E. A. Saleh, Malvin Carl Teich

Imaging is the estimation of the spatial distribution of a physical object by measuring the optical radiation it emits, or by making use of an optical wave that interacts with the object, via reflection or transmission, for example, before being measured by a detector. The resolution of an imaging system is limited by the inability to localize the optical field at points of the object. Under otherwise ideal conditions, resolution is limited by diffraction. The sensitivity of an imaging system is limited by the uncertainty in the measurement. Under ideal conditions, this is determined by photon noise, which depends on the statistical fluctuations of the light. In conventional imaging systems, an extended detector, such as a CCD camera or an array detector, measures the spatial distribution of the optical intensity, which is proportional to the photon flux density. In interferometric systems, the spatial distribution of the optical field is inferred from measurements of the optical intensity. With the emergence of coherence theory, imaging systems based on measurements of the second-order coherence function at pairs of points in the detection plane were developed. An example is the imaging of an incoherent object based on the van Cittert-Zernike theorem. Imaging systems based on measurement of intensity correlation, or the photon coincidence rate, at pairs of points, were developed in the 1960s. A classic example of the photon-correlation imaging of an object emitting thermal light is stellar imaging using a Hanbury-Brown-Twiss intensity-correlation interferometer. More recently, two-photon light, which may be generated via spontaneous parametric downconversion in a second-order nonlinear optical crystal, has been used for imaging. This type of two-photon (or biphoton) imaging, which has come to be called quantum imaging, is also based on the measurement of photon coincidence by the use of photon-counting array detectors or by scanning two photon-counting detectors at pairs of points. To compare the resolution and sensitivity of imaging systems based on the aforementioned types of measurements, it is necessary to derive expressions for the measured quantities in terms of the object distribution. The point-spread functions based on such expressions can be used to assess the resolution. One measure of the sensitivity of the imaging process is the signal-to-noise ratio (SNR) of the measured variables. The statistical nature of the light source must be known in order to determine the SNR. The purpose of this chapter is to compare the resolution and sensitivity of photon-correlation imaging systems that make use of thermal light and two-photon light. We will henceforth refer to these two imaging modalities as classical and quantum photon-correlation imaging, or simply classical and quantum imaging, respectively. Clearly, light in other quantum states can also be used for imaging.

SPIE eBooks•Mar 16, 2010•4 citations

Quantum random number generators

J. E. Nordholt

Random number generators include a thermal optical source and detector configured to produce random numbers based on quantum-optical intensity fluctuations. An optical flux is detected, and signals proportional to optical intensity and a delayed optical intensity are combined. The combined signals can be electrical signals or optical signals, and the optical source is selected so as to have low coherence over a predetermined range of delay times. Balanced optical detectors can be used to reduce common mode noise, and in some examples, the optical flux is directed to only one of a pair of balanced detectors.

•Jan 23, 2023•1 citation
A 2-D position-sensitive photon-counting detector is used in an optical random number generator in which the locations of detected photoevents provide the random numbers. The spatial distribution of photoevent locations is dictated by imaging a control object onto the detector. An iterative calibration procedure is used to determine the brightness distribution of the control object. Two control objects were examined-film and a video monitor. With both control objects, the performance of the optical random number generator approached that of pseudorandom number generators.
Simulation of physical processes and Monte Carlo solutions to numerical problems on digital computers require sources of random numbers that follow specified density functions. In our experiments, the spatial coordinates of detected photoevents are used as a fast source of true random numbers to solve numerical problems by the Monte Carlo method. The probability density function for the location of a photoevent on the detector surface is proportional to the irradiance. We have constructed an optical random number generator using a microchannel plate detector with a resistive anode. It can produce bivariate random deviates with any probability density and any correlation between the two variables. The numbers pass the standard tests for randomness and fit to the given distributions (chi-square, correlation, sequence tests). Nonuniform distributions can be obtained with no loss of speed by manipulating the irradiance distribution across the detector, e.g., by imaging a transparency onto it. In particular, we have produced uniformly distributed random numbers and normally distributed random numbers with various correlations between the variables. We have also used the optical random number generator to find approximate solutions to systems of large linear algebraic equations and approximations to the inverses of large matrices, with a maximum error of <5%.
Abstract Random numbers were generated using the probabilistic behavior of a single photon in an optical fiber coupler. An optical fiber coupler (1:1 split ratio) distributes with equal probability a single photon to two optical paths. Therefore, a binary random number sequence was obtained. This random number generation rate was 2.94 Mbit/s. We found from the results of examining the obtained random number sequence that correlation appears between adjacent numbers of random numbers because there is a dead‐time (Td=50ns) in the photon detector. Therefore, we created a new random number sequence by sampling every second random number. This random number sequence did pass statistical tests for independence and uniformity. Consequently, the random number generation rate was 1.47 Mbit/s. © 2006 Wiley Periodicals, Inc. Electron Comm Jpn Pt 3, 90(2): 1–8, 2007; Published online in Wiley InterScience ( www.interscience.wiley.com ). DOI 10.1002/ecjc.20229
An optical quantum random number generator based on parity of the number of photons detected in the equal time intervals was proposed. Light emitted from a continuous wave laser diode is attenuated into discrete single-photon sequence. The single photon is detected by a single-photon avalanche photodiode module. Random bit is extracted by measuring the parity of number of photons detected in equal time interval. The random bit extraction circuit based on field programmable gate array was developed. The influences of the size of time interval and the performance parameters of single photon module on performance of the designed random number generator were analyzed. In order to achieve a random bit generator with small deviation and fast generation rate, a method of setting time interval automatically according to average counting rate was proposed. A random bit generation rate of 2 Mbit/s was obtained when the designed random number generator works on a counting rate of 20 Mcps and the equal time interval is set as 0.5 μs. The random bit sequences were tested by random number test program ENT and STS. The test results show that the generated random bit sequences fully meet the standards of true random numbers, and do not require post-processin ©, 2015, Chinese Optical Society. All right reserved.
Imaging is the estimation of the spatial distribution of a physical object by measuring the optical radiation it emits, or by making use of an optical wave that interacts with the object, via reflection or transmission, for example, before being measured by a detector. The resolution of an imaging system is limited by the inability to localize the optical field at points of the object. Under otherwise ideal conditions, resolution is limited by diffraction. The sensitivity of an imaging system is limited by the uncertainty in the measurement. Under ideal conditions, this is determined by photon noise, which depends on the statistical fluctuations of the light. In conventional imaging systems, an extended detector, such as a CCD camera or an array detector, measures the spatial distribution of the optical intensity, which is proportional to the photon flux density. In interferometric systems, the spatial distribution of the optical field is inferred from measurements of the optical intensity. With the emergence of coherence theory, imaging systems based on measurements of the second-order coherence function at pairs of points in the detection plane were developed. An example is the imaging of an incoherent object based on the van Cittert-Zernike theorem. Imaging systems based on measurement of intensity correlation, or the photon coincidence rate, at pairs of points, were developed in the 1960s. A classic example of the photon-correlation imaging of an object emitting thermal light is stellar imaging using a Hanbury-Brown-Twiss intensity-correlation interferometer. More recently, two-photon light, which may be generated via spontaneous parametric downconversion in a second-order nonlinear optical crystal, has been used for imaging. This type of two-photon (or biphoton) imaging, which has come to be called quantum imaging, is also based on the measurement of photon coincidence by the use of photon-counting array detectors or by scanning two photon-counting detectors at pairs of points. To compare the resolution and sensitivity of imaging systems based on the aforementioned types of measurements, it is necessary to derive expressions for the measured quantities in terms of the object distribution. The point-spread functions based on such expressions can be used to assess the resolution. One measure of the sensitivity of the imaging process is the signal-to-noise ratio (SNR) of the measured variables. The statistical nature of the light source must be known in order to determine the SNR. The purpose of this chapter is to compare the resolution and sensitivity of photon-correlation imaging systems that make use of thermal light and two-photon light. We will henceforth refer to these two imaging modalities as classical and quantum photon-correlation imaging, or simply classical and quantum imaging, respectively. Clearly, light in other quantum states can also be used for imaging.
Random number generators include a thermal optical source and detector configured to produce random numbers based on quantum-optical intensity fluctuations. An optical flux is detected, and signals proportional to optical intensity and a delayed optical intensity are combined. The combined signals can be electrical signals or optical signals, and the optical source is selected so as to have low coherence over a predetermined range of delay times. Balanced optical detectors can be used to reduce common mode noise, and in some examples, the optical flux is directed to only one of a pair of balanced detectors.