Physical Review Letters

Miniaturized Wire Trap for Neutral Atoms

József Fortágh, Alexander Grossmann, Claus Zimmermann, Theodor W. Hänsch

Published Dec 14, 1998• 123 citations
Publisher

Abstract

We demonstrate the loading of a miniaturized magnetic guide for neutral atoms made of small-size current conductors. Cold rubidium atoms are initially stored in a shallow spherical quadrupole field and subsequently transferred into the magnetic guide by gradually transforming the trapping potential. Density, temperature, and atom number have been monitored in situ by absorption imaging with a charge-coupled device camera. A fraction of $14%$ of the initially trapped atoms has been transferred into the linear microtrap at a temperature of $39\ensuremath{\mu}\mathrm{K}$.

DOI
10.1103/physrevlett.81.5310

Related papers

Efficient loading of a magnetic waveguide on an atom chip

Peter D. D. Schwindt, Eric Cornell, T. Kishimoto +2 more

We demonstrate efficient loading of neutral atoms into a magnetic waveguide produced by the magnetic fields of microfabricated current-carrying conductors. The lithographically patterned conductors on this ``atom chip'' can be used to make a variety of guiding and trapping structures for manipulating cold atoms and Bose-Einstein condensates. A three-chamber vacuum apparatus collects atoms in a magneto-optical trap, precools them via evaporative cooling, and delivers them to the final chamber containing the atom chip. We describe in detail how the precooled atomic cloud is transferred from a macroscopic magnetic Ioffe-Pritchard trap to the microscopic magnetic waveguide on the atom chip $21\phantom{\rule{0.3em}{0ex}}\mathrm{cm}$ away. Permanent magnets provide a confining two-dimensional quadrupole field to guide the atoms between the two chambers while longitudinally the cloud is allowed to freely expand during the transfer. Strategically placed coils are used to control the longitudinal size and speed of the atomic cloud as it is loaded on the atom chip.

Physical Review A•Aug 18, 2005•13 citations

On loading of a magneto-optical trap on an atom-chip with U-wire quadrupole field

Vivek Singh, Vibhuti Bhushan Tiwari, K. A. P. Singh +1 more

The role of U-wire generated quadrupole-like magnetic field profile on loading of cold 87Rb atoms in a magneto-optical trap (MOT) on atom-chip has been investigated. It is shown by simulations that the quadrupole field profile and the centre of the quadrupole field vary depending upon the U-wire current and bias field values. Moreover, the resemblance of generated field profile to the ideal quadrupole field critically depends on the values of current in U-wire and bias magnetic field. The observed number of trapped atoms in the MOT and its position has also been found to depend on the quadrupole field profile. The number of trapped atoms in the MOT reaches maximum when the field profile approaches close to an ideal quadrupole field. These studies are, in general, useful in optimizing the number in the MOT before transfer of these cold atoms to the microtraps of an atom-chip.

arXiv:1801.09461•Journal of Modern Optics•Aug 21, 2018•12 citations

Direct loading of atoms from a macroscopic quadrupole magnetic trap into a microchip trap

Jun Jie Cheng, Jingfang Zhang, Xinping Xu +2 more

We demonstrate the direct loading of cold atoms into a microchip 2-mm Z-trap, where the evaporative cooling can be performed efficiently, from a macroscopic quadrupole magnetic trap with a high loading efficiency. The macroscopic quadrupole magnetic trap potential is designed to be moveable by controlling the currents of the two pairs of anti-Helmholtz coils. The cold atoms are initially prepared in a standard six-beam magneto-optical trap and loaded into the macroscopic quadrupole magnetic trap, and then transported to the atom chip surface by moving the macroscopic trap potential. By means of a three-dimensional absorption imaging system, we are able to optimize the position alignment of the atom cloud in the macroscopic trap and the microchip Z-shaped wire. Consequently, with a proper magnetic transfer scheme, we load the cold atoms into the microchip Z-trap directly and efficiently. The loading efficiency is measured to be about 50%. This approach can be used to generate appropriate ultracold atoms sources, for example, for a magnetically guided atom interferometer based on atom chip.

Chinese Physics B•Mar 1, 2017•2 citations

Magnetic Guide and Trap for Cold Neutral Atoms with Current‐Carrying Wires and Conductors

Jianping Yin, Weijian Gao, Nanchun Liu +2 more

Abstract We propose two novel schemes for guiding cold, neutral atoms using static magnetic fields generated by several cylindrical arrays of current‐carrying wires or a few different‐shaped (V‐, or U‐shaped, etc.) current‐carrying conductors, and calculate the corresponding magnetic‐field contours and their trapping potentials. Our study shows that some guiding schemes can be used to form an atomic funnel, or an atomic beam‐splitter, or even construct an atomic interferometer, and some guiding schemes can be used to realize a single‐mode wave guide of ultracold atoms (or coherent matter waves, BEC) under certain conditions. We also propose a few new schemes to microscopically trap neutral atoms by using various planar arrays of current‐carrying wires and calculate the spatial distribution of the magnetic fields. Our research shows that these microtrap arrays can be used to form 1D, 2D or 3D atomic magnetic lattices, and then to prepare 1D, 2D or 3D photonic crystals, even to realize a 1D, 2D or 3D array of magnetically‐trapped BECs or Bose Clusters.

Journal of the Chinese Chemical Society•Jun 1, 2001•2 citations

Atomic transport in integrated magnetic microtraps

W. Hänsel, J. Reischel, P. Hommerhoff +1 more

Summary form only given. Magnetic microtraps with current-carrying wires have initially been proposed in order to reach field configurations with high gradients. In our first demonstration of an electromagnetic microtrap, we used a lithography created wire on a substrate at room temperature to realize a quadrupole trap. Transverse gradients of 1600 G/cm were achieved with only 2A of current flowing, through the wire. More recently, we have extended this technique in Ioffe traps, which are more suitable for achieving long lifetimes at low temperatures. A moving chain of Ioffe-Pritchard traps can be created with a simple planar wire configuration. We present experimental results with this atom motor.

Conference on Lasers and Electro-Optics•Aug 29, 2005•0 citations

Atomic Micromanipulation with Magnetic Surface Traps

Jakob Reichel, W. Hänsel, Theodor W. Hänsch

We describe manipulation of neutral atoms using the magnetic field of microfabricated current-carrying conductors. It is shown how this method can be used to achieve adiabatic magnetic transport from one reservoir to another. In the first experimental realization of a microfabricated magnetic neutral-atom trap, efficient loading is achieved with a novel mirror-magneto-optic trap. A cloud of rubidium atoms is stored and compressed using the magnetic field of a ``U''-shaped wire carrying a current of 2 A. An evaporation mechanism is demonstrated which removes hot atoms from the trap by collisions with the substrate surface.

Physical Review Letters•Oct 25, 1999•415 citations
We demonstrate the loading of a miniaturized magnetic guide for neutral atoms made of small-size current conductors. Cold rubidium atoms are initially stored in a shallow spherical quadrupole field and subsequently transferred into the magnetic guide by gradually transforming the trapping potential. Density, temperature, and atom number have been monitored in situ by absorption imaging with a charge-coupled device camera. A fraction of 1414%14 of the initially trapped atoms has been transferred into the linear microtrap at a temperature of 39\ensuremathμK39\ensuremath{\mu}\mathrm{K}39\ensuremathμK.
We demonstrate efficient loading of neutral atoms into a magnetic waveguide produced by the magnetic fields of microfabricated current-carrying conductors. The lithographically patterned conductors on this ``atom chip'' can be used to make a variety of guiding and trapping structures for manipulating cold atoms and Bose-Einstein condensates. A three-chamber vacuum apparatus collects atoms in a magneto-optical trap, precools them via evaporative cooling, and delivers them to the final chamber containing the atom chip. We describe in detail how the precooled atomic cloud is transferred from a macroscopic magnetic Ioffe-Pritchard trap to the microscopic magnetic waveguide on the atom chip 21cm21\phantom{\rule{0.3em}{0ex}}\mathrm{cm}21cm away. Permanent magnets provide a confining two-dimensional quadrupole field to guide the atoms between the two chambers while longitudinally the cloud is allowed to freely expand during the transfer. Strategically placed coils are used to control the longitudinal size and speed of the atomic cloud as it is loaded on the atom chip.
The role of U-wire generated quadrupole-like magnetic field profile on loading of cold 87Rb atoms in a magneto-optical trap (MOT) on atom-chip has been investigated. It is shown by simulations that the quadrupole field profile and the centre of the quadrupole field vary depending upon the U-wire current and bias field values. Moreover, the resemblance of generated field profile to the ideal quadrupole field critically depends on the values of current in U-wire and bias magnetic field. The observed number of trapped atoms in the MOT and its position has also been found to depend on the quadrupole field profile. The number of trapped atoms in the MOT reaches maximum when the field profile approaches close to an ideal quadrupole field. These studies are, in general, useful in optimizing the number in the MOT before transfer of these cold atoms to the microtraps of an atom-chip.
We demonstrate the direct loading of cold atoms into a microchip 2-mm Z-trap, where the evaporative cooling can be performed efficiently, from a macroscopic quadrupole magnetic trap with a high loading efficiency. The macroscopic quadrupole magnetic trap potential is designed to be moveable by controlling the currents of the two pairs of anti-Helmholtz coils. The cold atoms are initially prepared in a standard six-beam magneto-optical trap and loaded into the macroscopic quadrupole magnetic trap, and then transported to the atom chip surface by moving the macroscopic trap potential. By means of a three-dimensional absorption imaging system, we are able to optimize the position alignment of the atom cloud in the macroscopic trap and the microchip Z-shaped wire. Consequently, with a proper magnetic transfer scheme, we load the cold atoms into the microchip Z-trap directly and efficiently. The loading efficiency is measured to be about 50%. This approach can be used to generate appropriate ultracold atoms sources, for example, for a magnetically guided atom interferometer based on atom chip.
Abstract We propose two novel schemes for guiding cold, neutral atoms using static magnetic fields generated by several cylindrical arrays of current‐carrying wires or a few different‐shaped (V‐, or U‐shaped, etc.) current‐carrying conductors, and calculate the corresponding magnetic‐field contours and their trapping potentials. Our study shows that some guiding schemes can be used to form an atomic funnel, or an atomic beam‐splitter, or even construct an atomic interferometer, and some guiding schemes can be used to realize a single‐mode wave guide of ultracold atoms (or coherent matter waves, BEC) under certain conditions. We also propose a few new schemes to microscopically trap neutral atoms by using various planar arrays of current‐carrying wires and calculate the spatial distribution of the magnetic fields. Our research shows that these microtrap arrays can be used to form 1D, 2D or 3D atomic magnetic lattices, and then to prepare 1D, 2D or 3D photonic crystals, even to realize a 1D, 2D or 3D array of magnetically‐trapped BECs or Bose Clusters.
Summary form only given. Magnetic microtraps with current-carrying wires have initially been proposed in order to reach field configurations with high gradients. In our first demonstration of an electromagnetic microtrap, we used a lithography created wire on a substrate at room temperature to realize a quadrupole trap. Transverse gradients of 1600 G/cm were achieved with only 2A of current flowing, through the wire. More recently, we have extended this technique in Ioffe traps, which are more suitable for achieving long lifetimes at low temperatures. A moving chain of Ioffe-Pritchard traps can be created with a simple planar wire configuration. We present experimental results with this atom motor.
We describe manipulation of neutral atoms using the magnetic field of microfabricated current-carrying conductors. It is shown how this method can be used to achieve adiabatic magnetic transport from one reservoir to another. In the first experimental realization of a microfabricated magnetic neutral-atom trap, efficient loading is achieved with a novel mirror-magneto-optic trap. A cloud of rubidium atoms is stored and compressed using the magnetic field of a ``U''-shaped wire carrying a current of 2 A. An evaporation mechanism is demonstrated which removes hot atoms from the trap by collisions with the substrate surface.