Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review C

Storage of ultracold neutrons in a volume coated with diamondlike carbon

F. Atchison, B. Blau, M. Daum, P. Fierlinger, Peter W. Geltenbort, Reinhold Henneck, S. Heule, M. Kasprzak, K. Kirch, K. Kohlik, M. Kuźniak, M. Meier, Carl‐Friedrich Meyer, A. Pichlmaier, C. Plonka, P. Schmidt-Wellenburg, Bernd Schultrich, Th. Stucky, Volker Weihnacht, O. Zimmer

Published Nov 9, 2006• 30 citations
Publisher

Abstract

Ultracold neutrons (UCN) with energy up to the Fermi potential were stored for the first time in a volume coated with diamondlike carbon. As a function of the UCN energy and wall temperature of the storage volume, we measured the wall loss parameter \ensuremath{\eta} and obtained $\ensuremath{\eta}=(3.1\ifmmode\pm\else\textpm\fi{}0.9)\ifmmode\cdot\else\textperiodcentered\fi{}{10}^{\ensuremath{-}4}$ at $T=290$ K and $\ensuremath{\eta}=(1.8\ifmmode\pm\else\textpm\fi{}0.2)\ifmmode\cdot\else\textperiodcentered\fi{}{10}^{\ensuremath{-}4}$ at $T=115$ K.

DOI
10.1103/physrevc.74.055501

Related papers

Loss and spinflip probabilities for ultracold neutrons interacting with diamondlike carbon and beryllium surfaces

F. Atchison, Tomasz Bryś, M. Daum +11 more

The storage of ultracold neutrons (UCN) in a combined magnetic, gravitational, and material trap is described. Wall materials investigated were diamondlike carbon (DLC) coatings on solid and flexible foil substrates as well as beryllium coatings on solid substrates. The loss coefficient per wall collision, \ensuremath{\eta}, and the depolarization probability \ensuremath{\beta} were measured simultaneously as a function of temperature (from 70 to 400 K) and energy (from 30 to 80 neV). The results at 70 K are $\ensuremath{\eta}=(0.7\ifmmode\pm\else\textpm\fi{}0.1)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}4},\ensuremath{\beta}=(15.4\ifmmode\pm\else\textpm\fi{}1.0)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}6}$ for DLC on polyethyleneterephtalate (PET) foil and $\ensuremath{\eta}=(1.7\ifmmode\pm\else\textpm\fi{}0.1)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}4},\ensuremath{\beta}=(0.7\ifmmode\pm\else\textpm\fi{}0.3)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}6}$ for DLC on aluminum foil. At room temperature the loss coefficients are larger by a factor of about 2 whereas the depolarization probabilities are found to be independent of temperature. The corresponding values for Be at room temperature are $\ensuremath{\eta}~5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}4},\ensuremath{\beta}~10\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}6}$. The DLC results for \ensuremath{\beta} and for the temperature-dependent part of the loss coefficient, ${\ensuremath{\eta}}_{T}$, are interpreted in terms of incoherent scattering by hydrogen. The hydrogen admixture was measured independently by elastic recoil detection analysis to be about $1\ifmmode\times\else\texttimes\fi{}{10}^{16}$ atoms/cm${}^{2}$. The data do not support the hypothesis of hydrogen being chemically bound within the top layers of the DLC. Using two different models with a thin waterlike film on top of the substrate we obtain consistency between the temperature-dependent loss contribution and the measured hydrogen contamination.

Physical Review C•Oct 4, 2007•34 citations

First ever storage of ultracold neutrons in a magnetic trap made of permanent magnets

В. Ф. Ежов, A. Z. Andreev, A.A. Glushkov +13 more

Further improvement in the accuracy of any neutron lifetime experiment by means of ultracold neutrons (UCN) in material bottles is limited due to unavoidable systematic effects when the UCN are reflected from the walls. However, such effects can be excluded in principle if magnetic trapping of UCN is used. The storage of UCN in a small magnetic trap made of permanent magnets was demonstrated for the first time ever. The measured storage time in this feasibility study was (882 ± 16) s. At this level of accuracy no depolarization was observed.

Journal of Research of the National Institute of Standards and Technology•Jul 1, 2005•23 citations

A new escape channel for ultracold neutrons in traps

Peter W. Geltenbort, V. V. Nesvizhevsky, D. G. Kartashov +9 more

A surprising new escape channel for ultracold neutrons (UCNs) in traps was reported recently. It could be relevant to the long-standing puzzle of the “too high” loss rate of UCNs from traps, which has yet to be completely understood and eliminated. In the present work we positively identify the new phenomenon and investigate it in detail. The escape of UCNs from traps is due to rare events in which their energy undergoes a small increase (∼10 −7 eV). The reason for such an energy gain and its impact on the physics of UCN storage is still to be investigated.

Journal of Experimental and Theoretical Physics Letters•Aug 1, 1999•9 citations

Neutron Optical Experiments Probing the Wave Properties of Ultracold Neutrons

The neutron is the only massive elementary particle that can be produced with kinetic energies E so low that the corresponding de Broglie wavelengths λ = 2 π ℏ / 2 m n E reach macroscopic dimensions of the order of micrometers. It has, therefore, been obvious from the beginning of the “UCN era” that they could be used as a tool to probe wave mechanics in a region of long particle waves which had previously been inaccessible. Add to this the fact that many years of UCN history were haunted by the so-called “UCN storage anomaly”: The measured survival time of UCNs in bottles made of many different materials always fell way short of the expectation based on the known loss cross-sections for the wall material. Could UCN optics lead the way to a better understanding?

WORLD SCIENTIFIC eBooks•May 29, 2020•0 citations

Neutrons on a surface of liquid helium

P. D. Grigoriev, O. Zimmer, A. D. Grigoriev +1 more

We investigate the possibility of ultracold neutron (UCN) storage in quantum states defined by the combined potentials of the Earth's gravity and the neutron optical repulsion by a horizontal surface of liquid helium. We analyze the stability of the lowest quantum state, which is most susceptible to perturbations due to surface excitations, against scattering by helium atoms in the vapor and by excitations of the liquid, comprised of ripplons, phonons, and surfons. This is an unusual scattering problem since the kinetic energy of the neutron parallel to the surface may be much greater than the binding energies perpendicular. The total scattering time of these UCNs at $0.7$ K is found to exceed 1 h, and rapidly increases with decreasing temperature. Such low scattering rates should enable high-precision measurements of the sequence of discrete energy levels, thus providing improved tests of short-range gravity. The system might also be useful for neutron $\ensuremath{\beta}$-decay experiments. We also sketch new experimental propositions for level population and trapping of ultracold neutrons above a flat horizontal mirror.

arXiv:1509.06343•Physical Review C•Aug 22, 2016•8 citations

Comment to the article "Temperature dependence of ultracold neutron loss rates" E.Korobkina et al., PRB 70,035409

Anatolii P. Serebrov

In work [1] ("Temperature dependence of ultracold neutron loss rates" E.Korobkina et al., PRB 70,035409) results of measurement of temperature dependence of losses of ultracold neutrons (UCN) in a range from 4 K to 300 K at UCN storage in a copper trap are presented. At interpretation of experimental data it was artificially considered only the difference of losses rate 1/tau(T)= 1/tau_exp(T)- 1/tau_exp(10K), (tau - UCN storage time in the trap). It has been accepted for temperature dependence of losses which changes from 0 to 3.3*10-4 per one collision of UCN with a trap surface. However, the analysis of raw experimental data shows that in a trap at temperature 10 K there is losses 1.0*10-3 per collision. They are considerably (in 3 times) more than discussed temperature dependence and almost 10 times more than losses due to capture cross section on copper. It is the most probable that these losses are connected with leakage of UCN through a slit of trap shutter. Change of the size of a slits on 25% at change of temperature from 300K to 10K can quite explain discussed temperature dependence. Certainly, hydrogen is present on a surface, but as it was shown at work [2] (V.P.Alfimenkov et al., JETP., Vol. 55, No. 2 25 Jan.1992) temperature dependence in 3 times lower, even on the undegased surfaces than on the degassed and deuterated surface in work [1]. At last, deuteration of a trap surface allows almost completely to suppress temperature dependence connected with presence of hydrogen [2]. The conclusion of work [1] is that hydrogen is localized on a surface in the form of a film, instead of distribution in the surface substance. This conclusion contradicts results of measurement of energy dependence of UCN losses in work [2]. More detailed analysis of work [1] and works [2] is presented below.

arXiv:0905.0803•May 6, 2009•0 citations
Ultracold neutrons (UCN) with energy up to the Fermi potential were stored for the first time in a volume coated with diamondlike carbon. As a function of the UCN energy and wall temperature of the storage volume, we measured the wall loss parameter \ensuremath{\eta} and obtained \ensuremathη=(3.1\ifmmode±\else\textpm\fi0.9)\ifmmode⋅\else\textperiodcentered\fi10\ensuremath−4\ensuremath{\eta}=(3.1\ifmmode\pm\else\textpm\fi{}0.9)\ifmmode\cdot\else\textperiodcentered\fi{}{10}^{\ensuremath{-}4}\ensuremathη=(3.1\ifmmode±\else\textpm\fi0.9)\ifmmode⋅\else\textperiodcentered\fi10\ensuremath−4 at T=290T=290T=290 K and \ensuremathη=(1.8\ifmmode±\else\textpm\fi0.2)\ifmmode⋅\else\textperiodcentered\fi10\ensuremath−4\ensuremath{\eta}=(1.8\ifmmode\pm\else\textpm\fi{}0.2)\ifmmode\cdot\else\textperiodcentered\fi{}{10}^{\ensuremath{-}4}\ensuremathη=(1.8\ifmmode±\else\textpm\fi0.2)\ifmmode⋅\else\textperiodcentered\fi10\ensuremath−4 at T=115T=115T=115 K.
The storage of ultracold neutrons (UCN) in a combined magnetic, gravitational, and material trap is described. Wall materials investigated were diamondlike carbon (DLC) coatings on solid and flexible foil substrates as well as beryllium coatings on solid substrates. The loss coefficient per wall collision, \ensuremath{\eta}, and the depolarization probability \ensuremath{\beta} were measured simultaneously as a function of temperature (from 70 to 400 K) and energy (from 30 to 80 neV). The results at 70 K are $\ensuremath{\eta}=(0.7\ifmmode\pm\else\textpm\fi{}0.1)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}4},\ensuremath{\beta}=(15.4\ifmmode\pm\else\textpm\fi{}1.0)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}6}$ for DLC on polyethyleneterephtalate (PET) foil and $\ensuremath{\eta}=(1.7\ifmmode\pm\else\textpm\fi{}0.1)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}4},\ensuremath{\beta}=(0.7\ifmmode\pm\else\textpm\fi{}0.3)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}6}$ for DLC on aluminum foil. At room temperature the loss coefficients are larger by a factor of about 2 whereas the depolarization probabilities are found to be independent of temperature. The corresponding values for Be at room temperature are $\ensuremath{\eta}~5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}4},\ensuremath{\beta}~10\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}6}$. The DLC results for \ensuremath{\beta} and for the temperature-dependent part of the loss coefficient, ${\ensuremath{\eta}}_{T}$, are interpreted in terms of incoherent scattering by hydrogen. The hydrogen admixture was measured independently by elastic recoil detection analysis to be about $1\ifmmode\times\else\texttimes\fi{}{10}^{16}$ atoms/cm2{}^{2}2. The data do not support the hypothesis of hydrogen being chemically bound within the top layers of the DLC. Using two different models with a thin waterlike film on top of the substrate we obtain consistency between the temperature-dependent loss contribution and the measured hydrogen contamination.
Further improvement in the accuracy of any neutron lifetime experiment by means of ultracold neutrons (UCN) in material bottles is limited due to unavoidable systematic effects when the UCN are reflected from the walls. However, such effects can be excluded in principle if magnetic trapping of UCN is used. The storage of UCN in a small magnetic trap made of permanent magnets was demonstrated for the first time ever. The measured storage time in this feasibility study was (882 ± 16) s. At this level of accuracy no depolarization was observed.
A surprising new escape channel for ultracold neutrons (UCNs) in traps was reported recently. It could be relevant to the long-standing puzzle of the “too high” loss rate of UCNs from traps, which has yet to be completely understood and eliminated. In the present work we positively identify the new phenomenon and investigate it in detail. The escape of UCNs from traps is due to rare events in which their energy undergoes a small increase (∼10 −7 eV). The reason for such an energy gain and its impact on the physics of UCN storage is still to be investigated.
The neutron is the only massive elementary particle that can be produced with kinetic energies E so low that the corresponding de Broglie wavelengths λ = 2 π ℏ / 2 m n E reach macroscopic dimensions of the order of micrometers. It has, therefore, been obvious from the beginning of the “UCN era” that they could be used as a tool to probe wave mechanics in a region of long particle waves which had previously been inaccessible. Add to this the fact that many years of UCN history were haunted by the so-called “UCN storage anomaly”: The measured survival time of UCNs in bottles made of many different materials always fell way short of the expectation based on the known loss cross-sections for the wall material. Could UCN optics lead the way to a better understanding?
We investigate the possibility of ultracold neutron (UCN) storage in quantum states defined by the combined potentials of the Earth's gravity and the neutron optical repulsion by a horizontal surface of liquid helium. We analyze the stability of the lowest quantum state, which is most susceptible to perturbations due to surface excitations, against scattering by helium atoms in the vapor and by excitations of the liquid, comprised of ripplons, phonons, and surfons. This is an unusual scattering problem since the kinetic energy of the neutron parallel to the surface may be much greater than the binding energies perpendicular. The total scattering time of these UCNs at 0.70.70.7 K is found to exceed 1 h, and rapidly increases with decreasing temperature. Such low scattering rates should enable high-precision measurements of the sequence of discrete energy levels, thus providing improved tests of short-range gravity. The system might also be useful for neutron $\ensuremath{\beta}$-decay experiments. We also sketch new experimental propositions for level population and trapping of ultracold neutrons above a flat horizontal mirror.
In work [1] ("Temperature dependence of ultracold neutron loss rates" E.Korobkina et al., PRB 70,035409) results of measurement of temperature dependence of losses of ultracold neutrons (UCN) in a range from 4 K to 300 K at UCN storage in a copper trap are presented. At interpretation of experimental data it was artificially considered only the difference of losses rate 1/tau(T)= 1/tau_exp(T)- 1/tau_exp(10K), (tau - UCN storage time in the trap). It has been accepted for temperature dependence of losses which changes from 0 to 3.3*10-4 per one collision of UCN with a trap surface. However, the analysis of raw experimental data shows that in a trap at temperature 10 K there is losses 1.0*10-3 per collision. They are considerably (in 3 times) more than discussed temperature dependence and almost 10 times more than losses due to capture cross section on copper. It is the most probable that these losses are connected with leakage of UCN through a slit of trap shutter. Change of the size of a slits on 25% at change of temperature from 300K to 10K can quite explain discussed temperature dependence. Certainly, hydrogen is present on a surface, but as it was shown at work [2] (V.P.Alfimenkov et al., JETP., Vol. 55, No. 2 25 Jan.1992) temperature dependence in 3 times lower, even on the undegased surfaces than on the degassed and deuterated surface in work [1]. At last, deuteration of a trap surface allows almost completely to suppress temperature dependence connected with presence of hydrogen [2]. The conclusion of work [1] is that hydrogen is localized on a surface in the form of a film, instead of distribution in the surface substance. This conclusion contradicts results of measurement of energy dependence of UCN losses in work [2]. More detailed analysis of work [1] and works [2] is presented below.