I will introduce chirped-pulse interferometry and show how it can be applied to dispersion-cancelled optical coherence tomography. I will describe our recent results using chirped laser and single-photon pulses for compression of single photon spectra.
Quantum information science promises transformative impact over a range of key technologies in computing, communication, and sensing. A prominent example uses entangled photons to overcome the resolution-degrading effects of dispersion in the medical-imaging technology, optical coherence tomography. The quantum solution introduces new challenges: inherently low signal and artifacts, additional unwanted signal features. It has recently been shown that entanglement is not a requirement for automatic dispersion cancellation. Such classical techniques could solve the low-signal problem, however they all still suffer from artifacts. Here, we introduce a method of chirped-pulse interferometry based on shaped laser pulses, and use it to produce artifact-free, high-resolution, dispersion-cancelled images of the internal structure of a biological sample. Our work fulfills one of the promises of quantum technologies: automatic-dispersion-cancellation interferometry in biomedical imaging. It also shows how subtle differences between a quantum technique and its classical analogue may have unforeseen, yet beneficial, consequences.
Interference has long been used for precision measurement of path-length changes. Since the advent of the laser, interference has become one of the most versatile tools in metrology. Specifically, ultra-short laser pulses allow unprecedented resolution in absolute length measurements. While ultra-short laser pulses lead to high resolution, for example in white-light interferometry, they are very susceptible to dispersion. \n \nQuantum resources have been proposed to overcome some of the problems related to distortions in the interferometric signal. For example, the Hong-Ou-Mandel (HOM) interferometer relies on frequency-entangled photon pairs and features automatic even-order dispersion cancellation and high interference visibility resilient to unbalanced loss. Quantum-OCT is a technique based on HOM interferometry, that promises to overcome Optical Coherence Tomography (OCT) a classical imaging technique based on low coherence light. Furthermore, straightforward modifications of the HOM interferometer can display several different interferometric signals, including the HOM peak, quantum beating, and phase super-resolution. However, the quantum resources required are hard to produce and dim, leading to long integration times and single-photon counting. \n \nIn this thesis, we introduce the theory behind Chirped-Pulse Interferometry (CPI), a new technique that combines all the advantages of Q-OCT, including even-order dispersion cancellation, but without the need for any quantum resources. We then experimentally implement CPI and demonstrate all the important characteristics shared by the HOM interferometer, but at dramatically larger signal levels. We show how CPI can be used to measure dispersion cancelled axial profiles of an optical sample and show the improvement in resolution over white-light interferometry. Finally, we show that by modifying CPI in analogous ways to HOM, CPI can also be made to produce interferometric signal identical to the HOM peak, quantum beating, and phase super-resolution.
Chirped-pulse interferometry is a new interferometric technique encapsulating the advantages of the quantum Hong-Ou-Mandel interferometer without the drawbacks of using entangled photons. Both interferometers can exhibit even-order dispersion cancellation which allows high resolution optical delay measurements even in thick optical samples. In the present work, we show that finite frequency correlations in chirped-pulse interferometry and Hong-Ou-Mandel interferometry limit the degree of dispersion cancellation. Our results are important considerations in designing practical devices based on these technologies.
Here we report on a completely classical technique based on the time-reversal symmetry of quantum mechanics that achieves all the advantages of HOM interferometry by using oppositely-chirped laser pulses. Since our technique relies on classical lasers instead of entangled photons, it achieves these features with millions of times larger signal making it an attractive candidate for dispersion-free OCT. In particular, the visibility and width of the CPI interferogram is insensitive to dispersion and photon loss, and inherently robust against phase-fluctuations. Further, we achieve higher resolution than classical interferometers using the same bandwidth. On a fundamental level, our work emphasizes the importance of delineating truly quantum effects from those with classical analogues, and shows how insights gained from quantum mechanics can inspire novel classical technologies.
Quantum-optical coherence tomography (Q-OCT) is an interferometric technique for axial imaging offering several advantages over conventional methods. Chirped-pulse interferometry (CPI) was recently demonstrated to exhibit all of the benefits of the quantum interferometer upon which Q-OCT is based. Here we use CPI to measure axial interferograms to profile a sample accruing the important benefits of Q-OCT, including automatic dispersion cancellation, but with 10 million times higher signal. Our technique solves the artifact problem in Q-OCT and highlights the power of classical correlation in optical imaging.