Conference on Lasers and Electro-Optics

Continuous-Variable Measurement-Device-Independent Quantum Key Distribution with Imperfect Detectors

Zhengyu Li, Xiang Peng, Hong Mei Guo

Published Jan 1, 2014• 3 citations
Publisher

Abstract

We show that the performance of continuous-variable measurement-device-independent quantum key distribution will decline dramatically when considering detector’s imperfections. However, it can be improved by using phase sensitive optical amplifiers.
DOI
10.1364/cleo_qels.2014.fm4a.2

Related papers

Unidimensional continuous-variable quantum key distribution with imperfect detector

Yichen Zhang, Luyu Huang, Song Yu +1 more

We report a method to improve the performance of unidimensional continuous-variable quantum key distribution with imperfect detector by adding a parameter-adjustable optical amplifier, where the optimal performance can approach the scenario with a perfect detector.

•Dec 30, 2019•0 citations

Continuous variable measurement-device-independent quantum key distribution based on photon subtraction and optical amplifiers

Yi‐Hua Zhou, Shu-Fen Qin, Wei‐Min Shi +1 more

Optik•May 25, 2021•6 citations

Security of continuous-variable measurement-device-independent quantum key distribution with imperfect state preparation

Hongxin Ma, Peng Huang, Tao Wang +3 more

Physics Letters A•Sep 26, 2019•13 citations

Discrete-phase-randomized measurement-device-independent quantum key distribution

Zhu Cao

Measurement-device-independent quantum key distribution removes all detector-side attacks in quantum cryptography, and in the meantime doubles the secure distance. The source side, however, is still vulnerable to various attacks. In particular, the continuous phase randomization assumption on the source side is normally not fulfilled in experimental implementation and may potentially open a loophole. In this work, we first show that indeed there are loopholes for imperfect phase randomization in measurement-device-independent quantum key distribution by providing a concrete attack. Then we propose a discrete-phase-randomized measurement-device-independent quantum key distribution protocol as a solution to close this source-side loophole.

arXiv:2006.11983•Physical Review A•Jun 19, 2020•12 citations

Continuous-variable measurement-device-independent quantum key distribution using modulated squeezed states and optical amplifiers

Pu Wang, Xuyang Wang, Yongmin Li

The measurement-device-independent quantum key distribution (MDI-QKD) protocol is immune to imperfect measurement devices. However, its practicality and performance when implemented in continuous-variable (CV) mode are still not satisfactory. We propose a CV-MDI-QKD protocol based on modulated squeezed states, and analyze its security against two-mode Gaussian attack. The results show that the protocol can achieve a higher secret key rate and transmission distance than previous coherent-state and squeezed-state protocols. A method to compensate the imperfection of a practical homodyne detector using phase-sensitive optical amplifiers is also presented. By setting an appropriate optical amplification gain, realistic detectors with ordinary quantum efficiency can be employed. In addition, we discuss the impact of finite-size effects on the secret key rate of the protocol. The methods presented may aid in the practical application of the CV-MDI-QKD protocol.

Physical Review A•Apr 3, 2019•35 citations

Improvement of unidimensional continuous-variable quantum key distribution systems by using a phase-sensitive amplifier

Luyu Huang, Yichen Zhang, Yundi Huang +2 more

Abstract Inherent defects of the detectors in a practical system cause deterioration of the performance of the unidimensional coherent-state continuous-variable quantum key distribution protocol. Aiming to achieve optimal performance, we propose a method of using a phase-sensitive amplifier to overcome the limitation that the detectors introduce. The modified protocol, corresponding to a higher key rate, provides the practical system with more robustness. To conduct a thorough investigation into the effects that the phase-sensitive amplifier creates, the expressions of the secret key rates are derived, under the conditions of coherent states, homodyne detection against collective attacks, and a phase-sensitive optical amplifier added at the output of the channel. Then, we carry out simulations to observe the performance in the cases of different gains. The simulation results demonstrate that the method we propose can improve the performance of the unidimensional protocol using coherent states and make up for the imperfections of the detector in a practical system.

Journal of Physics B Atomic Molecular and Optical Physics•Sep 23, 2019•10 citations
Measurement-device-independent quantum key distribution removes all detector-side attacks in quantum cryptography, and in the meantime doubles the secure distance. The source side, however, is still vulnerable to various attacks. In particular, the continuous phase randomization assumption on the source side is normally not fulfilled in experimental implementation and may potentially open a loophole. In this work, we first show that indeed there are loopholes for imperfect phase randomization in measurement-device-independent quantum key distribution by providing a concrete attack. Then we propose a discrete-phase-randomized measurement-device-independent quantum key distribution protocol as a solution to close this source-side loophole.
The measurement-device-independent quantum key distribution (MDI-QKD) protocol is immune to imperfect measurement devices. However, its practicality and performance when implemented in continuous-variable (CV) mode are still not satisfactory. We propose a CV-MDI-QKD protocol based on modulated squeezed states, and analyze its security against two-mode Gaussian attack. The results show that the protocol can achieve a higher secret key rate and transmission distance than previous coherent-state and squeezed-state protocols. A method to compensate the imperfection of a practical homodyne detector using phase-sensitive optical amplifiers is also presented. By setting an appropriate optical amplification gain, realistic detectors with ordinary quantum efficiency can be employed. In addition, we discuss the impact of finite-size effects on the secret key rate of the protocol. The methods presented may aid in the practical application of the CV-MDI-QKD protocol.
Abstract Inherent defects of the detectors in a practical system cause deterioration of the performance of the unidimensional coherent-state continuous-variable quantum key distribution protocol. Aiming to achieve optimal performance, we propose a method of using a phase-sensitive amplifier to overcome the limitation that the detectors introduce. The modified protocol, corresponding to a higher key rate, provides the practical system with more robustness. To conduct a thorough investigation into the effects that the phase-sensitive amplifier creates, the expressions of the secret key rates are derived, under the conditions of coherent states, homodyne detection against collective attacks, and a phase-sensitive optical amplifier added at the output of the channel. Then, we carry out simulations to observe the performance in the cases of different gains. The simulation results demonstrate that the method we propose can improve the performance of the unidimensional protocol using coherent states and make up for the imperfections of the detector in a practical system.