Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Phase shifts in precision atom interferometry due to the localization of atoms and optical fields

Andreas Wicht, Edina Sarajlic, Joel M. Hensley, Steven Chu

Published Aug 1, 2005• 29 citations
Publisher

Abstract

We discuss details of momentum transfer in the interaction between localized atoms and localized optical fields which are relevant to precision atom interferometry. Specifically, we consider a $\ensuremath{\Lambda}$-type atom coherently driven between its ground states by a bichromatic optical field. We assume that the excited state can be eliminated adiabatically from the time evolution. It is shown that the average recoil momentum is given by the phase gradient of the two-photon field at the ``position'' of the atom, provided that the optical field can be described by a function which is separable in position and time and that the atomic wave function is symmetric and well localized within the optical field envelope. The result does not require the optical fields to have a Gaussian spatial dependence. Our discussion provides the basis for the analysis of systematic errors in precision atom interferometry arising from optical wave-front curvature, wave-front distortion, and the Gouy phase shift of Gaussian beams. We apply our result to the atom interferometer experiment of Chu and co-workers which measures the fine-structure constant.

DOI
10.1103/physreva.72.023602

Related papers

Transverse Confinement of Photon Position in the Light-Atom Interaction

Jun Ying Sun, Yong-Nan Sun

In an atom interferometry experiment, the output phase shift depends on the wave vector of photons and the recoil momentum in optical transitions. This Letter puts forward a hypothesis that in light-atom interaction, the atom wave function could provide a transverse confinement to photons and thus could affect the mean recoil momentum. We propose a model to analyze the photon effective wave vector in a monochromatic optical field and calculate the relative shift of |k[over →]_{eff}| to k when an atom with a 3D Gaussian wave function absorbs one photon in a Gaussian beam. This shift could lead to a systematic effect related to the spatial distribution of atoms and the transverse beam profile in high-precision experiments based on atom interferometry.

arXiv:1811.06731•Physical Review Letters•May 26, 2021•0 citations

Precision atom interferometry

Achim Peters, Keng Yeow Chung, Brent C. Young +2 more

The basic physical principles behind atom interferometers based on optical pulses of light are summarized. This method of atom interferometry is based on measurements in the time and frequency domain and is an inherently precise measurement technique. After a brief discussion of some of the important technical requirements for good fringe accuracy and visibility, we describe an interferometer that has measured the acceleration of an atom due to gravity with a resolution better than one part in 1010. We project that the absolute accuracy of our measurement will be of the order of a few parts in 109. We also describe an interferometer experiment that measures the recoil energy shift of an atom when it absorbs a photon. When combined with the value of the Rydberg constant and the mass ratios MCs/mp and mp/me, one can obtain a value for α, the fine structure constant. Currently, we have an experimental resolution Δα/α ∼ 10-8 after two hours of integration time and are studying the systematic effects that affect the measurement.

Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences•Dec 15, 1997•80 citations

Local measurement scheme of gravitational curvature using atom interferometers

Michael Werner, Ali Lezeik, Dennis Schlippert +3 more

Abstract Light pulse atom interferometers (AIFs) are exquisite quantum probes of spatial inhomogeneity and gravitational curvature. Moreover, detailed measurement and calibration are necessary prerequisites for very-long-baseline atom interferometry (VLBAI). Here we provide a theoretical analysis of the phase resulting in a complex gravitational environment and introduce a novel interferometer geometry which singles out the phase shift proportional to the curvature of the gravitational potential. The scale factor depends only on well controlled quantities, namely the photon wave number, the interferometer time and the atomic recoil, which allows the curvature to be accurately inferred from a measured phase. As a case study, we numerically simulate such a gradiometric interferometer in the context of the Hannover VLBAI facility and prove the robustness of the phase shift in gravitational fields with complex spatial dependence. We define an estimator of the gravitational curvature for non-trivial gravitational fields and calculate the trade-off between signal strength and estimation accuracy with regard to spatial resolution. As a perspective, we discuss the case of a time-dependent gravitational field and corresponding measurement strategies.

arXiv:2409.03515•Communications Physics•Nov 14, 2025•3 citations

Single-photon large-momentum-transfer atom interferometry scheme for Sr or Yb atoms with application to determining the fine-structure constant

J. Schelfhout, T. M. Hird, Kenneth M. Hughes +1 more

The leading experimental determinations of the fine-structure constant α currently rely on atomic photon-recoil measurements from Ramsey-Bordé atom interferometry with large-momentum transfer to provide an absolute mass measurement. We propose an experimental scheme for an intermediate-scale differential atom interferometer to measure the photon recoil of neutral atomic species with a single-photon optical clock transition. We calculate trajectories for our scheme that optimize the recoil phase while nullifying the undesired gravity-gradient phase by considering independently launching two clouds of ultracold atoms with the appropriate initial conditions. For Sr and Yb, we find an atom interferometer of height 3 m to be sufficient for an absolute mass measurement precision of Δ m / m ∼ 1 × 10 − 11 with current technology. Such a precise measurement would halve the current uncertainty in α , an uncertainty that would no longer be limited by an absolute mass measurement. The removal of this limitation would allow the current uncertainty in α to be reduced by a factor of 10 by corresponding improvements in relative mass measurements, thus paving the way for higher-precision tests of the standard model of particle physics. Published by the American Physical Society 2024

arXiv:2403.10225•Physical Review A•Nov 12, 2024•10 citations

Local photon momentum in an arbitrary monochromatic optical field

Jun Sun, Yong-Nan Sun

This work proposed a theory model for the local photon momentum in a monochromatic optical field. We analysed the transfered momentum when an atom absorbs a photon. Based on the uncertainty principle and Fourier optics theory, we claimed that the atom localization will confine the wavefunction of the absorbed photon that will effect the transfered momentum. We applied our theory to study the systematic effect in the metrology experiment for the fine structure constant based on atom interferometry.

•Nov 16, 2018•0 citations

Canceling the Gravity Gradient Phase Shift in Atom Interferometry

Giulio D'Amico, G. Rosi, S. Zhan +3 more

Gravity gradients represent a major obstacle in high-precision measurements by atom interferometry. Controlling their effects to the required stability and accuracy imposes very stringent requirements on the relative positioning of freely falling atomic clouds, as in the case of precise tests of Einstein's equivalence principle. We demonstrate a new method to exactly compensate the effects introduced by gravity gradients in a Raman-pulse atom interferometer. By shifting the frequency of the Raman lasers during the central π pulse, it is possible to cancel the initial position- and velocity-dependent phase shift produced by gravity gradients. We apply this technique to simultaneous interferometers positioned along the vertical direction and demonstrate a new method for measuring local gravity gradients that does not require precise knowledge of the relative position between the atomic clouds. Based on this method, we also propose an improved scheme to determine the Newtonian gravitational constant G towards the 10 ppm relative uncertainty.

Physical Review Letters•Dec 19, 2017•81 citations
We discuss details of momentum transfer in the interaction between localized atoms and localized optical fields which are relevant to precision atom interferometry. Specifically, we consider a \ensuremathΛ\ensuremath{\Lambda}\ensuremathΛ-type atom coherently driven between its ground states by a bichromatic optical field. We assume that the excited state can be eliminated adiabatically from the time evolution. It is shown that the average recoil momentum is given by the phase gradient of the two-photon field at the ``position'' of the atom, provided that the optical field can be described by a function which is separable in position and time and that the atomic wave function is symmetric and well localized within the optical field envelope. The result does not require the optical fields to have a Gaussian spatial dependence. Our discussion provides the basis for the analysis of systematic errors in precision atom interferometry arising from optical wave-front curvature, wave-front distortion, and the Gouy phase shift of Gaussian beams. We apply our result to the atom interferometer experiment of Chu and co-workers which measures the fine-structure constant.
In an atom interferometry experiment, the output phase shift depends on the wave vector of photons and the recoil momentum in optical transitions. This Letter puts forward a hypothesis that in light-atom interaction, the atom wave function could provide a transverse confinement to photons and thus could affect the mean recoil momentum. We propose a model to analyze the photon effective wave vector in a monochromatic optical field and calculate the relative shift of |k[over →]_{eff}| to k when an atom with a 3D Gaussian wave function absorbs one photon in a Gaussian beam. This shift could lead to a systematic effect related to the spatial distribution of atoms and the transverse beam profile in high-precision experiments based on atom interferometry.
The basic physical principles behind atom interferometers based on optical pulses of light are summarized. This method of atom interferometry is based on measurements in the time and frequency domain and is an inherently precise measurement technique. After a brief discussion of some of the important technical requirements for good fringe accuracy and visibility, we describe an interferometer that has measured the acceleration of an atom due to gravity with a resolution better than one part in 1010. We project that the absolute accuracy of our measurement will be of the order of a few parts in 109. We also describe an interferometer experiment that measures the recoil energy shift of an atom when it absorbs a photon. When combined with the value of the Rydberg constant and the mass ratios MCs/mp and mp/me, one can obtain a value for α, the fine structure constant. Currently, we have an experimental resolution Δα/α ∼ 10-8 after two hours of integration time and are studying the systematic effects that affect the measurement.
Abstract Light pulse atom interferometers (AIFs) are exquisite quantum probes of spatial inhomogeneity and gravitational curvature. Moreover, detailed measurement and calibration are necessary prerequisites for very-long-baseline atom interferometry (VLBAI). Here we provide a theoretical analysis of the phase resulting in a complex gravitational environment and introduce a novel interferometer geometry which singles out the phase shift proportional to the curvature of the gravitational potential. The scale factor depends only on well controlled quantities, namely the photon wave number, the interferometer time and the atomic recoil, which allows the curvature to be accurately inferred from a measured phase. As a case study, we numerically simulate such a gradiometric interferometer in the context of the Hannover VLBAI facility and prove the robustness of the phase shift in gravitational fields with complex spatial dependence. We define an estimator of the gravitational curvature for non-trivial gravitational fields and calculate the trade-off between signal strength and estimation accuracy with regard to spatial resolution. As a perspective, we discuss the case of a time-dependent gravitational field and corresponding measurement strategies.
The leading experimental determinations of the fine-structure constant α currently rely on atomic photon-recoil measurements from Ramsey-Bordé atom interferometry with large-momentum transfer to provide an absolute mass measurement. We propose an experimental scheme for an intermediate-scale differential atom interferometer to measure the photon recoil of neutral atomic species with a single-photon optical clock transition. We calculate trajectories for our scheme that optimize the recoil phase while nullifying the undesired gravity-gradient phase by considering independently launching two clouds of ultracold atoms with the appropriate initial conditions. For Sr and Yb, we find an atom interferometer of height 3 m to be sufficient for an absolute mass measurement precision of Δ m / m ∼ 1 × 10 − 11 with current technology. Such a precise measurement would halve the current uncertainty in α , an uncertainty that would no longer be limited by an absolute mass measurement. The removal of this limitation would allow the current uncertainty in α to be reduced by a factor of 10 by corresponding improvements in relative mass measurements, thus paving the way for higher-precision tests of the standard model of particle physics. Published by the American Physical Society 2024
This work proposed a theory model for the local photon momentum in a monochromatic optical field. We analysed the transfered momentum when an atom absorbs a photon. Based on the uncertainty principle and Fourier optics theory, we claimed that the atom localization will confine the wavefunction of the absorbed photon that will effect the transfered momentum. We applied our theory to study the systematic effect in the metrology experiment for the fine structure constant based on atom interferometry.
Gravity gradients represent a major obstacle in high-precision measurements by atom interferometry. Controlling their effects to the required stability and accuracy imposes very stringent requirements on the relative positioning of freely falling atomic clouds, as in the case of precise tests of Einstein's equivalence principle. We demonstrate a new method to exactly compensate the effects introduced by gravity gradients in a Raman-pulse atom interferometer. By shifting the frequency of the Raman lasers during the central π pulse, it is possible to cancel the initial position- and velocity-dependent phase shift produced by gravity gradients. We apply this technique to simultaneous interferometers positioned along the vertical direction and demonstrate a new method for measuring local gravity gradients that does not require precise knowledge of the relative position between the atomic clouds. Based on this method, we also propose an improved scheme to determine the Newtonian gravitational constant G towards the 10 ppm relative uncertainty.