Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

New Journal of Physics

Towards the realization of atom trap trace analysis for39Ar

Joachim Welte, Florian Ritterbusch, Isabelle Steinke, M Henrich, Werner Aeschbach, Markus K. Oberthaler

Published Jun 28, 2010• 25 citations
Publisher

Abstract

We present our study of the realization of atom trap trace analysis for 39 Ar, an ultra-sensitive detection method for rare isotopes based on laser cooling. We report on the experimental determination of the hyperfine spectrum of the relevant cooling transition. A high-intensity, optically collimated beam of metastable argon atoms has been set up, and fluorescence detection of single 40 Ar atoms in a magneto-optical trap is realized. The deduced efficiencies of each stage lead to an expected 39 Ar count rate of six atoms per hour in the final setup.

DOI
10.1088/1367-2630/12/6/065031

Related papers

All-optical production and trapping of metastable noble-gas atoms down to the single-atom regime

M. C. Kohler, Heiner Daerr, Peter Sahling +5 more

The determination of isotope ratios of noble-gas atoms has many applications, e.g. , in physics, nuclear-arms control, and Earth sciences. For several applications, the concentration of specific noble-gas isotopes ( e.g. , Kr and Ar) is so low that single-atom detection is highly desirable for a precise determination of the concentration. As an important step in this direction, we demonstrate the operation of a krypton atom trap trace analysis (ATTA) setup based on a magneto-optical trap (MOT) for metastable Kr atoms excited by all-optical means. Compared to other state-of-the-art techniques for preparing metastable noble-gas atoms, all-optical production is capable of overcoming limitations regarding minimal probe volume and avoiding cross-contamination of the samples. In addition, it allows for a compact and reliable setup. We identify optimal parameters of our experimental setup by employing the most abundant isotope 84 Kr, and demonstrate single-atom detection within a 3D MOT.

arXiv:1408.1794•Europhysics Letters (EPL)•Oct 1, 2014•13 citations

Bright metastable noble gas atomic beam and atom trap using laser cooling

Cheng Cun-Feng, Yang Guo-Min, Wei Jiang +5 more

Metastable noble gas atomic beam is widely used in atomic and molecular physics studies.Using radio-frequency discharge and transverse laser cooling, we produced a well-collimated intense meta-stable Krypton beam.Numerical simulation is also used to analyze the trajectories of atoms in an optic field produced by transverse cooling laser beams.The charactersisticl of the atomic beam are determined by measuring the laser induced fluorescence.The atomic beam flux measured at 230 cm downstream is 1.61016 atoms/(s*sr), which is enhanced by two orders of magnitude.The Kr atoms are finally trapped in a magneto-optic trap.A total of 1.31010 meta-stable 84Kr atoms can be simultaneously trapped with a loading rate of 3.01011 atoms/s.The same setup is also successfully used to obtain a bright metastable atomic argon beam and trap.

Acta Physica Sinica•Jan 1, 2011•3 citations

Counting Individual Ca41 Atoms with a Magneto-Optical Trap

Iain D. Moore, K. Bailey, J. P. Greene +6 more

Atom trap trace analysis, a novel method based upon laser trapping and cooling, is used to count individual atoms of $^{41}\mathrm{Ca}$ present in biomedical samples with isotopic abundance levels between ${10}^{\ensuremath{-}8}$ and ${10}^{\ensuremath{-}10}$. The method is calibrated against resonance ionization mass spectrometry, demonstrating good agreement between the two methods. The present system has a counting efficiency of $2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}7}$. Within 1 h of observation time, its $3\mathrm{\text{\ensuremath{-}}}\ensuremath{\sigma}$ detection limit on the isotopic abundance of $^{41}\mathrm{Ca}$ reaches $4.5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}10}$.

arXiv:physics/0310045•Physical Review Letters•Apr 14, 2004•30 citations

Towards precision beta-decay measurements with laser-cooled argon-35

Florence Lenaers, R. D. Glover, Thierry Bastin

Laser cooling and trapping techniques enjoy a solid reputation as powerful and elegant providers of well-localized, backing-free sources. Not only does this hold true within the atomic physics and quantum optics communities, but also beyond. Most notably, these techniques have recently joined the toolbox of low-energy, high-precision tests of the Standard Model. Our work with argon falls within the subset of nuclear beta decay studies, which have historically played a key role in establishing and testing our understanding of weak-interaction physics. In this framework, precision measurements of the beta asymmetry correlation parameter in the beta decay of Ar-35 have been identified as one promising probe for physics beyond the Standard Model. \n \nOur current work focuses on the development of a test magneto-optical trap (MOT) setup for Ar-40 as a preliminary step towards cooling and trapping Ar-35 atoms. In particular, much effort is being put into optimizing the efficiency of our source apparatus, which is crucial to achieving high enough statistics in the final trap. We present the current status of the experimental realization of our setup. \n \nMeasuring the beta asymmetry correlation parameter requires highly spin-polarized samples. Therefore, in parallel to our experimental work, we are numerically investigating methods for generating, controlling and precisely measuring the degree of spin polarization of a sample of Ar-35 atoms. We also aim at being able to quickly switch between a polarized and a non-polarized sample so as to better understand systematic effects. We report on the progress of our theoretical modeling.

•Oct 18, 2016•0 citations

Single-atom detection of calcium isotopes by atom-trap trace analysis

Steven Hoekstra, A. K. Mollema, Reinhard Morgenstern +2 more

We demonstrate a combination of an isotopically purified atom beam and a magneto-optical trap which enables single-atom detection of all stable isotopes of calcium (40, 42, 43, 44, 46, and 48). These isotopes range in abundance from 96.9% $(^{40}\mathrm{Ca})$ to 0.004% $(^{46}\mathrm{Ca})$. The trap is loaded from an atomic beam which is decelerated in a Zeeman slower and subsequently deflected over an angle of 30\ifmmode^\circ\else\textdegree\fi{} by optical molasses. The isotope selectivity of the Zeeman slower and the deflection stage is investigated experimentally and compared with Monte Carlo simulations.

arXiv:physics/0501009•Physical Review A•Feb 16, 2005•18 citations

Towards ultrasensitive isotope trace analysis {sup 41}Ca.

Iain D. Moore, K. Bailey, Zheng‐Tian Lu +3 more

An Atom Trap Trace Analysis (ATTA) system based on the technique of laser manipulation of neutral atoms is being developed to count individual {sup 41}Ca atoms present in natural samples with an isotopic abundance of 10{sup -15}. Trapping of all stable calcium isotopes has been demonstrated and single-atom counting has been realized. For the most abundant isotope, {sup 40}Ca (97% isotopic abundance), a magneto-optical trap (MOT) loading rate of 2 x 10{sup 10} atoms/s has been reached at the overall capture efficiency of 1 x 10{sup -4}. System improvements could increase the efficiency by at least an order of magnitude.

•May 6, 2002•0 citations
We present our study of the realization of atom trap trace analysis for 39 Ar, an ultra-sensitive detection method for rare isotopes based on laser cooling. We report on the experimental determination of the hyperfine spectrum of the relevant cooling transition. A high-intensity, optically collimated beam of metastable argon atoms has been set up, and fluorescence detection of single 40 Ar atoms in a magneto-optical trap is realized. The deduced efficiencies of each stage lead to an expected 39 Ar count rate of six atoms per hour in the final setup.
The determination of isotope ratios of noble-gas atoms has many applications, e.g. , in physics, nuclear-arms control, and Earth sciences. For several applications, the concentration of specific noble-gas isotopes ( e.g. , Kr and Ar) is so low that single-atom detection is highly desirable for a precise determination of the concentration. As an important step in this direction, we demonstrate the operation of a krypton atom trap trace analysis (ATTA) setup based on a magneto-optical trap (MOT) for metastable Kr atoms excited by all-optical means. Compared to other state-of-the-art techniques for preparing metastable noble-gas atoms, all-optical production is capable of overcoming limitations regarding minimal probe volume and avoiding cross-contamination of the samples. In addition, it allows for a compact and reliable setup. We identify optimal parameters of our experimental setup by employing the most abundant isotope 84 Kr, and demonstrate single-atom detection within a 3D MOT.
Metastable noble gas atomic beam is widely used in atomic and molecular physics studies.Using radio-frequency discharge and transverse laser cooling, we produced a well-collimated intense meta-stable Krypton beam.Numerical simulation is also used to analyze the trajectories of atoms in an optic field produced by transverse cooling laser beams.The charactersisticl of the atomic beam are determined by measuring the laser induced fluorescence.The atomic beam flux measured at 230 cm downstream is 1.61016 atoms/(s*sr), which is enhanced by two orders of magnitude.The Kr atoms are finally trapped in a magneto-optic trap.A total of 1.31010 meta-stable 84Kr atoms can be simultaneously trapped with a loading rate of 3.01011 atoms/s.The same setup is also successfully used to obtain a bright metastable atomic argon beam and trap.
Atom trap trace analysis, a novel method based upon laser trapping and cooling, is used to count individual atoms of 41Ca^{41}\mathrm{Ca}41Ca present in biomedical samples with isotopic abundance levels between ${10}^{\ensuremath{-}8}$ and ${10}^{\ensuremath{-}10}$. The method is calibrated against resonance ionization mass spectrometry, demonstrating good agreement between the two methods. The present system has a counting efficiency of $2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}7}$. Within 1 h of observation time, its $3\mathrm{\text{\ensuremath{-}}}\ensuremath{\sigma}$ detection limit on the isotopic abundance of 41Ca^{41}\mathrm{Ca}41Ca reaches $4.5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}10}$.
Laser cooling and trapping techniques enjoy a solid reputation as powerful and elegant providers of well-localized, backing-free sources. Not only does this hold true within the atomic physics and quantum optics communities, but also beyond. Most notably, these techniques have recently joined the toolbox of low-energy, high-precision tests of the Standard Model. Our work with argon falls within the subset of nuclear beta decay studies, which have historically played a key role in establishing and testing our understanding of weak-interaction physics. In this framework, precision measurements of the beta asymmetry correlation parameter in the beta decay of Ar-35 have been identified as one promising probe for physics beyond the Standard Model. \n \nOur current work focuses on the development of a test magneto-optical trap (MOT) setup for Ar-40 as a preliminary step towards cooling and trapping Ar-35 atoms. In particular, much effort is being put into optimizing the efficiency of our source apparatus, which is crucial to achieving high enough statistics in the final trap. We present the current status of the experimental realization of our setup. \n \nMeasuring the beta asymmetry correlation parameter requires highly spin-polarized samples. Therefore, in parallel to our experimental work, we are numerically investigating methods for generating, controlling and precisely measuring the degree of spin polarization of a sample of Ar-35 atoms. We also aim at being able to quickly switch between a polarized and a non-polarized sample so as to better understand systematic effects. We report on the progress of our theoretical modeling.
We demonstrate a combination of an isotopically purified atom beam and a magneto-optical trap which enables single-atom detection of all stable isotopes of calcium (40, 42, 43, 44, 46, and 48). These isotopes range in abundance from 96.9% (40Ca)(^{40}\mathrm{Ca})(40Ca) to 0.004% (46Ca)(^{46}\mathrm{Ca})(46Ca). The trap is loaded from an atomic beam which is decelerated in a Zeeman slower and subsequently deflected over an angle of 30\ifmmode^\circ\else\textdegree\fi{} by optical molasses. The isotope selectivity of the Zeeman slower and the deflection stage is investigated experimentally and compared with Monte Carlo simulations.
An Atom Trap Trace Analysis (ATTA) system based on the technique of laser manipulation of neutral atoms is being developed to count individual {sup 41}Ca atoms present in natural samples with an isotopic abundance of 10{sup -15}. Trapping of all stable calcium isotopes has been demonstrated and single-atom counting has been realized. For the most abundant isotope, {sup 40}Ca (97% isotopic abundance), a magneto-optical trap (MOT) loading rate of 2 x 10{sup 10} atoms/s has been reached at the overall capture efficiency of 1 x 10{sup -4}. System improvements could increase the efficiency by at least an order of magnitude.