Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Low Temperature Physics

An Analysis of Stability in Frequency Multiplexed TES Arrays

Renzo Vaccarone

Published Jan 23, 2008• 1 citation
Publisher
DOI
10.1007/s10909-008-9767-9

Related papers

Recent Advances in Frequency-Multiplexed TES Readout: Vastly Reduced Parasitics and an Increase in Multiplexing Factor with Sub-Kelvin SQUIDs

T. de Haan, A. Suzuki, S. T. P. Boyd +9 more

arXiv:1908.07642•Journal of Low Temperature Physics•Feb 28, 2020•11 citations

Feasibility of a Frequency-Multiplexed TES Read-Out Using Superconducting Tunnel Junctions

Gert J. de Lange

Journal of Low Temperature Physics•Jan 9, 2014•8 citations

Performance Measurement of the 8-Input SQUIDs for TES Frequency Domain Multiplexing

Shunsuke Kimura, Kensuke Masui, Yoh Takei +5 more

Journal of Low Temperature Physics•Jan 23, 2008•4 citations

Multiplexing technology based on SQUID for readout of superconducting transition-edge sensor arrays

Xinyu Wu, Qing Yu, Yongcheng He +2 more

Multiplexing technologies based on superconducting quantum interference devices (SQUIDs) are crucial to cryogenic readout of superconducting transition-edge sensor (TES) arrays. Demands for large-scale TES arrays promote the development of multiplexing technologies towards large multiplexing factors and low readout noise. The development of multiplexing technologies also facilitates new applications of TES arrays in a wide range of frequencies. Here we summarize different types of SQUID-based multiplexing technologies including time-division multiplexing, code-division multiplexing, frequency-division multiplexing and microwave SQUID multiplexing. The advances and parameter constraints of each multiplexing technology are also discussed.

Chinese Physics B•Apr 22, 2022•6 citations

Readout demonstration of 512 TES bolometers using a single microwave SQUID multiplexer (Conference Presentation)

Bradley Dober, Zeeshan Ahmed, Jason E. Austermann +30 more

To enable the next-generation of bolometric cameras, we are developing the microwave SQUID multiplexer (μMUX). Upcoming receivers such as Simons Observatory, CCAT-prime, BICEP array, Ali-CPT, and CMB-S4 plan to instrument focal planes with 50,000-500,000 sensors. Sensor count is achieved by tiling many 150 mm-diameter densely packed detector arrays into these focal planes. The fabrication and quality of large-format bolometer arrays has been demonstrated and is now mature. In contrast, the readout technology required for next-generation receivers needs development. The sensitivity, low cross-talk, high multiplexing density, and small component size make the μMUX well-suited for this goal. In this approach, the TES signal modulates the inductance of an rf-SQUID that loads a high-Q microwave resonator. The coupled signal therefore modulates the microwave resonance frequency, which may be read out using homodyne techniques. By coupling each resonator to the same microwave feedline, many detectors can be read out on a single coaxial cable pair. The multiplexing density is in practice limited by signal bandwidth, allowable cross-talk, and the digitization bandwidth of room-temperature readout electronics. We present the design and performance of a scalable 64-channel multiplexer chip optimized for bolometric applications. We utilize a new quarter wave resonator design that increases the physical linear density by a factor of two, therefore achieving a smaller footprint for simplified detector packaging. Measurements of this design show 100 kHz resonator bandwidth, uniform 1.8 MHz frequency spacing, and an input referred current noise of 35 pA/√Hz that is well below the level of an optimized, background-limited TES bolometer. Using 8 daisy-chained and frequency scaled chips, we create a 512-channel multiplexer and use it to readout a 512 TES-bolometer array. We present the results of this large-scale μMUX demonstration including system yield, signal cross-talk, and an analysis of noise in various TES bias configurations. The result demonstrates the multiplexing density required to read out 2,000 sensors between 4-8 GHz.

Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy XI•Jul 10, 2018•1 citation

Frequency shifts in resonant systems

Richard M. Friedberg, Sven R. Hartmann, Jamal T. Manassah

Physics Letters A•May 1, 1971•15 citations
Multiplexing technologies based on superconducting quantum interference devices (SQUIDs) are crucial to cryogenic readout of superconducting transition-edge sensor (TES) arrays. Demands for large-scale TES arrays promote the development of multiplexing technologies towards large multiplexing factors and low readout noise. The development of multiplexing technologies also facilitates new applications of TES arrays in a wide range of frequencies. Here we summarize different types of SQUID-based multiplexing technologies including time-division multiplexing, code-division multiplexing, frequency-division multiplexing and microwave SQUID multiplexing. The advances and parameter constraints of each multiplexing technology are also discussed.
To enable the next-generation of bolometric cameras, we are developing the microwave SQUID multiplexer (μMUX). Upcoming receivers such as Simons Observatory, CCAT-prime, BICEP array, Ali-CPT, and CMB-S4 plan to instrument focal planes with 50,000-500,000 sensors. Sensor count is achieved by tiling many 150 mm-diameter densely packed detector arrays into these focal planes. The fabrication and quality of large-format bolometer arrays has been demonstrated and is now mature. In contrast, the readout technology required for next-generation receivers needs development. The sensitivity, low cross-talk, high multiplexing density, and small component size make the μMUX well-suited for this goal. In this approach, the TES signal modulates the inductance of an rf-SQUID that loads a high-Q microwave resonator. The coupled signal therefore modulates the microwave resonance frequency, which may be read out using homodyne techniques. By coupling each resonator to the same microwave feedline, many detectors can be read out on a single coaxial cable pair. The multiplexing density is in practice limited by signal bandwidth, allowable cross-talk, and the digitization bandwidth of room-temperature readout electronics. We present the design and performance of a scalable 64-channel multiplexer chip optimized for bolometric applications. We utilize a new quarter wave resonator design that increases the physical linear density by a factor of two, therefore achieving a smaller footprint for simplified detector packaging. Measurements of this design show 100 kHz resonator bandwidth, uniform 1.8 MHz frequency spacing, and an input referred current noise of 35 pA/√Hz that is well below the level of an optimized, background-limited TES bolometer. Using 8 daisy-chained and frequency scaled chips, we create a 512-channel multiplexer and use it to readout a 512 TES-bolometer array. We present the results of this large-scale μMUX demonstration including system yield, signal cross-talk, and an analysis of noise in various TES bias configurations. The result demonstrates the multiplexing density required to read out 2,000 sensors between 4-8 GHz.