Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Europhysics Letters (EPL)

Can spontaneous emission be influenced by the presence of a distant detector?

B. Crosignani, Paolo Di Porto

Published Jul 20, 1996• 5 citations
Publisher

Abstract

We show that the spontaneous-emission process could be altered by continuously monitoring the emitting system by means of a spherical counter of quantum efficiency η < 1, placed at a finite distance L . This surprising result is related neither to Zeno's effect nor to any cavity effect, but is of intrinsically quantum-mechanical non-local nature.

DOI
10.1209/epl/i1996-00549-4

Related papers

The presence of a distant detector does not seem to influence spontaneous emission

Luiz Carlos Ryff

It is shown that a recent claim, according to which the spontaneous-emission process could be altered by continuously monitoring the emitting system by means of a spherical counter of quantum efficiency η < 1 placed at a finite distance L , is unfounded. The error arises from an incorrect reasoning.

Europhysics Letters (EPL)•Jul 15, 1997•4 citations

Spontaneous emission and non-locality in quantum mechanics

B. Crosignani, Paolo Di Porto

We describe a thought experiment in which the decay rate of an ensemble of excited atoms turns out to depend on both the efficiency and geometry of the counters used to detect the emitted photons. This quantum mechanical effect, of intrinsically non-local nature, implies an enhancing of the atomic decay rate and is present under experimental conditions completely different from those giving rise to the freezing of atomic decay corresponding to quantum Zeno effect.

Quantum Optics Journal of the European Optical Society Part B•Jun 1, 1994•3 citations

Possibility of Quantum Zeno Effect for Distant Indirect Measurement

Masahiro Hotta, Masahiro Morikawa

We critically study the possibility of quantum Zeno effect for indirect measurements. If the detector is prepared to detect the emitted signal from the core system, and the detector does not reflect the signal back to the core system, then we can prove the decay probability of the system is not changed by the continuous measurement of the signal and the quantum Zeno effect never takes place. This argument also applies to the quantum Zeno effect for accelerated two-level systems, unstable particle decay, etc.

•Oct 14, 2003•0 citations

Impossibility of distant indirect measurement of the quantum Zeno effect

Masahiro Hotta, Masahiro Morikawa

We critically study the possibility of the quantum Zeno effect for indirect measurements. If the detector is prepared to detect the emitted signal from the core system, and does not reflect this signal back to the core system, then we can prove that the decay probability of the system is not changed by the continuous measurement of the signal and the quantum Zeno effect would never take place. This argument also applies to the quantum Zeno effect for accelerated two-level systems and unstable particle decays.

arXiv:quant-ph/0310090•Physical Review A•May 20, 2004•15 citations

Reply to the paper “The presence of a distant detector does not seem to influence spontaneous emission” by L. C. Ryff

B. Crosignani, Paolo Di Porto

We confute the criticism contained in a paper appearing in this issue of Europhys. Lett. , in which the author claims that the main result of a series of our papers concerning the influence of a distant detector on spontaneous emission is unfounded.

Europhysics Letters (EPL)•Jul 15, 1997•2 citations

Suppression of Zeno effect for distant detectors

F.S. Delgado, Juan Gonzalo Muga, Gastón García‐Calderón

We describe the influence of continuous measurement in a decaying system and the role of the distance from the detector to the initial location of the system. The detector is modeled first by a step absorbing potential. For a close and strong detector, the decay rate of the system is reduced; weaker detectors do not modify the exponential decay rate but suppress the long-time deviations above a coupling threshold. Nevertheless, these perturbing effects of measurement disappear by increasing the distance between the initial state and the detector, as well as by improving the efficiency of the detector.

arXiv:quant-ph/0604005•Physical Review A•Dec 5, 2006•13 citations
We show that the spontaneous-emission process could be altered by continuously monitoring the emitting system by means of a spherical counter of quantum efficiency η < 1, placed at a finite distance L . This surprising result is related neither to Zeno's effect nor to any cavity effect, but is of intrinsically quantum-mechanical non-local nature.
We critically study the possibility of quantum Zeno effect for indirect measurements. If the detector is prepared to detect the emitted signal from the core system, and the detector does not reflect the signal back to the core system, then we can prove the decay probability of the system is not changed by the continuous measurement of the signal and the quantum Zeno effect never takes place. This argument also applies to the quantum Zeno effect for accelerated two-level systems, unstable particle decay, etc.
We critically study the possibility of the quantum Zeno effect for indirect measurements. If the detector is prepared to detect the emitted signal from the core system, and does not reflect this signal back to the core system, then we can prove that the decay probability of the system is not changed by the continuous measurement of the signal and the quantum Zeno effect would never take place. This argument also applies to the quantum Zeno effect for accelerated two-level systems and unstable particle decays.
We describe the influence of continuous measurement in a decaying system and the role of the distance from the detector to the initial location of the system. The detector is modeled first by a step absorbing potential. For a close and strong detector, the decay rate of the system is reduced; weaker detectors do not modify the exponential decay rate but suppress the long-time deviations above a coupling threshold. Nevertheless, these perturbing effects of measurement disappear by increasing the distance between the initial state and the detector, as well as by improving the efficiency of the detector.