Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Loss-error compensation in quantum-state measurements and the solution of the time-reversed damping equation

Ulrike Herzog

Published Mar 1, 1996• 28 citations
Publisher

Abstract

Making use of a generating-function approach, an effective mathematical procedure is derived for the compensation of detection-loss induced errors in quantum-state measurements at any value of the overall detection efficiency \ensuremath{\eta}. The connection with the solution of the time-reversed damping equation is discussed. \textcopyright{} 1996 The American Physical Society.

DOI
10.1103/physreva.53.1245

Related papers

Compensation of losses in photodetection and in quantum-state measurements

T. Kiss, Ulrike Herzog, Ulf Leonhardt

We show how losses in photodetection and in quantum-state measurements can be numerically compensated after the measurements have been performed. When the overall efficiency exceeds 1/2, our recipe works for all quantum states. For smaller efficiencies, however, the convergence of the compensation procedure depends on the quantum state under investigation.

Physical Review A•Sep 1, 1995•104 citations

Reconstruction of the quantum state via position distribution and its time derivative

Th. Richter

The determination of the harmonic oscillator wave function from position distribution and its time derivative is investigated. Quite simple definitive equations result for the expansion coefficients of the wave function in the Fock basis and yield a unique solution. The effect of a finite spatial resolution of the measurements is taken into account. \textcopyright{} 1996 The American Physical Society.

Physical Review A•Sep 1, 1996•3 citations

Loss-error compensation in quantum-state measurements

Giacomo Mauro D’Ariano, Chiara Macchiavello

In the two papers [T. Kiss, U. Herzog, and U. Leonhardt, Phys. Rev. A 52, 2433 (1995); U. Herzog, Phys. Rev. A 53, 1245 (1996)] with titles similar to the one given above, the authors assert that in some cases it is possible to compensate a quantum efficiency $\ensuremath{\eta}<~1/2$ in quantum-state measurements, violating the lower bound $1/2$ proved in a preceding paper [G. M. D'Ariano, U. Leonhardt, and H. Paul, Phys. Rev. A 52, R1801 (1995)]. Here we reestablish the bound for homodyning any quantum state, and show how the proposed loss-compensation method would fail in a real measurement outside the $\ensuremath{\eta}>1/2$ regime.

arXiv:quant-ph/9701009•Physical Review A•Apr 1, 1998•32 citations

Quantum advantage of time-reversed ancilla-based metrology of absorption parameters

Jiaxuan Wang, R. L. de Matos Filho, G. S. Agarwal +1 more

Quantum estimation of parameters defining open-system dynamics may be enhanced by using ancillas that are entangled with the probe but are not submitted to the dynamics. Here we consider the important problem of estimation of transmission of light by a sample, with losses due to absorption and scattering. We show, through the determination of the quantum Fisher information, that the ancilla strategy leads to the best possible precision in single-mode estimation—the one obtained for a Fock-state input—through joint photon counting of probe and ancilla, which are modes of a bimodal squeezed state produced by an optical parametric amplifier. This proposal overcomes the challenge of producing and detecting high-photon-number Fock states, and it is quite robust in the presence of additional noise: We show that it is immune to phase noise and the precision does not change if the incoming state gets disentangled. Furthermore, the quantum gain is still present under moderate photon losses of the input beams. We also discuss an alternative to joint photon counting, which is readily implementable with present technology and approaches the quantum Fisher information result for weak absorption, even with moderate photon losses of the input beams before the sample is probed: a time-reversal procedure, placing the sample between two optical parametric amplifiers, with the second undoing the squeezing produced by the first one. The precision of estimation of the loss parameter is obtained from the average outgoing total photon number and its variance. In both procedures, the state of the probe and the detection procedure are independent of the value of the parameter. Published by the American Physical Society 2024

arXiv:2310.06142•Physical Review Research•Jan 10, 2024•14 citations

Reconstruction of the Quantum State via Position Distribution and its Time Derivative

T. Richter

The determination of the harmonic oscillator wave function from position distribution and its time derivative is investigated. Quite simple definitive equations result for the expansion coefficients of the wave function in the Fock basis and yield a unique solution. The effect of a finite spatial resolution of the measurements is taken into account. {copyright} {ital 1996 The American Physical Society.}

European Quantum Electronics Conference (EQEC)•Jan 1, 1996•1 citation

Reply to “Loss-error compensation in quantum-state measurements”

T. Kiss, Ulrike Herzog, Ulf Leonhardt

The authors of the preceding Comment [G. M. D'Ariano and C. Macchiavello, preceding paper, Phys. Rev. A 57, 3131 (1998)] tried to reestablish a $0.5$ efficiency bound for loss compensation in optical homodyne tomography. In our reply we demonstrate that neither does such a rigorous bound exist nor is the bound required for ruling out the state reconstruction of an individual system [G. M. D'Ariano and H. P. Yuen, Phys. Rev. Lett. 76, 2832 (1996)].

arXiv:quant-ph/9801028•Physical Review A•Apr 1, 1998•16 citations
Making use of a generating-function approach, an effective mathematical procedure is derived for the compensation of detection-loss induced errors in quantum-state measurements at any value of the overall detection efficiency \ensuremath{\eta}. The connection with the solution of the time-reversed damping equation is discussed. \textcopyright{} 1996 The American Physical Society.
In the two papers [T. Kiss, U. Herzog, and U. Leonhardt, Phys. Rev. A 52, 2433 (1995); U. Herzog, Phys. Rev. A 53, 1245 (1996)] with titles similar to the one given above, the authors assert that in some cases it is possible to compensate a quantum efficiency $\ensuremath{\eta}<~1/2$ in quantum-state measurements, violating the lower bound 1/21/21/2 proved in a preceding paper [G. M. D'Ariano, U. Leonhardt, and H. Paul, Phys. Rev. A 52, R1801 (1995)]. Here we reestablish the bound for homodyning any quantum state, and show how the proposed loss-compensation method would fail in a real measurement outside the $\ensuremath{\eta}>1/2$ regime.
Quantum estimation of parameters defining open-system dynamics may be enhanced by using ancillas that are entangled with the probe but are not submitted to the dynamics. Here we consider the important problem of estimation of transmission of light by a sample, with losses due to absorption and scattering. We show, through the determination of the quantum Fisher information, that the ancilla strategy leads to the best possible precision in single-mode estimation—the one obtained for a Fock-state input—through joint photon counting of probe and ancilla, which are modes of a bimodal squeezed state produced by an optical parametric amplifier. This proposal overcomes the challenge of producing and detecting high-photon-number Fock states, and it is quite robust in the presence of additional noise: We show that it is immune to phase noise and the precision does not change if the incoming state gets disentangled. Furthermore, the quantum gain is still present under moderate photon losses of the input beams. We also discuss an alternative to joint photon counting, which is readily implementable with present technology and approaches the quantum Fisher information result for weak absorption, even with moderate photon losses of the input beams before the sample is probed: a time-reversal procedure, placing the sample between two optical parametric amplifiers, with the second undoing the squeezing produced by the first one. The precision of estimation of the loss parameter is obtained from the average outgoing total photon number and its variance. In both procedures, the state of the probe and the detection procedure are independent of the value of the parameter. Published by the American Physical Society 2024
The authors of the preceding Comment [G. M. D'Ariano and C. Macchiavello, preceding paper, Phys. Rev. A 57, 3131 (1998)] tried to reestablish a 0.50.50.5 efficiency bound for loss compensation in optical homodyne tomography. In our reply we demonstrate that neither does such a rigorous bound exist nor is the bound required for ruling out the state reconstruction of an individual system [G. M. D'Ariano and H. P. Yuen, Phys. Rev. Lett. 76, 2832 (1996)].