Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics B

An analytical model for evaporative cooling of atoms

Kendall B. Davis, M.‐O. Mewes, Wolfgang Ketterle

Published Jan 1, 1995• 113 citations
Publisher
DOI
10.1007/bf01135857

Related papers

Dynamic equation for evaporative cooling of trapped atoms in microgravity

Xiaolong Yuan, Jiachen Yu, H. Li +4 more

In this paper, to investigate how atoms evaporate and cool in microgravity environments of the space station, we have developed the dynamic equation for evaporative cooling of trapped atoms and obtained the analytical expression of atomic temperature with respect to trapping laser parameters and gravitational acceleration. In our model, the evaporation of atoms is equivalent to applying a damping force to the trapped atoms, and the evaporative cooling process of trapped atoms is comprehended as the damped oscillation of trapped atoms in the optical dipole traps. By introducing the gravity in our model, we obtained the analytical model of temperature variation with gravity after cooling, and the theoretical results agree well with the evaporation experiment of rubidium-87 atoms on the ground. Our theoretical results show that, compared with the atomic evaporative cooling experiment on the ground, the microgravity environment of the space station can achieve cooler atomic gases when the losses of atoms, such as the one-body loss caused by background-gas collisions and the three-body recombination loss caused by interatomic inelastic collisions, can be ignored.

Physical Review A•Apr 16, 2024•2 citations

Evaporative Cooling of Trapped Atoms

Wolfgang Ketterle, N. J. van Druten

Advances in atomic, molecular, and optical physics•Jan 1, 1996•630 citations

Evaporative cooling of an atomic beam

Emmanuel Mandonnet, Anna Minguzzi, Ralph Dum +3 more

arXiv:cond-mat/9909378•The European Physical Journal D•Mar 1, 2000•71 citations

Evaporative cooling at low trap depth

Robert deCarvalho, John M. Doyle

A quantitative, analytic model of evaporative cooling covering both the small- $(<4)$ and large- $(>4)$ $\ensuremath{\eta}$ regimes is presented. $\ensuremath{\eta}$ is the dimensionless parameter defined as the trap depth divided by the temperature of the trapped sample. Although some of the same general properties present at large $\ensuremath{\eta}$ are also present at small $\ensuremath{\eta}$, there are significant quantitative differences. These differences must be taken into account in order to accurately extract from the trapping data quantitative measurements of, for example, collisional atomic cross sections.

Physical Review A•Nov 18, 2004•17 citations

An atom laser based on evaporative cooling

Howard M. Wiseman, Ana María Guerra Martins, Daniel F. Walls

An atom laser is a device which would ideally produce a coherent excitation of a single mode of the Bose-atom field. That is to say, an atom laser field would have a well defined number of atoms, and a slow rate of phase diffusion. Here we consider an atom laser model recently proposed by Holland et al, based on evaporative cooling of atoms. We extend their model, and give approximate analytical results for the time-dependent intensity and phase statistics of the atom laser in different regimes. Although the intensity fluctuations may be relatively small, the laser linewidth is always in excess of the bare linewidth of the laser mode. Nevertheless, in one regime (weak collisions), the laser linewidth may be less than the output flux of atoms, which is a minimum requirement for considering the output to be coherent.

Quantum and Semiclassical Optics Journal of the European Optical Society Part B•Jun 1, 1996•59 citations

Evaporative Cooling of Sodium Atoms

Kendall B. Davis, M.‐O. Mewes, Michael A. Joffe +2 more

Physical Review Letters•Oct 9, 1995•16 citations
In this paper, to investigate how atoms evaporate and cool in microgravity environments of the space station, we have developed the dynamic equation for evaporative cooling of trapped atoms and obtained the analytical expression of atomic temperature with respect to trapping laser parameters and gravitational acceleration. In our model, the evaporation of atoms is equivalent to applying a damping force to the trapped atoms, and the evaporative cooling process of trapped atoms is comprehended as the damped oscillation of trapped atoms in the optical dipole traps. By introducing the gravity in our model, we obtained the analytical model of temperature variation with gravity after cooling, and the theoretical results agree well with the evaporation experiment of rubidium-87 atoms on the ground. Our theoretical results show that, compared with the atomic evaporative cooling experiment on the ground, the microgravity environment of the space station can achieve cooler atomic gases when the losses of atoms, such as the one-body loss caused by background-gas collisions and the three-body recombination loss caused by interatomic inelastic collisions, can be ignored.
A quantitative, analytic model of evaporative cooling covering both the small- (<4)(<4)(<4) and large- (>4)(>4)(>4) $\ensuremath{\eta}$ regimes is presented. $\ensuremath{\eta}$ is the dimensionless parameter defined as the trap depth divided by the temperature of the trapped sample. Although some of the same general properties present at large $\ensuremath{\eta}$ are also present at small $\ensuremath{\eta}$, there are significant quantitative differences. These differences must be taken into account in order to accurately extract from the trapping data quantitative measurements of, for example, collisional atomic cross sections.
An atom laser is a device which would ideally produce a coherent excitation of a single mode of the Bose-atom field. That is to say, an atom laser field would have a well defined number of atoms, and a slow rate of phase diffusion. Here we consider an atom laser model recently proposed by Holland et al, based on evaporative cooling of atoms. We extend their model, and give approximate analytical results for the time-dependent intensity and phase statistics of the atom laser in different regimes. Although the intensity fluctuations may be relatively small, the laser linewidth is always in excess of the bare linewidth of the laser mode. Nevertheless, in one regime (weak collisions), the laser linewidth may be less than the output flux of atoms, which is a minimum requirement for considering the output to be coherent.