Physical Review A

Precise measurement of the Stark shift of the rubidium and potassiumD1 lines

Kenneth E. Miller, D. Krause, L. R. Hunter

Published Jun 1, 1994• 29 citations
Publisher

Abstract

The dc Stark shift of the D1 lines of rubidium and potassium are observed using a pair of cavity-stabilized diode lasers locked to resonance signals. The heterodyne signal from the two lasers and the optical measurements of the electrode spacing yield high-precision results. The observed scalar shifts are found to be 61.153(8) kHz (kV/cm${)}^{\mathrm{\ensuremath{-}}2}$ for rubidium and 39.400(5) kHz (kV/cm${)}^{\mathrm{\ensuremath{-}}2}$ for potassium. These results represent more than three orders of magnitude improvement in our knowledge of these Stark shifts.

DOI
10.1103/physreva.49.5128

Related papers

Precise measurement of the Stark shift of the lithiumD1 line

L. R. Hunter, D. E. Krause, Dana J. Berkeland +1 more

The dc Stark shift of the lithium D1 line has been observed using two visible diode lasers and an atomic beam. A heterodyne signal obtained from the two lasers permits a well-calibrated, high-precision measurement to be made. The scalar shift is found to be 4.6216(21) kHz/(kV/cm${)}^{2}$. We believe this result to be the most precise Stark shift measurement reported thus far.

Physical Review A•Nov 1, 1991•36 citations

Stark Effect of the RubidiumD2 Line Studied by High-Resolution Laser Spectroscopy

Masayuki Kawamura, Wei-Guo Jin, Nobuyuki Takahashi +1 more

The Stark effect of the 5 s 2 S 1/2 –5 p 2 P 3/2 transition ( D 2 line) of Rb has been studied by high-resolution atomic-beam laser spectroscopy. The splittings of magnetic sublevels of 5 p 2 P 3/2 have been resolved, and the Stark shifts and splittings of the D 2 line have been measured at various electric fields. The scalar polarizability of the D 2 line and the tensor polarizability of the 5 p 2 P 3/2 level have been determined to be α s (5 p 2 P 3/2 ) - α s (5 s 2 S 1/2 ) = 136.95(89) kHz/(kV/cm) 2 and α t (5 p 2 P 3/2 ) = -40.91(38) kHz/(kV/cm) 2 , respectively, by considering the mixing between hyperfine structure levels of 5 p 2 P 3/2 . The precision of α t (5 p 2 P 3/2 ) has been improved by a factor of 2 compared with the previously reported values.

Journal of the Physical Society of Japan•Dec 10, 2009•7 citations

Coherent optical transient measurements of absolute and differential Stark shifts in atomic sodium

Peter Hannaford, W. R. MacGillivray, M. C. Standage

A coherent optical transient technique has been used for the first time to study the Stark effect in atoms. This technique involves the recording of transients in the intensity of single-mode laser radiation transmitted by an atomic vapour following the sudden application of an electric-field pulse. It allows both absolute and differential Stark shifts to be measured to a precision which is limited only by the power-broadened natural linewidth of the transition. The feasibility of this technique is demonstrated by measuring the scalar ( alpha0) and tensor ( alpha2) polarisabilities associated with the sodium 32P1/2and 32P3/2levels of sodium. The resolution is such that the effect of the hyperfine structure on the Stark shifts has to be included in the analysis. Our values for the polarisabilities are alpha0=0+or-3.3 kHz (kV cm-1)-2and alpha2=28.1+or-3.9 KHz (kV cm-1)-2. These results are compared with experimental and theoretical values obtained by other authors.

Journal of Physics B Atomic and Molecular Physics•Dec 28, 1979•9 citations

Observation of rubidium 5S_1/2→7S_1/2 two-photon transitions with a diode laser

Ming-Sheng Ko, Yi-Wei Liu

The 5S1/2 --> 7S1/2 two-photon transition of atomic rubidium, which is 100 times weaker than the 5S-5D transition, is observed with an extended-cavity diode laser and a vapor cell. Signals with a signal-to-noise ratio of 280 are obtained with a laser power of 10 mW, and the observed linewidth is 3 MHz. The laser wavelength is 760 nm and is locked on the transitions to a stability of 2 x 10(-11). For the first time to our knowledge, the isotope shift of this transition is measured to be 130(4) MHz in atomic frequency.

Optics Letters•Aug 1, 2004•20 citations

Stark-shift measurement of the (6s )2 1 S0 →(6s6p )1 P1 barium transition

Junlei Li, William Arie van Wijngaarden

The Stark shift of the (6s${)}^{2}$ $^{1}$${\mathit{S}}_{0}$\ensuremath{\rightarrow}(6s6p${)}^{1}$${\mathit{P}}_{1}$ transition in barium was measured using a laser to excite an atomic beam as it traversed a uniform electric field and a field-free region. The laser frequency was scanned across the transition while fluorescence produced by the radiative decay of the excited state was detected. The frequency scan was calibrated using an acousto-optic modulator which frequency shifted the laser by a specified amount. The Stark-shift rate was found to be -28.532\ifmmode\pm\else\textpm\fi{}0.060 kHz/(kV/cm${)}^{2}$. The hyperfine splitting of the $^{135,137}\mathrm{Ba}$ F=1/2 level relative to $^{138}\mathrm{Ba}$ of the (6s6p${)}^{1}$${\mathit{P}}_{1}$ state was determined to be -549.47\ifmmode\pm\else\textpm\fi{}0.12 MHz, where the minus sign indicates that the $^{138}\mathrm{Ba}$ transition is at a lower frequency.

Physical Review A•May 1, 1995•12 citations

Solitary resonance observed in the saturated absorption spectrum of the 87 Rb D 2 line

Normand Cyr, M. Têtu

In recent years, much work has been done in experimental studies to frequency lock laser diodes to atomic or molecular resonances.1 By such techniques it is possible to improve greatly the laser frequency stability and to define precisely its nominal value. For laser sources operating in the 0.8-μm range, rubidium is the preferred specie and each isotope offers two resonance lines, one at 780 nm (D2 line) and one at 795 nm (D1 line). Both linear and saturated absorption have been used, and laser frequency charcteristics are published.2,3

•Apr 24, 1989•1 citation
The dc Stark shift of the D1 lines of rubidium and potassium are observed using a pair of cavity-stabilized diode lasers locked to resonance signals. The heterodyne signal from the two lasers and the optical measurements of the electrode spacing yield high-precision results. The observed scalar shifts are found to be 61.153(8) kHz (kV/cm)\ensuremath−2{)}^{\mathrm{\ensuremath{-}}2})\ensuremath−2 for rubidium and 39.400(5) kHz (kV/cm)\ensuremath−2{)}^{\mathrm{\ensuremath{-}}2})\ensuremath−2 for potassium. These results represent more than three orders of magnitude improvement in our knowledge of these Stark shifts.
The dc Stark shift of the lithium D1 line has been observed using two visible diode lasers and an atomic beam. A heterodyne signal obtained from the two lasers permits a well-calibrated, high-precision measurement to be made. The scalar shift is found to be 4.6216(21) kHz/(kV/cm)2{)}^{2})2. We believe this result to be the most precise Stark shift measurement reported thus far.
The Stark effect of the 5 s 2 S 1/2 –5 p 2 P 3/2 transition ( D 2 line) of Rb has been studied by high-resolution atomic-beam laser spectroscopy. The splittings of magnetic sublevels of 5 p 2 P 3/2 have been resolved, and the Stark shifts and splittings of the D 2 line have been measured at various electric fields. The scalar polarizability of the D 2 line and the tensor polarizability of the 5 p 2 P 3/2 level have been determined to be α s (5 p 2 P 3/2 ) - α s (5 s 2 S 1/2 ) = 136.95(89) kHz/(kV/cm) 2 and α t (5 p 2 P 3/2 ) = -40.91(38) kHz/(kV/cm) 2 , respectively, by considering the mixing between hyperfine structure levels of 5 p 2 P 3/2 . The precision of α t (5 p 2 P 3/2 ) has been improved by a factor of 2 compared with the previously reported values.
A coherent optical transient technique has been used for the first time to study the Stark effect in atoms. This technique involves the recording of transients in the intensity of single-mode laser radiation transmitted by an atomic vapour following the sudden application of an electric-field pulse. It allows both absolute and differential Stark shifts to be measured to a precision which is limited only by the power-broadened natural linewidth of the transition. The feasibility of this technique is demonstrated by measuring the scalar ( alpha0) and tensor ( alpha2) polarisabilities associated with the sodium 32P1/2and 32P3/2levels of sodium. The resolution is such that the effect of the hyperfine structure on the Stark shifts has to be included in the analysis. Our values for the polarisabilities are alpha0=0+or-3.3 kHz (kV cm-1)-2and alpha2=28.1+or-3.9 KHz (kV cm-1)-2. These results are compared with experimental and theoretical values obtained by other authors.
The 5S1/2 --> 7S1/2 two-photon transition of atomic rubidium, which is 100 times weaker than the 5S-5D transition, is observed with an extended-cavity diode laser and a vapor cell. Signals with a signal-to-noise ratio of 280 are obtained with a laser power of 10 mW, and the observed linewidth is 3 MHz. The laser wavelength is 760 nm and is locked on the transitions to a stability of 2 x 10(-11). For the first time to our knowledge, the isotope shift of this transition is measured to be 130(4) MHz in atomic frequency.
The Stark shift of the (6s)2{)}^{2})2 1^{1}1S0{\mathit{S}}_{0}S0​\ensuremath{\rightarrow}(6s6p)1{)}^{1})1P1{\mathit{P}}_{1}P1​ transition in barium was measured using a laser to excite an atomic beam as it traversed a uniform electric field and a field-free region. The laser frequency was scanned across the transition while fluorescence produced by the radiative decay of the excited state was detected. The frequency scan was calibrated using an acousto-optic modulator which frequency shifted the laser by a specified amount. The Stark-shift rate was found to be -28.532\ifmmode\pm\else\textpm\fi{}0.060 kHz/(kV/cm)2{)}^{2})2. The hyperfine splitting of the 135,137Ba^{135,137}\mathrm{Ba}135,137Ba F=1/2 level relative to 138Ba^{138}\mathrm{Ba}138Ba of the (6s6p)1{)}^{1})1P1{\mathit{P}}_{1}P1​ state was determined to be -549.47\ifmmode\pm\else\textpm\fi{}0.12 MHz, where the minus sign indicates that the 138Ba^{138}\mathrm{Ba}138Ba transition is at a lower frequency.
In recent years, much work has been done in experimental studies to frequency lock laser diodes to atomic or molecular resonances.1 By such techniques it is possible to improve greatly the laser frequency stability and to define precisely its nominal value. For laser sources operating in the 0.8-μm range, rubidium is the preferred specie and each isotope offers two resonance lines, one at 780 nm (D2 line) and one at 795 nm (D1 line). Both linear and saturated absorption have been used, and laser frequency charcteristics are published.2,3