Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE

Reduction of quantum noise in image estimation by use of twin-photon beams

Majeed M. Hayat, Bahaa E. A. Saleh, John A. Gubner

Published Oct 25, 1996• 0 citations
Publisher

Abstract

An estimate of the transmittance of an object is examined in a twin-photon beam setup. The estimate is based on observing both the photons of one beam and the photons of the twin beam after passage through the object. The performance of the estimate (bias, variance, and mean-square error) is compared to the conventional single-beam measurement. The improvement depends on the photon flux, the counting time, the quantum efficiencies of the detectors, and the value of the measured transmittance itself. In general, a performance advantage is achieved for sufficiently high photon flux or long counting time.

DOI
10.1117/12.255087

Related papers

Reduction of quantum noise in transmittance estimation using photon-correlated beams

Majeed M. Hayat, Adel Joobeur, Bahaa E. A. Saleh

The accuracy of optical measurements at low light levels is limited by the quantum noise of the source and by the random nature of the interaction with the measured object. The source noise may be reduced by use of nonclassical photon-number squeezed light. We consider the use of two photon-correlated beams (generated, for example, by spontaneous parametric downconversion) to measure the optical transmittance of an object. The photons of each beam obey a random Poisson process but are synchronized in time. One beam is used to probe the object, and the other is used as a reference providing information on the realization of the random arrival of photons at the object. The additional information available by such measurement may be exploited to improve the accuracy of the measurement. Various estimators, including the maximum-likelihood estimator, are considered, and their performance is evaluated and compared with the measurement based on a single-beam conventional (Poissonian) source and a maximally squeezed (fixed-photon-number) source. The performance advantage that is established depends on parameters such as the intensity of the source, the transmittance of the object, the quantum efficiency of the detectors, the background noise, and the degree of correlation of the photon numbers in the two beams.

Journal of the Optical Society of America A•Feb 1, 1999•28 citations

A practical model of twin-beam experiments for sub-shot-noise absorption measurements

Jason D. Mueller, Nigam Samantaray, Jonathan C. F. Matthews

Quantum-intensity-correlated twin beams of light can be used to measure absorption with precision beyond the classical shot-noise limit. The degree to which this can be achieved with a given estimator is defined by the quality of the twin-beam intensity correlations, which is quantified by the noise reduction factor. We derive an analytical model of twin-beam experiments, incorporating experimental parameters such as the relative detection efficiency of the beams, uncorrelated optical noise, and uncorrelated detector noise. We show that for twin beams without excessive noise, measured correlations can be improved by increasing the detection efficiency of each beam; notwithstanding, this may unbalance detection efficiency. However, for beams with excess intensity or other experimental noise, one should balance detection efficiency, even at the cost of reducing detection efficiency—we specifically define these noise conditions and verify our results with statistical simulation. This has application in design and optimization of absorption spectroscopy and imaging experiments.

arXiv:2006.08438•Applied Physics Letters•Jul 20, 2020•6 citations

Imaging using quantum noise properties of light

Jeremy B. Clark, Zhifan Zhou, Quentin Glorieux +2 more

We show that it is possible to estimate the shape of an object by measuring only the fluctuations of a probing field, allowing us to expose the object to a minimal light intensity. This scheme, based on noise measurements through homodyne detection, is useful in the regime where the number of photons is low enough that direct detection with a photodiode is difficult but high enough such that photon counting is not an option. We generate a few-photon state of multi-spatial-mode vacuum-squeezed twin beams using four-wave mixing and direct one of these twin fields through a binary intensity mask whose shape is to be imaged. Exploiting either the classical fluctuations in a single beam or quantum correlations between the twin beams, we demonstrate that under some conditions quantum correlations can provide an enhancement in sensitivity when estimating the shape of the object.

arXiv:1207.1713•Optics Express•Jul 11, 2012•37 citations

A Note on Quantum Key Channel Efficiency and Security using Correlated Photon Beam Transmitters

Edwards, PJ, W.N. Cheung, H van Pham +3 more

Quantum-correlated photon sources provide a means of suppressing multiple photon emission and thus improving the security and efficiency of quasi single-photon quantum key distribution systems. We present illustrative photon-counting statistics for a Poissonian source conditioned by photon number measurements on a fully correlated twin beam with a non-ideal photon counter. We show that high photon counting efficiency is needed to obtain significant improvement in channel efficiency (bits per symbol) and/or security (in the form of reduced Shannon entropy leakage) over a single beam source.

arXiv:quant-ph/0008013•Aug 3, 2000•0 citations

Absolute efficiency estimation of photon-number-resolving detectors using twin beams

A. P. Worsley, Hendrik B. Coldenstrodt-Ronge, Jeff S. Lundeen +5 more

A nonclassical light source is used to demonstrate experimentally the absolute efficiency calibration of a photon-number-resolving detector. The photon-pair detector calibration method developed by Klyshko for single-photon detectors is generalized to take advantage of the higher dynamic range and additional information provided by photon-number-resolving detectors. This enables the use of brighter twin-beam sources including amplified pulse pumped sources, which increases the relevant signal and provides measurement redundancy, making the calibration more robust.

arXiv:0906.2182•Optics Express•Mar 4, 2009•44 citations

Noise in Classical and Quantum Photon-Correlation Imaging

Bahaa E. A. Saleh, Malvin Carl Teich

Imaging is the estimation of the spatial distribution of a physical object by measuring the optical radiation it emits, or by making use of an optical wave that interacts with the object, via reflection or transmission, for example, before being measured by a detector. The resolution of an imaging system is limited by the inability to localize the optical field at points of the object. Under otherwise ideal conditions, resolution is limited by diffraction. The sensitivity of an imaging system is limited by the uncertainty in the measurement. Under ideal conditions, this is determined by photon noise, which depends on the statistical fluctuations of the light. In conventional imaging systems, an extended detector, such as a CCD camera or an array detector, measures the spatial distribution of the optical intensity, which is proportional to the photon flux density. In interferometric systems, the spatial distribution of the optical field is inferred from measurements of the optical intensity. With the emergence of coherence theory, imaging systems based on measurements of the second-order coherence function at pairs of points in the detection plane were developed. An example is the imaging of an incoherent object based on the van Cittert-Zernike theorem. Imaging systems based on measurement of intensity correlation, or the photon coincidence rate, at pairs of points, were developed in the 1960s. A classic example of the photon-correlation imaging of an object emitting thermal light is stellar imaging using a Hanbury-Brown-Twiss intensity-correlation interferometer. More recently, two-photon light, which may be generated via spontaneous parametric downconversion in a second-order nonlinear optical crystal, has been used for imaging. This type of two-photon (or biphoton) imaging, which has come to be called quantum imaging, is also based on the measurement of photon coincidence by the use of photon-counting array detectors or by scanning two photon-counting detectors at pairs of points. To compare the resolution and sensitivity of imaging systems based on the aforementioned types of measurements, it is necessary to derive expressions for the measured quantities in terms of the object distribution. The point-spread functions based on such expressions can be used to assess the resolution. One measure of the sensitivity of the imaging process is the signal-to-noise ratio (SNR) of the measured variables. The statistical nature of the light source must be known in order to determine the SNR. The purpose of this chapter is to compare the resolution and sensitivity of photon-correlation imaging systems that make use of thermal light and two-photon light. We will henceforth refer to these two imaging modalities as classical and quantum photon-correlation imaging, or simply classical and quantum imaging, respectively. Clearly, light in other quantum states can also be used for imaging.

SPIE eBooks•Mar 16, 2010•4 citations
An estimate of the transmittance of an object is examined in a twin-photon beam setup. The estimate is based on observing both the photons of one beam and the photons of the twin beam after passage through the object. The performance of the estimate (bias, variance, and mean-square error) is compared to the conventional single-beam measurement. The improvement depends on the photon flux, the counting time, the quantum efficiencies of the detectors, and the value of the measured transmittance itself. In general, a performance advantage is achieved for sufficiently high photon flux or long counting time.
The accuracy of optical measurements at low light levels is limited by the quantum noise of the source and by the random nature of the interaction with the measured object. The source noise may be reduced by use of nonclassical photon-number squeezed light. We consider the use of two photon-correlated beams (generated, for example, by spontaneous parametric downconversion) to measure the optical transmittance of an object. The photons of each beam obey a random Poisson process but are synchronized in time. One beam is used to probe the object, and the other is used as a reference providing information on the realization of the random arrival of photons at the object. The additional information available by such measurement may be exploited to improve the accuracy of the measurement. Various estimators, including the maximum-likelihood estimator, are considered, and their performance is evaluated and compared with the measurement based on a single-beam conventional (Poissonian) source and a maximally squeezed (fixed-photon-number) source. The performance advantage that is established depends on parameters such as the intensity of the source, the transmittance of the object, the quantum efficiency of the detectors, the background noise, and the degree of correlation of the photon numbers in the two beams.
Quantum-intensity-correlated twin beams of light can be used to measure absorption with precision beyond the classical shot-noise limit. The degree to which this can be achieved with a given estimator is defined by the quality of the twin-beam intensity correlations, which is quantified by the noise reduction factor. We derive an analytical model of twin-beam experiments, incorporating experimental parameters such as the relative detection efficiency of the beams, uncorrelated optical noise, and uncorrelated detector noise. We show that for twin beams without excessive noise, measured correlations can be improved by increasing the detection efficiency of each beam; notwithstanding, this may unbalance detection efficiency. However, for beams with excess intensity or other experimental noise, one should balance detection efficiency, even at the cost of reducing detection efficiency—we specifically define these noise conditions and verify our results with statistical simulation. This has application in design and optimization of absorption spectroscopy and imaging experiments.
We show that it is possible to estimate the shape of an object by measuring only the fluctuations of a probing field, allowing us to expose the object to a minimal light intensity. This scheme, based on noise measurements through homodyne detection, is useful in the regime where the number of photons is low enough that direct detection with a photodiode is difficult but high enough such that photon counting is not an option. We generate a few-photon state of multi-spatial-mode vacuum-squeezed twin beams using four-wave mixing and direct one of these twin fields through a binary intensity mask whose shape is to be imaged. Exploiting either the classical fluctuations in a single beam or quantum correlations between the twin beams, we demonstrate that under some conditions quantum correlations can provide an enhancement in sensitivity when estimating the shape of the object.
Quantum-correlated photon sources provide a means of suppressing multiple photon emission and thus improving the security and efficiency of quasi single-photon quantum key distribution systems. We present illustrative photon-counting statistics for a Poissonian source conditioned by photon number measurements on a fully correlated twin beam with a non-ideal photon counter. We show that high photon counting efficiency is needed to obtain significant improvement in channel efficiency (bits per symbol) and/or security (in the form of reduced Shannon entropy leakage) over a single beam source.
A nonclassical light source is used to demonstrate experimentally the absolute efficiency calibration of a photon-number-resolving detector. The photon-pair detector calibration method developed by Klyshko for single-photon detectors is generalized to take advantage of the higher dynamic range and additional information provided by photon-number-resolving detectors. This enables the use of brighter twin-beam sources including amplified pulse pumped sources, which increases the relevant signal and provides measurement redundancy, making the calibration more robust.
Imaging is the estimation of the spatial distribution of a physical object by measuring the optical radiation it emits, or by making use of an optical wave that interacts with the object, via reflection or transmission, for example, before being measured by a detector. The resolution of an imaging system is limited by the inability to localize the optical field at points of the object. Under otherwise ideal conditions, resolution is limited by diffraction. The sensitivity of an imaging system is limited by the uncertainty in the measurement. Under ideal conditions, this is determined by photon noise, which depends on the statistical fluctuations of the light. In conventional imaging systems, an extended detector, such as a CCD camera or an array detector, measures the spatial distribution of the optical intensity, which is proportional to the photon flux density. In interferometric systems, the spatial distribution of the optical field is inferred from measurements of the optical intensity. With the emergence of coherence theory, imaging systems based on measurements of the second-order coherence function at pairs of points in the detection plane were developed. An example is the imaging of an incoherent object based on the van Cittert-Zernike theorem. Imaging systems based on measurement of intensity correlation, or the photon coincidence rate, at pairs of points, were developed in the 1960s. A classic example of the photon-correlation imaging of an object emitting thermal light is stellar imaging using a Hanbury-Brown-Twiss intensity-correlation interferometer. More recently, two-photon light, which may be generated via spontaneous parametric downconversion in a second-order nonlinear optical crystal, has been used for imaging. This type of two-photon (or biphoton) imaging, which has come to be called quantum imaging, is also based on the measurement of photon coincidence by the use of photon-counting array detectors or by scanning two photon-counting detectors at pairs of points. To compare the resolution and sensitivity of imaging systems based on the aforementioned types of measurements, it is necessary to derive expressions for the measured quantities in terms of the object distribution. The point-spread functions based on such expressions can be used to assess the resolution. One measure of the sensitivity of the imaging process is the signal-to-noise ratio (SNR) of the measured variables. The statistical nature of the light source must be known in order to determine the SNR. The purpose of this chapter is to compare the resolution and sensitivity of photon-correlation imaging systems that make use of thermal light and two-photon light. We will henceforth refer to these two imaging modalities as classical and quantum photon-correlation imaging, or simply classical and quantum imaging, respectively. Clearly, light in other quantum states can also be used for imaging.