Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

The Rochester Conferences on Coherence and Quantum Optics and the Quantum Information and Measurement meeting

Interaction-free measurements with electrons

Sebastian Thomas, Peter Hommelhoff

Published Jan 1, 2013• 0 citations
Publisher

Abstract

We discuss general features of interaction-free measurements with electrons. In particular, we investigate the effect of semi-transparent samples using a numerical simulation of the Schrödinger equation.
DOI
10.1364/cqo.2013.m6.28

Related papers

Semitransparency in interaction-free measurements

Sebastian Thomas, Christoph Kohstall, Pieter Kruit +1 more

We discuss the effect of semitransparency in a quantum-Zeno-like interaction-free measurement setup, a quantum-physics based approach that might significantly reduce sample damage in imaging and microscopy. With an emphasis on applications in electron microscopy, we simulate the behavior of probe particles in an interaction-free measurement setup with semitransparent samples, and we show that the transparency of a sample can be measured in such a setup. However, such a measurement is not possible without losing (i.e., absorbing or scattering) probe particles in general, which causes sample damage. We show how the amount of lost particles can be minimized by adjusting the number of round trips through the setup, and we explicitly calculate the amount of lost particles in measurements which either aim at distinguishing two transparencies or at measuring an unknown transparency precisely. We also discuss the effect of the sample causing phase shifts in interaction-free measurements. Comparing the resulting loss of probe particles with a classical measurement of transparency, we find that interaction-free measurements only provide a benefit in two cases: first, if two semitransparent samples with a high contrast are to be distinguished, interaction-free measurements lose less particles than classical measurements by a factor that increases with the contrast. This implies that interaction-free measurements with zero loss are possible if one of the samples is perfectly transparent. A second case where interaction-free measurements outperform classical measurements is if three conditions are met: the particle source exhibits Poissonian number statistics, the number of lost particles cannot be measured, and the transparency is larger than approximately $\frac{1}{2}$. In all other cases, interaction-free measurements lose as many probe particles as classical measurements or more. Aside from imaging of gray levels, another possible application for interaction-free measurements is the detection of arbitrarily small phase shifts in transparent samples.

arXiv:1409.0044•Physical Review A•Nov 21, 2014•63 citations

A Quantum Field Theory View of Interaction Free Measurements

Filipe Barroso, Orfeu Bertolami A

arXiv:1911.03339•Foundations of Physics•Jun 30, 2020•1 citation

Free-free experiments: dressed-atom effects during inelastic electron scattering

B. N. Kim, C.M. Weaver, Nicholas L S Martin +1 more

Bulletin of the American Physical Society•Oct 29, 2019•0 citations

Reduced damage in electron microscopy by using interaction-free measurement and conditional reillumination

Akshay Agarwal, Karl K. Berggren, Yuri J. van Staaden +1 more

Interaction-free measurement (IFM) has been proposed as a means of high-resolution, low-damage imaging of radiation-sensitive samples, such as biomolecules and proteins. The basic setup for IFM is a Mach-Zehnder interferometer, and recent progress in nanofabricated electron-diffraction gratings has made it possible to incorporate a Mach-Zehnder interferometer in a transmission electron microscope (TEM). Therefore, the limits of performance of IFM with such an interferometer and a shot-noise limited electron source (such as that in a TEM) are of interest. In this paper, we compare the error probability and sample damage for ideal IFM and classical imaging schemes, through theoretical analysis and numerical simulation. We consider a sample that is either completely transparent or completely opaque at each pixel. In our analysis, we also evaluate the impact of an additional detector for scattered electrons. Inclusion of the scattering detector results in reduction of error by up to an order of magnitude, for both IFM and classical schemes. We also investigate a sample reillumination scheme based on updating priors after each round of illumination and find that this scheme further reduces error. Implementation of these methods is likely achievable with existing instrumentation and would result in improved resolution in low-dose electron microscopy.

arXiv:1901.09702•Physical Review A•Jun 5, 2019•12 citations

On the Feasibility and Usefulness of Applying the Schrödinger Equation to Quantum Measurement

Willem M. de Muynck

arXiv:2312.06735•Jan 1, 2023•0 citations

Electron imaging theory for a quantum resonator

Fu‐Rong Chen, Prof. D. van Dyck

Abstract Reducing radiation damage is becoming a crucial factor in the development of future electron microscopes. The concept of interaction-free imaging utilizing a Mach–Zehnder interferometer has been proposed originally in. 1993 by Elitzur and Vaidman. Using the quantum Zeno effect the quantum efficiency for interaction-free measurements can be increased to near 100 % with increasing number of interrogations provided the sample is a perfect (thick) absorber. However, for an electron beam the sample is in general semi-transparent depending on the thickness. In electron microscopy the interaction-free experiment is complicated by the presence of elastic and inelastic scattering processes in the electron-sample interaction. The ratio of inelastically versus elastically scattered electrons is determined by the nature of the sample and the thickness and cannot be reduced arbitrarily. Because inelastically scattered electrons transfer energy to the sample and cause radiation damage this puts a limit to the elastically scattered electrons and consequently to the resolution of electron imaging. In this paper, the inelastic scattering is modeled as an “absorption” function on the modulus of the electron wave. Image simulations and Argand plots are used to investigate the convergence rate of the Zeno iterations versus different type of samples, in particular a double strained DNA helical sample. It is found that the stronger objects reach maximum quantum efficiency faster than weaker objects for which more interrogations are needed to reach the maximum quantum efficiency. For a general hybrid amplitude/phase object the “phase” information tends to converge to zero as the number of interrogation increases.

Methods in microscopy•Apr 1, 2026•0 citations
We discuss the effect of semitransparency in a quantum-Zeno-like interaction-free measurement setup, a quantum-physics based approach that might significantly reduce sample damage in imaging and microscopy. With an emphasis on applications in electron microscopy, we simulate the behavior of probe particles in an interaction-free measurement setup with semitransparent samples, and we show that the transparency of a sample can be measured in such a setup. However, such a measurement is not possible without losing (i.e., absorbing or scattering) probe particles in general, which causes sample damage. We show how the amount of lost particles can be minimized by adjusting the number of round trips through the setup, and we explicitly calculate the amount of lost particles in measurements which either aim at distinguishing two transparencies or at measuring an unknown transparency precisely. We also discuss the effect of the sample causing phase shifts in interaction-free measurements. Comparing the resulting loss of probe particles with a classical measurement of transparency, we find that interaction-free measurements only provide a benefit in two cases: first, if two semitransparent samples with a high contrast are to be distinguished, interaction-free measurements lose less particles than classical measurements by a factor that increases with the contrast. This implies that interaction-free measurements with zero loss are possible if one of the samples is perfectly transparent. A second case where interaction-free measurements outperform classical measurements is if three conditions are met: the particle source exhibits Poissonian number statistics, the number of lost particles cannot be measured, and the transparency is larger than approximately 12\frac{1}{2}21​. In all other cases, interaction-free measurements lose as many probe particles as classical measurements or more. Aside from imaging of gray levels, another possible application for interaction-free measurements is the detection of arbitrarily small phase shifts in transparent samples.
Interaction-free measurement (IFM) has been proposed as a means of high-resolution, low-damage imaging of radiation-sensitive samples, such as biomolecules and proteins. The basic setup for IFM is a Mach-Zehnder interferometer, and recent progress in nanofabricated electron-diffraction gratings has made it possible to incorporate a Mach-Zehnder interferometer in a transmission electron microscope (TEM). Therefore, the limits of performance of IFM with such an interferometer and a shot-noise limited electron source (such as that in a TEM) are of interest. In this paper, we compare the error probability and sample damage for ideal IFM and classical imaging schemes, through theoretical analysis and numerical simulation. We consider a sample that is either completely transparent or completely opaque at each pixel. In our analysis, we also evaluate the impact of an additional detector for scattered electrons. Inclusion of the scattering detector results in reduction of error by up to an order of magnitude, for both IFM and classical schemes. We also investigate a sample reillumination scheme based on updating priors after each round of illumination and find that this scheme further reduces error. Implementation of these methods is likely achievable with existing instrumentation and would result in improved resolution in low-dose electron microscopy.
Abstract Reducing radiation damage is becoming a crucial factor in the development of future electron microscopes. The concept of interaction-free imaging utilizing a Mach–Zehnder interferometer has been proposed originally in. 1993 by Elitzur and Vaidman. Using the quantum Zeno effect the quantum efficiency for interaction-free measurements can be increased to near 100 % with increasing number of interrogations provided the sample is a perfect (thick) absorber. However, for an electron beam the sample is in general semi-transparent depending on the thickness. In electron microscopy the interaction-free experiment is complicated by the presence of elastic and inelastic scattering processes in the electron-sample interaction. The ratio of inelastically versus elastically scattered electrons is determined by the nature of the sample and the thickness and cannot be reduced arbitrarily. Because inelastically scattered electrons transfer energy to the sample and cause radiation damage this puts a limit to the elastically scattered electrons and consequently to the resolution of electron imaging. In this paper, the inelastic scattering is modeled as an “absorption” function on the modulus of the electron wave. Image simulations and Argand plots are used to investigate the convergence rate of the Zeno iterations versus different type of samples, in particular a double strained DNA helical sample. It is found that the stronger objects reach maximum quantum efficiency faster than weaker objects for which more interrogations are needed to reach the maximum quantum efficiency. For a general hybrid amplitude/phase object the “phase” information tends to converge to zero as the number of interrogation increases.