Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Soviet Journal of Quantum Electronics

Investigation of the amplitude distributions of noise and of signal with noise in a detector with parametric frequency conversion

V S Dugin, I. N. Matveev, S M Pshenichnikov, N. P. Sopina, A F Umnov

Published Sep 30, 1975• 5 citations
Publisher

Abstract

An experimental study was made of the amplitude distributions of noise and of a signal with noise in a detector with parametric frequency conversion. The distributions were quite close to the Poisson law, which confirmed the theoretical assumptions. The results of this study were used to determine the real sensitivity of the detector, which was 2×10−8 W, and the probability false readings and misses, which was 10–3.

DOI
10.1070/qe1975v005n09abeh011985

Related papers

Investigation of the statistical characteristics of spontaneous noise in parametric frequency converters

I. N. Matveev, S M Pshenichnikov, A F Umnov

An experimental investigation was made of the statistical characteristics of spontaneous parametric luminescence generated in the course of parametric frequency up-conversion. It was found that the laws governing the amplitude distribution and the distribution of photocounts of parametric luminescence were nearly of the Poisson type.

Soviet Journal of Quantum Electronics•Nov 30, 1980•0 citations

Measurement of covariance of analog detector readings in the field of spontaneous parametric down-conversion

T. I. Novikova, Kirill A. Kuznetsov, I.V. Korolev +2 more

An approach is considered that can be applied to calibrate detectors operating in the analog signal recording mode. Statistical distributions of the readings of such detectors are studied taking into account fluctuations in the amplitudes of single-photon detector pulses.

International Conference Laser Optics (ICLO)•Jul 1, 2024•0 citations

Quantum noise properties of parametric processes

Colin J. McKinstrie, M. Yu, M. G. Raymer +1 more

In this paper the quantum noise properties of phase-insensitive and phase-sensitive parametric processes are studied. Formulas for the field-quadrature and photon-number means and variances are derived, for processes that involve arbitrary numbers of modes. These quantities determine the signal-to-noise ratios associated with the direct and homo-dyne detection of optical signals. The consequences of the aforementioned formulas are described for frequency conversion, amplification, monitoring, and transmission through sequences of attenuators and amplifiers.

Optics Express•Jan 1, 2005•114 citations

Measurement of amplitude probability distributions for photon-number-operator eigenstates

Bernard Yurke, David Stoler

A homodyne detector measures a field-amplitude component of the incoming signal. If the incoming signal is in an $n$-photon eigenstate the homodyne detector's output probability distribution exhibits $n$ fringes. Here the degree to which the visibility of these fringes is degraded by a homodyne detector with less than unit quantum efficiency is evaluated. An experiment employing conjugate pairs of photons generated via a parametric down conversion or four-wave mixing is proposed by which these fringes could be observed.

Physical Review A•Aug 1, 1987•62 citations

Parametric noise in a nonlinear frequency up-converter of infrared signals by two-photon pumping of 3S–3Dand 3S–5Stransitions in sodium vapor

Yu A Galaĭchuk, Vladimir A. Kudryashov, V. L. Strizhevskiǐ +2 more

A systematic analysis was made of the spectral characteristics of resonance four-photon parametric conversion of infrared radiation as a result of two-photon resonance pumping of the 3S–3D and 3S–5S transitions in sodium and the influence of these characteristics on the threshold sensitivity of a parametric conversion detector was investigated. An experimental study was made of the characteristics of the noise radiation generated as a result of hyperparametric scattering. The results obtained can be used to select the optimal parameters of high-sensitivity detectors of weak infrared signals by parametric conversion in alkali metal vapors.

Soviet Journal of Quantum Electronics•Jul 31, 1985•0 citations

Quantum analysis of intensity fluctuations in the nondegenerate parametric oscillator

Alistair S. Lane, M. D. Reid, Daniel F. Walls

A quantum analysis of the intensity fluctuations is given for the nondegenerate parametric oscillator both above and below threshold. Theoretical analysis and experiments by Heidmann, Horowicz, Reynaud, Giacobino, and Fabre [Phys. Rev. Lett. 59, 2555 (1987)] have shown that a noise suppression below the vacuum level is possible in the difference of the intensities of the signal and idler modes. The effect of nonequal cavity decay rates and intracavity losses is shown to modify significantly the fluctuation spectra for the difference in the intensity of the signal and idler beams. The results of exact nonlinear solutions for the internal cavity modes are discussed. We demonstrate that a very sensitive absorption detector may be made by operating the oscillator near threshold.

Physical Review A•Jul 1, 1988•74 citations
An experimental study was made of the amplitude distributions of noise and of a signal with noise in a detector with parametric frequency conversion. The distributions were quite close to the Poisson law, which confirmed the theoretical assumptions. The results of this study were used to determine the real sensitivity of the detector, which was 2×10−8 W, and the probability false readings and misses, which was 10–3.
In this paper the quantum noise properties of phase-insensitive and phase-sensitive parametric processes are studied. Formulas for the field-quadrature and photon-number means and variances are derived, for processes that involve arbitrary numbers of modes. These quantities determine the signal-to-noise ratios associated with the direct and homo-dyne detection of optical signals. The consequences of the aforementioned formulas are described for frequency conversion, amplification, monitoring, and transmission through sequences of attenuators and amplifiers.
A homodyne detector measures a field-amplitude component of the incoming signal. If the incoming signal is in an nnn-photon eigenstate the homodyne detector's output probability distribution exhibits nnn fringes. Here the degree to which the visibility of these fringes is degraded by a homodyne detector with less than unit quantum efficiency is evaluated. An experiment employing conjugate pairs of photons generated via a parametric down conversion or four-wave mixing is proposed by which these fringes could be observed.
A systematic analysis was made of the spectral characteristics of resonance four-photon parametric conversion of infrared radiation as a result of two-photon resonance pumping of the 3S–3D and 3S–5S transitions in sodium and the influence of these characteristics on the threshold sensitivity of a parametric conversion detector was investigated. An experimental study was made of the characteristics of the noise radiation generated as a result of hyperparametric scattering. The results obtained can be used to select the optimal parameters of high-sensitivity detectors of weak infrared signals by parametric conversion in alkali metal vapors.
A quantum analysis of the intensity fluctuations is given for the nondegenerate parametric oscillator both above and below threshold. Theoretical analysis and experiments by Heidmann, Horowicz, Reynaud, Giacobino, and Fabre [Phys. Rev. Lett. 59, 2555 (1987)] have shown that a noise suppression below the vacuum level is possible in the difference of the intensities of the signal and idler modes. The effect of nonequal cavity decay rates and intracavity losses is shown to modify significantly the fluctuation spectra for the difference in the intensity of the signal and idler beams. The results of exact nonlinear solutions for the internal cavity modes are discussed. We demonstrate that a very sensitive absorption detector may be made by operating the oscillator near threshold.